[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Electronic Trip Unit TM, LI In=160A, rated current Ir=160A, overload protection II=1500A, short-circuit prot. N unprotected
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Electronic Trip Unit TM, LI In=160A, rated current Ir=160A, overload protection II=1500A, short-circuit prot. N unprotected with screw terminals
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit, TM, LI In=160A, rated current Ir=160A, overload protection II=1500A, short-circuit protection N protected (100%)
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit, TM, LI In=160A, rated current Ir=160A, overload protection II=1500A, short-circuit protection N protected (100%) with screw terminals
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Electronic Trip Unit TM, LI In=160A, rated current Ir=160A, overload protection II=1500A, short-circuit prot. N protected
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Electronic Trip Unit TM, LI In=160A, rated current Ir=160A, overload protection II=1500A, short-circuit prot. N protected with screw terminals
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 4-pole, non-auto. air circ. br. Electronic Trip Unit magnetic In=160A, rated current II=1800A, short-circuit prot.
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 4-pole, non-auto. air circ. br. Electronic Trip Unit magnetic In=160A, rated current II=1800A, short-circuit prot. with screw terminals
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Electronic Trip Unit TM, LI In=160A, rated current Ir=160A, overload protection II=1500A, short-circuit prot. N unprotected
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Electronic Trip Unit TM, LI In=160A, rated current Ir=160A, overload protection II=1500A, short-circuit prot. N unprotected with screw terminals
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit, TM, LI In=160A, rated current Ir=160A, overload protection II=1500A, short-circuit protection N protected (100%)
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit, TM, LI In=160A, rated current Ir=160A, overload protection II=1500A, short-circuit protection N protected (100%) with screw terminals
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Electronic Trip Unit TM, LI In=25A, rated current Ir=25A, overload protection II=300A, short-circuit prot. N protected
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Electronic Trip Unit TM, LI In=25A, rated current Ir=25A, overload protection II=300A, short-circuit prot. N protected with screw terminals
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Electronic Trip Unit TM, LI In=25A, rated current Ir=25A, overload protection II=300A, short-circuit prot. N unprotected
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Electronic Trip Unit TM, LI In=25A, rated current Ir=25A, overload protection II=300A, short-circuit prot. N unprotected with screw terminals
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Electronic Trip Unit TM, LI In=25A, rated current Ir=25A, overload protection II=300A, short-circuit prot. N protected
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Electronic Trip Unit TM, LI In=25A, rated current Ir=25A, overload protection II=300A, short-circuit prot. N protected with screw terminals
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Electronic Trip Unit TM, LI In=25A, rated current Ir=25A, overload protection II=300A, short-circuit prot. N unprotected
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Electronic Trip Unit TM, LI In=25A, rated current Ir=25A, overload protection II=300A, short-circuit prot. N unprotected with screw terminals