Circuit Breaker VL400 UL

Showing 61-80 of 94 Products

3VL4140-1VJ30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400 UL type JG (cat no. NJX3K400) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35kA/480V and 25kA/600V (molded case circuit breaker) Electronic Trip Unit LCD ETU, LSIG-G with alarm TA=40?C 3 phases/4 lines In=400A, rated current ISD=1.25-10xIR, II=11X in short-circuit protection IR=150-400A ETU for line protection

3VL4140-1VM30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400 UL type JG (cat no. NJX3G400) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35kA/480V and 25kA/600V (molded case circuit breaker) Electronic Trip Unit LCD ETU, LSIG TA=40?C 3 phases/4 lines In=400A, rated current ISD=1.25-10xIR, II=11X in short-circuit protection IR=150-400A ETU for line protection

3VL4140-2GB30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400 UL; TYPE JG (CAT NO. HJX3N400) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LI TU= 40 DEGR. CELSIUS IN= 400A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 150-400A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL4140-2GD30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400 UL; TYPE JG (CAT NO. HJX3X400) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 400A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 150-400A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL4140-2GE30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400 UL; TYPE JG (CAT NO. HJX3P400) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LSI TU= 40 DEGR. CELSIUS IN= 400A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 150-400A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL4140-2GH30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400 UL; TYPE JG (CAT NO. HJX3U400) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 400A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 150-400A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL4140-2JH30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400 UL; TYPE JG (CAT NO. HJX3D400) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 400A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 150-400A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL4140-2JM30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400 UL; TYPE JG (CAT NO. HJX3E400) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 400A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 150-400A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL4140-2KE30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400 UL; type JG (cat no. HJS3S400) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case switch) Electronic Trip Unit magnetic TA=40?C In=< 400A, rated current II=4400A short-circuit protection non-auto. air circuit breaker without connection accessories

3VL4140-2KJ30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400 UL; type JG (cat no. HJM3L400L) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (motor starter protector) Electronic Trip Unit magnetic TA=40?C In=< 400A, rated current II=1250..2500A short-circuit protection starter combination without connection accessories

3VL4140-2KK30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400 UL; type JG (cat no. HJM3M400) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (motor starter protector) Electronic Trip Unit magnetic TA=40?C In=< 400A, rated current II=2000..4000A short-circuit protection starter combination without connection accessories

3VL4140-2KN30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400 UL; type JG (cat no. HJX3B400) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case circuit breaker) Electronic Trip Unit TM, LI TA=40?C In=< 400A, rated current II=2000..4000A short-circuit protection IR=400A Electronic Trip Unit for line protection without connection accessories

3VL4140-2PB30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400 UL; type JG (cat no. HJX3R400) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case circuit breaker) Electronic Trip Unit ETU, LI TA=40?C In=400A, rated current II=1.25 to 11xIN, short-circuit protection IR=150-400A ETU for line protection without connection accessories

3VL4140-2PD30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400 UL; type JG (cat no. HJX3W400) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case circuit breaker) Electronic Trip Unit ETU, LIG TA=40?C 3 phases/4 lines In=400A, rated current II=1.25 to 11xIN, short-circuit protection IR=150-400A ETU for line protection without connection accessories

3VL4140-2PE30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400 UL; type JG (cat no. HJX3T400) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case circuit breaker) Electronic Trip Unit ETU, LSI TA=40?C In=400A, rated current ISD=1.5 to 10xIR, II=11X in short-circuit protection IR=200-400A ETU for line protection without connection accessories

3VL4140-2PH30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400 UL; type JG (cat no. HJX3V400) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case circuit breaker) Electronic Trip Unit ETU, LSIG TA=40?C 3 phases/4 lines In=400A, rated current ISD=1.5 to 10xIR, II=11X in short-circuit protection IR=200-400A ETU for line protection without connection accessories

3VL4140-2VH30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400 UL type JG (cat no. HJX3A400) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole; NEMA rating 65kA/480V and 25kA/600V (molded case circuit breaker) Electronic Trip Unit LCD ETU, LI/LS/LSI TA=40?C In=400A, rated current ISD=1.25-10xIR, II=11X in short-circuit protection IR=150-400A ETU for line protection

3VL4140-2VJ30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400 UL type JG (cat no. HJX3K400) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole; NEMA rating 65kA/480V and 25kA/600V (molded case circuit breaker) Electronic Trip Unit LCD ETU, LSIG-G with alarm TA=40?C 3 phases/4 lines In=400A, rated current ISD=1.25-10xIR, II=11X in short-circuit protection IR=150-400A ETU for line protection

3VL4140-2VM30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400 UL type JG (cat no. HJX3G400) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole; NEMA rating 65kA/480V and 25kA/600V (molded case circuit breaker) Electronic Trip Unit LCD ETU, LSIG TA=40?C 3 phases/4 lines In=400A, rated current ISD=1.25-10xIR, II=11X in short-circuit protection IR=150-400A ETU for line protection

3VL4140-3GB30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400 UL; TYPE JG (CAT NO. LJX3N400) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 100KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LI TU= 40 DEGR. CELSIUS IN= 400A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 150-400A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES