• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.

Circuit Breaker VL160X

Showing 81-100 of 102 Products

3VL1716-1DA36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit TM, LI In=160A, rated current Ir=160A, overload protection II=1500A, short-circuit prot. with screw terminals

3VL1716-1DD33-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit TM, LI In=160A, rated current Ir=125...160A, overload prot. II=1500A, short-circuit prot.

3VL1716-1DD36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit TM, LI In=160A, rated current Ir=125...160A, overload prot. II=1500A, short-circuit prot. with screw terminals

3VL1716-1DE33-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 3-pole, non-auto. air circ. br. Electronic Trip Unit magnetic In=160A, rated current II=1800A, short-circuit prot.

3VL1716-1DE36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 3-pole, non-auto. air circ. br. Electronic Trip Unit magnetic In=160A, rated current II=1800A, short-circuit prot. with screw terminals

3VL1716-2DA33-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Electronic Trip Unit TM, LI In=160A, rated current Ir=160A, overload protection II=1500A, short-circuit prot.

3VL1716-2DA36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Electronic Trip Unit TM, LI In=160A, rated current Ir=160A, overload protection II=1500A, short-circuit prot. with screw terminals

3VL1716-2DD33-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Electronic Trip Unit TM, LI In=160A, rated current Ir=125...160A, overload prot. II=1500A, short-circuit prot.

3VL1716-2DD33-0AG1

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL160X H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=160A, RATED CURRENT IR=125-160A, OVERLOAD II=1500A, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE ALARM SWITCH KIT 1AS(1NO OR 1NC)

3VL1716-2DD36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Electronic Trip Unit TM, LI In=160A, rated current Ir=125...160A, overload prot. II=1500A, short-circuit prot. with screw terminals

3VL1716-2DE33-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 3-pole, non-auto. air circ. br. Electronic Trip Unit magnetic In=160A, rated current II=1800A, short-circuit prot.

3VL1716-2DE36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 3-pole, non-auto. air circ. br. Electronic Trip Unit magnetic In=160A, rated current II=1800A, short-circuit prot. with screw terminals

3VL1725-1DA33-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit TM, LI In=25A, rated current Ir=25A, overload protection II=300A, short-circuit prot.

3VL1725-1DA36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit TM, LI In=25A, rated current Ir=25A, overload protection II=300A, short-circuit prot. with screw terminals

3VL1725-2DA33-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Electronic Trip Unit TM, LI In=25A, rated current Ir=25A, overload protection II=300A, short-circuit prot.

3VL1725-2DA36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Electronic Trip Unit TM, LI In=25A, rated current Ir=25A, overload protection II=300A, short-circuit prot. with screw terminals

3VL1796-1DA33-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit TM, LI In=16A, rated current Ir=16A, overload protection II=300A, short-circuit prot.

3VL1796-1DA36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit TM, LI In=16A, rated current Ir=16A, overload protection II=300A, short-circuit prot. with screw terminals

3VL1796-2DA33-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Electronic Trip Unit TM, LI In=16A, rated current Ir=16A, overload protection II=300A, short-circuit prot.

3VL1796-2DA36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Electronic Trip Unit TM, LI In=16A, rated current Ir=16A, overload protection II=300A, short-circuit prot. with screw terminals