[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1600 UL type PG (cat no. LPX3K120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole; NEMA rating 100kA/480V and 65kA/600V (molded case circuit breaker) trip unit LCD ETU, LSIG-G with alarm TA=40?C 3 phases/4 lines In=1200A, rated current ISD=1.25-10xIR, II=10xIN short-circuit protection IR=400-1200A overcurrent rel. for line protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1600 UL type PG (cat no. LPX3G120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole; NEMA rating 100kA/480V and 65kA/600V (molded case circuit breaker) trip unit LCD ETU, LSIG TA=40?C 3 phases/4 lines In=1200A, rated current ISD=1.25-10xIR, II=10xIN short-circuit protection IR=400-1200A overcurrent rel. for line protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1600 UL; type PG (cat no. NPX3B140) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole, NEMA rating 35kA/480V, (molded case circuit breaker) trip unit TM, LI TA=40?C In=< 1400A, rated current II=7000...12000A short-circuit protection IR=1400A ETU for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1600 UL; type PG (cat no. HPX3B140) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case circuit breaker) trip unit TM, LI TA=40?C In=< 1400A, rated current II=7000...12000A short-circuit protection IR=1400A ETU for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1600 UL; type PG (cat no. LPX3B140) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole, NEMA rating 100kA/480V, (molded case circuit breaker) trip unit TM, LI TA=40?C In=< 1400A, rated current II=7000...12000A short-circuit protection IR=1400A ETU for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 1600 UL; TYPE PG (CAT NO. NPX3N160) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD BREAKING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LI TU= 40 DEGR. CELSIUS IN= 1600A, RATED CURRENT II= 1.25 TO 6 X IN, SHORT-CIRCUIT PROTECTION IR= 700-1600A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 1600 UL; TYPE PG (CAT NO. NPX3X160) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD BREAKING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 1600A, RATED CURRENT II= 1.25 TO 6 X IN, SHORT-CIRCUIT PROTECTION IR= 700-1600A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 1600 UL; TYPE PG (CAT NO. NPX3P160) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD BREAKING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LSI TU= 40 DEGR. CELSIUS IN= 1600A, RATED CURRENT ISD=1.5 TO 8 X IR, II=6 X IN SHORT-CIRCUIT PROTECTION IR= 700-1600A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 1600 UL; TYPE PG (CAT NO. NPX3U160) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD BREAKING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 1600A, RATED CURRENT ISD=1.5 TO 8 X IR, II=6 X IN SHORT-CIRCUIT PROTECTION IR= 700-1600A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 1600 UL; TYPE PG (CAT NO. NPX3D160) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD BREAKING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 1600A, RATED CURRENT ISD=1.25 TO 10 X IR, II=6X IN SHORT-CIRCUIT PROTECTION IR= 700-1600A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 1600 UL; TYPE PG (CAT NO. NPX3E160) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD BREAKING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 1600A, RATED CURRENT ISD=1.25 TO 10 X IR, II=6 X IN SHORT-CIRCUIT PROTECTION IR= 700-1600A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1600 UL; type PG (cat no. NPX3B160) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole, NEMA rating 35kA/480V, (molded case circuit breaker) trip unit TM, LI TA=40?C In=< 1600A, rated current II=7000...12000A short-circuit protection IR=1600A ETU for line protection without connection accessories without auxiliary release
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1600 UL; type PG (cat no. NPX3R160) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole, NEMA rating 35kA/480V, (molded case circuit breaker) trip unit ETU, LI TA=40?C In=1600A, rated current II=1.25 to 6 xIN, short-circuit protection IR=700-1600A overcurrent rel. for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1600 UL; type PG (cat no. NPX3W160) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole, NEMA rating 35kA/480V, (molded case circuit breaker) trip unit ETU, LIG TA=40?C 3 phases/4 lines In=1600A, rated current II=1.25 to 6 xIN, short-circuit protection IR=700-1600A overcurrent rel. for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1600 UL; type PG (cat no. NPX3T160) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole, NEMA rating 35kA/480V, (molded case circuit breaker) trip unit ETU, LSI TA=40?C In=1600A, rated current ISD=1.5 to 8 xIR, II=6 xIN short-circuit protection IR=700-1600A overcurrent rel. for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1600 UL; type PG (cat no. NPX3V160) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole, NEMA rating 35kA/480V, (molded case circuit breaker) trip unit ETU, LSIG TA=40?C 3 phases/4 lines In=1600A, rated current ISD=1.5 to 8 xIR, II=6 xIN short-circuit protection IR=700-1600A overcurrent rel. for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1600 UL type PG (cat no. NPX3A160) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35kA/480V and 25kA/600V (molded case circuit breaker) trip unit LCD ETU, LI/LS/LSI TA=40?C In=1600A, rated current ISD=1.25-10xIR, II=6xIN short-circuit protection IR=700-1600A overcurrent rel. for line protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1600 UL type PG (cat no. NPX3K160) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35kA/480V and 25kA/600V (molded case circuit breaker) trip unit LCD ETU, LSIG-G with alarm TA=40?C 3 phases/4 lines In=1600A, rated current ISD=1.25-10xIR, II=6xIN short-circuit protection IR=700-1600A overcurrent rel. for line protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1600 UL type PG (cat no. NPX3G160) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35kA/480V and 25kA/600V (molded case circuit breaker) trip unit LCD ETU, LSIG TA=40?C 3 phases/4 lines In=1600A, rated current ISD=1.25-10xIR, II=6xIN short-circuit protection IR=700-1600A overcurrent rel. for line protection
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 1600 UL; TYPE PG (CAT NO. NPX3N160) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LI TU= 40 DEGR. CELSIUS IN= 1600A, RATED CURRENT II= 1.25 TO 6 X IN, SHORT-CIRCUIT PROTECTION IR= 700-1600A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES