[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU12, LIG 3 phases/4 lines In=400A, rated current IR=160...400A, overload protection, II=1.25 to 11xIN, short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU22, LSIG 3 phases/3 lines In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU22, LSIG 3 phases/4 lines with connecting cable In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU12, LIG 3 phases/3 lines In=400A, rated current IR=160...400A, overload protection, II=1.25 to 11xIN, short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit LCD ETU40, LI/LS/LSI In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit LCD ETU40, LI/LS/LSI In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection without auxiliary release
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit LCD ETU42, LSIG 3 phases/3 lines In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit LCD ETU42, LSIG 3 phases/3 lines In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection without auxiliary release
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit LCD ETU42, LSIG 3 phases/4 lines with connecting cable In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit LCD ETU42, LSIG 3 phases/4 lines with connecting cable In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection without auxiliary release
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL800H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit LCD ETU40, LI/LS/LSI In=800A, rated current IR=320...800A, overload protection, ISD=1.5 to 7 xIR, II=8 xIN short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL800H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit LCD ETU40, LI/LS/LSI In=800A, rated current IR=320...800A, overload protection, ISD=1.5 to 7 xIR, II=8 xIN short-circuit protection without auxiliary release
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL800H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit LCD ETU42, LSIG 3 phases/3 lines In=800A, rated current IR=320...800A, overload protection, ISD=1.5 to 7xIR, II=8XIN short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL800H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit LCD ETU42, LSIG 3 phases/3 lines In=800A, rated current IR=320...800A, overload protection, ISD=1.5 to 7xIR, II=8XIN short-circuit protection without auxiliary release
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL800H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit LCD ETU42, LSIG 3 phases/4 lines with connecting cable In=800A, rated current IR=320...800A, overload protection, ISD=1.5 to 7xIR, II=9XIN short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL800H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit LCD ETU42, LSIG 3 phases/4 lines with connecting cable In=800A, rated current IR=320...800A, overload protection, ISD=1.5 to 7xIR, II=9XIN short-circuit protection without auxiliary release
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit LCD ETU40, LI/LS/LSI In=1600A, rated current IR=640...1600A, overload protection, ISD=1.5 to 8 xIR, II=9 xIN short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit LCD ETU40, LI/LS/LSI In=1600A, rated current IR=640...1600A, overload protection, ISD=1.5 to 8 xIR, II=9 xIN short-circuit protection without auxiliary release
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit LCD ETU42, LSIG 3 phases/3 lines In=1600A, rated current IR=640...1600A, overload protection, ISD=1.5 to 8xIR, II=9XIN short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit LCD ETU42, LSIG 3 phases/3 lines In=1600A, rated current IR=640...1600A, overload protection, ISD=1.5 to 8xIR, II=9XIN short-circuit protection without auxiliary release