Circuit Breaker VL800 UL

Showing 61-80 of 94 Products

3VL6180-2GD30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 800 UL; TYPE MG (CAT NO. HMX3X800) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 800A, RATED CURRENT II= 1.25 TO 8 X IN, SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL6180-2GE30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 800 UL; TYPE MG (CAT NO. HMX3P800) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LSI TU= 40 DEGR. CELSIUS IN= 800A, RATED CURRENT ISD=1.5 TO 7 X IR, II=8 X IN SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL6180-2GH30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 800 UL; TYPE MG (CAT NO. HMX3U800) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 800A, RATED CURRENT ISD=1.5 TO 7 X IR, II=8 X IN SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL6180-2JH30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 800 UL; TYPE MG (CAT NO. HMX3D800) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 800A, RATED CURRENT ISD=1.25 TO 10 X IR, II=8X IN SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL6180-2JM30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 800 UL; TYPE MG (CAT NO. HMX3E800) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 800A, RATED CURRENT ISD=1.25 TO 10 X IR, II=8 X IN SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL6180-2KE30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL800 UL; type MG (cat no. HMS3S800) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case switch) trip unit magnetic TA=40?C In=< 800A, rated current II=6500A short-circuit protection non-auto. air circuit breaker without connection accessories

3VL6180-2KK30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL800 UL; type MG (cat no. HMM3M800) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (motor starter protector) trip unit magnetic TA=40?C In=< 800A, rated current II=3250..6500A short-circuit protection starter combination without connection accessories

3VL6180-2KN30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL800 UL; type MG (cat no. HMX3B800) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case circuit breaker) trip unit TM, LI TA=40?C In=< 800A, rated current II=3250...6500A short-circuit protection IR=800A ETU for line protection without connection accessories

3VL6180-2PB30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL800 UL; type MG (cat no. HMX3R800) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case circuit breaker) trip unit ETU, LI TA=40?C In=800A, rated current II=1.25 to 8 xIN, short-circuit protection IR=300-800A ETU for line protection without connection accessories

3VL6180-2PD30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL800 UL; type MG (cat no. HMX3W800) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case circuit breaker) trip unit ETU, LIG TA=40?C 3 phases/4 lines In=800A, rated current II=1.25 to 8 xIN, short-circuit protection IR=300-800A ETU for line protection without connection accessories

3VL6180-2PE30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL800 UL; type MG (cat no. HMX3T800) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case circuit breaker) trip unit ETU, LSI TA=40?C In=800A, rated current ISD=1.5 to 7 xIR, II=8 xIN short-circuit protection IR=300-800A ETU for line protection without connection accessories

3VL6180-2PH30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL800 UL; type MG (cat no. HMX3V800) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case circuit breaker) trip unit ETU, LSIG TA=40?C 3 phases/4 lines In=800A, rated current ISD=1.5 to 7 xIR, II=8 xIN short-circuit protection IR=300-800A ETU for line protection without connection accessories

3VL6180-2VH30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL800 UL type MG (cat no. HMX3A800) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole; NEMA rating 65kA/480V and 35kA/600V (molded case circuit breaker) trip unit LCD ETU, LI/LS/LSI TA=40?C In=800A, rated current ISD=1.25-10xIR, II=8xIN short-circuit protection IR=300-800A ETU for line protection

3VL6180-2VJ30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL800 UL type MG (cat no. HMX3K800) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole; NEMA rating 65kA/480V and 35kA/600V (molded case circuit breaker) trip unit LCD ETU, LSIG-G with alarm TA=40?C 3 phases/4 lines In=800A, rated current ISD=1.25-10xIR, II=8xIN short-circuit protection IR=300-800A ETU for line protection

3VL6180-2VM30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL800 UL type MG (cat no. HMX3G800) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole; NEMA rating 65kA/480V and 35kA/600V (molded case circuit breaker) trip unit LCD ETU, LSIG TA=40?C 3 phases/4 lines In=800A, rated current ISD=1.25-10xIR, II=8xIN short-circuit protection IR=300-800A ETU for line protection

3VL6180-3GB30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 800 UL; TYPE MG (CAT NO. LMX3N800) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 100KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LI TU= 40 DEGR. CELSIUS IN= 800A, RATED CURRENT II= 1.25 TO 8 X IN, SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL6180-3GD30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 800 UL; TYPE MG (CAT NO. LMX3X800) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 100KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 800A, RATED CURRENT II= 1.25 TO 8 X IN, SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL6180-3GE30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 800 UL; TYPE MG (CAT NO. LMX3P800) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 100KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LSI TU= 40 DEGR. CELSIUS IN= 800A, RATED CURRENT ISD=1.5 TO 7 X IR, II=8 X IN SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL6180-3GH30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 800 UL; TYPE MG (CAT NO. LMX3U800) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 100KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 800A, RATED CURRENT ISD=1.5 TO 7 X IR, II=8 X IN SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL6180-3JH30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 800 UL; TYPE MG (CAT NO. LMX3D800) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 100KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 800A, RATED CURRENT ISD=1.25 TO 10 X IR, II=8 X IN SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES