• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.

Circuit Breaker VL160L

Showing 41-60 of 298 Products

3VL2706-3ML36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU12, LIG 3 phases/3 lines In=63A, rated current IR=25...63A, overload protection, II=1.25 to 11xIN, short-circuit protection with screw terminals ETU communication-capable

3VL2706-3ML36-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU12, LIG 3 phases/3 lines In=63A, rated current IR=25...63A, overload protection, II=1.25 to 11xIN, short-circuit protection with screw terminals without auxiliary release ETU communication-capable

3VL2706-3MP33-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 3-pole, motor/generator prot. Electronic Trip Unit ETU10M, LI In=63A, rated current IR=25...63A, overload protection, II=1.25 to 11xIN, short-circuit protection ETU communication-capable

3VL2706-3MP33-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 3-pole, motor/generator prot. Electronic Trip Unit ETU10M, LI In=63A, rated current IR=25...63A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release ETU communication-capable

3VL2706-3MP36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 3-pole, motor/generator prot. Electronic Trip Unit ETU10M, LI In=63A, rated current IR=25...63A, overload protection, II=1.25 to 11xIN, short-circuit protection with screw terminals ETU communication-capable

3VL2706-3MP36-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 3-pole, motor/generator prot. Electronic Trip Unit ETU10M, LI In=63A, rated current IR=25...63A, overload protection, II=1.25 to 11xIN, short-circuit protection with screw terminals without auxiliary release ETU communication-capable

3VL2706-3MS33-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 3-pole, motor protection Electronic Trip Unit ETU30M, LI Ir=25...63A, overload prot., TC=10A...30, II=6/8/11 xIN, short-circuit protection ETU communication-capable

3VL2706-3MS33-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 3-pole, motor protection Electronic Trip Unit ETU30M, LI Ir=25...63A, overload prot., TC=10A...30, II=6/8/11 xIN, short-circuit protection without auxiliary release ETU communication-capable

3VL2706-3MS36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 3-pole, motor protection Electronic Trip Unit ETU30M, LI Ir=25...63A, overload prot., TC=10A...30, II=6/8/11 xIN, short-circuit protection with screw terminals ETU communication-capable

3VL2706-3MS36-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 3-pole, motor protection Electronic Trip Unit ETU30M, LI Ir=25...63A, overload prot., TC=10A...30, II=6/8/11 xIN, short-circuit protection with screw terminals without auxiliary release ETU communication-capable

3VL2706-3SB33-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU10, LI In=63A, rated current IR=25...63A, overload protection, II=1.25 to 11xIN, short-circuit protection

3VL2706-3SB33-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU10, LI In=63A, rated current IR=25...63A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release

3VL2706-3SB36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU10, LI In=63A, rated current IR=25...63A, overload protection, II=1.25 to 11xIN, short-circuit protection with screw terminals

3VL2706-3SB36-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU10, LI In=63A, rated current IR=25...63A, overload protection, II=1.25 to 11xIN, short-circuit protection with screw terminals without auxiliary release

3VL2706-3SE33-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU20, LSI In=63A, rated current IR=25...63A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection

3VL2706-3SE33-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU20, LSI In=63A, rated current IR=25...63A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection without auxiliary release

3VL2706-3SE36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU20, LSI In=63A, rated current IR=25...63A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection with screw terminals

3VL2706-3SE36-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU20, LSI In=63A, rated current IR=25...63A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection with screw terminals without auxiliary release

3VL2706-3SF33-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU12, LIG 3 phases/4 lines In=63A, rated current IR=25...63A, overload protection, II=1.25 to 11xIN, short-circuit protection

3VL2706-3SF33-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU12, LIG 3 phases/4 lines In=63A, rated current IR=25...63A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release