Circuit Breaker VL800N

Showing 21-34 of 34 Products

3VL6780-1NF46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL800N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU20, LSI In=800A, rated current IR=320...800A, overload protection, ISD=1.5 to 7 xIR, II=8 xIN short-circuit protection N protected ETU communication-capable

3VL6780-1NF46-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL800N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU20, LSI In=800A, rated current IR=320...800A, overload protection, ISD=1.5 to 7 xIR, II=8 xIN short-circuit protection N protected without auxiliary release ETU communication-capable

3VL6780-1NH46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL800N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU22, LSIG In=800A, rated current IR=320...800A, overload protection, ISD=1.5 to 7 xIR, II=8 xIN short-circuit protection N protected ETU communication-capable

3VL6780-1NH46-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL800N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU22, LSIG In=800A, rated current IR=320...800A, overload protection, ISD=1.5 to 7 xIR, II=8 xIN short-circuit protection N protected without auxiliary release ETU communication-capable

3VL6780-1NN46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL800N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU12, LIG In=800A, rated current IR=320...800A, overload protection, II=1.25 to 8 xIN, short-circuit protection N protected ETU communication-capable

3VL6780-1NN46-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL800N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU12, LIG In=800A, rated current IR=320...800A, overload protection, II=1.25 to 8 xIN, short-circuit protection N protected without auxiliary release ETU communication-capable

3VL6780-1TA46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL800N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU10, LIN In=800A, rated current IR=320...800A, overload protection, II=1.25 to 8 xIN, short-circuit protection N protected

3VL6780-1TB46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL800N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU10, LI In=800A, rated current IR=320...800A, overload protection, II=1.25 to 8 xIN, short-circuit protection

3VL6780-1TE46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL800N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU20, LSI In=800A, rated current IR=320...800A, overload protection, ISD=1.5 to 7 xIR, II=8 xIN short-circuit protection N unprotected

3VL6780-1TF46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL800N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU20, LSI In=800A, rated current IR=320...800A, overload protection, ISD=1.5 to 7 xIR, II=8 xIN short-circuit protection N protected

3VL6780-1TH46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL800N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU22, LSIG In=800A, rated current IR=320...800A, overload protection, ISD=1.5 to 7 xIR, II=8 xIN short-circuit protection N protected

3VL6780-1TN46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL800N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU12, LIG In=800A, rated current IR=320...800A, overload protection, II=1.25 to 8 xIN, short-circuit protection N protected

3VL6780-1UJ46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL800N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit LCD ETU40, LI/LS/LSI In=800A, rated current IR=320...800A, overload protection, ISD=1.5 to 7 xIR, II=8 xIN short-circuit protection N protected

3VL6780-1UN46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL800N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit LCD ETU42, LSIG In=800A, rated current IR=320...800A, overload protection, ISD=1.5 to 7 xIR, II=8 xIN short-circuit protection N protected with ground-fault protection