[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Electronic Trip Unit LCD ETU40, LI/LS/LSI In=63A, rated current IR=25...63A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Electronic Trip Unit LCD ETU40, LI/LS/LSI In=63A, rated current IR=25...63A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected without auxiliary release
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Electronic Trip Unit LCD ETU40, LI/LS/LSI In=63A, rated current IR=25...63A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected with screw terminals
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Electronic Trip Unit LCD ETU40, LI/LS/LSI In=63A, rated current IR=25...63A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected with screw terminals without auxiliary release
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Electronic Trip Unit LCD ETU42, LSIG In=63A, rated current IR=25...63A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected with ground-fault protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Electronic Trip Unit LCD ETU42, LSIG In=63A, rated current IR=25...63A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected with ground-fault protection without auxiliary release
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Electronic Trip Unit LCD ETU42, LSIG In=63A, rated current IR=25...63A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected with screw terminals
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Electronic Trip Unit LCD ETU42, LSIG In=63A, rated current IR=25...63A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected with screw terminals without auxiliary release
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=63A, RATED CURRENT IR=50-63A, OVERLOAD II=300-600A, SHORT CIRCUIT N PROTECTED
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU= 70 KA, 415 V AC 4-POLE, SYSTEM PROTECTION OVERCURRENT RELEASE TM, LI IN= 63 A, RATED CURRENT IR= 50...63 A, OVERLOAD PROT. II= 300...600 A, SHORT-CIRCUIT PROT. N PROTECTED WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU= 70 KA, 415 V AC 4-POLE, SYSTEM PROTECTION OVERCURRENT RELEASE TM, LI IN= 63 A, RATED CURRENT IR= 50...63 A, OVERLOAD PROTECTION, II= 300...600 A, SHORT-CIRCUIT PROTECTION N PROTECTED WITHOUT AUXILIARY RELEASE AUXILIARY SWITCH KIT 2 AUX. SWITCHES (1NO+1NC)
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=63A, RATED CURRENT IR=50-63A, OVERLOAD II=300-600A, SHORT CIRCUIT N PROTECTED WITH SCREW CONNECTION
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU= 70 KA, 415 V AC 4-POLE, SYSTEM PROTECTION OVERCURRENT RELEASE TM, LI IN= 63 A, RATED CURRENT IR= 50...63 A, OVERLOAD PROT. II= 300...600 A, SHORT-CIRCUIT PROT. II= 300...600 A, WITH SCREW CONNECTION WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Electronic Trip Unit TM, LI In=63A, rated current IR=50...63A, overload protection, II=300...600A, short-circuit protection N unprotected
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Electronic Trip Unit TM, LI In=63A, rated current IR=50...63A, overload protection, II=300...600A, short-circuit protection N unprotected with screw terminals
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Electronic Trip Unit TM, LI In=63A, rated current IR=50...63A, overload protection, II=300...600A, short-circuit protection N protected
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Electronic Trip Unit TM, LI In=63A, rated current IR=50...63A, overload protection, II=300...600A, short-circuit protection N protected with screw terminals
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Electronic Trip Unit ETU10, LI In=63A, rated current IR=25...63A, overload protection, II=1.25 to 11xIN, short-circuit protection N protected shipbuilding certificate for LRS, DNV and gL
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Electronic Trip Unit ETU10, LI In=63A, rated current IR=25...63A, overload protection, II=1.25 to 11xIN, short-circuit protection N protected without auxiliary release shipbuilding certificate for LRS, DNV and gL
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Electronic Trip Unit ETU10, LI In=63A, rated current IR=25...63A, overload protection, II=1.25 to 11xIN, short-circuit protection N protected with screw terminals shipbuilding certificate for LRS, DNV and gL