[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL800L w/o Electronic Trip Unit very high breaking capacity Icu=100kA/415V AC, 4-pole In=< 800A, rated current without auxiliary release with screw terminal connections for switching unit and ETU
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 800L VERY HIGH SWITCHING CAPACITY ICU=100KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU10, LI IN=800A, RATED CURRENT IR=320-800A, OVERLOAD II=1,25TO8XIN, SHORT-CIRCUIT N PROTECTED
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 800L VERY HIGH SWITCHING CAPACITY ICU=100KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU10, LI IN=800A, RATED CURRENT IR=320-800A, OVERLOAD II=1,25TO8XIN, SHORT-CIRCUIT N NOT PROTECTED
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 800L VERY HIGH SWITCHING CAPACITY ICU=100KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU12, LIG IN=800A, RATED CURRENT IR=320-800A, OVERLOAD II=1,25TO8XIN, SHORT-CIRCUIT N NOT PROTECTED
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 800L VERY HIGH SWITCHING CAPACITY ICU=100KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU12, LIG IN=800A, RATED CURRENT IR=320-800A, OVERLOAD II=1,25TO8XIN, SHORT-CIRCUIT N PROTECTED
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 800L VERY HIGH SWITCHING CAPACITY ICU=100KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU20, LSI IN=800A, RATED CURRENT IR=320-800A, OVERLOAD ISD=1,5TO7XIR, II=8XIN SHORT-CIRCUIT N NOT PROTECTED
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 800L VERY HIGH SWITCHING CAPACITY ICU=100KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU20, LSI IN=800A, RATED CURRENT IR=320-800A, OVERLOAD ISD=1,5TO7XIR, II=8XIN SHORT-CIRCUIT N PROTECTED
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 800L VERY HIGH SWITCHING CAPACITY ICU=100KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG IN=800A, RATED CURRENT IR=320-800A, OVERLOAD ISD=1,5TO7XIR, II=8XIN SHORT-CIRCUIT N NOT PROTECTED
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 800L VERY HIGH SWITCHING CAPACITY ICU=100KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG IN=800A, RATED CURRENT IR=320-800A, OVERLOAD ISD=1,5TO7XIR, II=8XIN SHORT-CIRCUIT N PROTECTED
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL800L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection trip unit LCD ETU40, LI/LS/LSI In=800A, rated current IR=320...800A, overload protection, ISD=1.5 to 7 xIR, II=8 xIN short-circuit protection N protected
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL800L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection trip unit LCD ETU42, LSIG In=800A, rated current IR=320-800A, overload protection, ISD=1.5 to 7 xIR, II=8 xIN short-circuit protection N protected with ground-fault protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL800L very high breaking capacity Icu=100kA, 415V AC 4-pole, non-auto. air circ. br. trip unit magnetic In=800A, rated current II=6500A, short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL800L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection trip unit ETU10, LI In=800A, rated current IR=320...800A, overload protection, II=1.25 to 8 xIN, short-circuit protection N protected shipbuilding certificate for LRS, DNV and gL
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL800L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection trip unit ETU20, LSI In=800A, rated current IR=320...800A, overload protection, ISD=1.5 to 7 xIR, II=8 xIN short-circuit protection N protected shipbuilding certificate for LRS, DNV and gL
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL800L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection trip unit ETU10, LIN In=800A, rated current IR=320...800A, overload protection, II=1.25 to 8 xIN, short-circuit protection N protected ETU communication-capable
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL800L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection trip unit ETU10, LIN In=800A, rated current IR=320...800A, overload protection, II=1.25 to 8 xIN, short-circuit protection N protected without auxiliary release ETU communication-capable
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL800L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection trip unit ETU10, LI In=800A, rated current IR=320...800A, overload protection, II=1.25 to 8 xIN, short-circuit protection ETU communication-capable
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL800L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection trip unit ETU10, LI In=800A, rated current IR=320...800A, overload protection, II=1.25 to 8 xIN, short-circuit protection without auxiliary release ETU communication-capable
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL800L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection trip unit ETU20, LSI In=800A, rated current IR=320...800A, overload protection, ISD=1.5 to 7 xIR, II=8 xIN short-circuit protection ETU communication-capable
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL800L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection trip unit ETU20, LSI In=800A, rated current IR=320...800A, overload protection, ISD=1.5 to 7 xIR, II=8 xIN short-circuit protection without auxiliary release ETU communication-capable