• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.

Circuit Breaker VL150 UL

Showing 121-140 of 176 Products

3VL2515-1PB30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL150 UL type DG (cat no. NDK3R150) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35KA@480V and 18KA@600/347V (molded case circuit breaker) Electronic Trip Unit ETU, LI TA=40?C In=150A, rated current II=1.25-11 xIN, short-circuit protection Ir=60-150A Electronic Trip Unit for line protection without connection accessories

3VL2515-1PB30-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL150 UL type DG (cat no. NDK3R150) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35KA@480V and 18KA@600/347V (molded case circuit breaker) Electronic Trip Unit ETU, LI TA=40?C In=150A, rated current II=1.25-11 xIN, short-circuit protection Ir=60-150A Electronic Trip Unit for line protection without connection accessories

3VL2515-1PD30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL150 UL type DG (cat no. NDK3W150) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35KA@480V and 18KA@600/347V (molded case circuit breaker) Electronic Trip Unit ETU, LIG TA=40?C 3 phases/4 lines In=150A, rated current II=1.25-11 xIN, short-circuit protection Ir=60-150A Electronic Trip Unit for line protection without connection accessories

3VL2515-1PD30-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL150 UL type DG (cat no. NDK3W150) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35KA@480V and 18KA@600/347V (molded case circuit breaker) Electronic Trip Unit ETU, LIG TA=40?C 3 phases/4 lines In=150A, rated current II=1.25-11 xIN, short-circuit protection Ir=60-150A Electronic Trip Unit for line protection without connection accessories

3VL2515-1PE30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL150 UL type DG (cat no. NDK3T150) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35KA@480V and 18KA@600/347V (molded case circuit breaker) Electronic Trip Unit ETU, LSI TA=40?C In=150A, rated current ISD=1.5-10xIR, II=11xIN short-circuit protection Ir=60-150A Electronic Trip Unit for line protection without connection accessories

3VL2515-1PE30-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL150 UL type DG (cat no. NDK3T150) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35KA@480V and 18KA@600/347V (molded case circuit breaker) Electronic Trip Unit ETU, LSI TA=40?C In=150A, rated current ISD=1.5-10xIR, II=11xIN short-circuit protection Ir=60-150A Electronic Trip Unit for line protection without connection accessories

3VL2515-1PH30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL150 UL type DG (cat no. NDK3V150) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35KA@480V and 18KA@600/347V (molded case circuit breaker) Electronic Trip Unit ETU, LSIG TA=40?C 3 phases/4 lines In=150A, rated current ISD=1.5-10xIR, II=11xIN short-circuit protection Ir=60-150A Electronic Trip Unit for line protection without connection accessories

3VL2515-1PH30-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL150 UL type DG (cat no. NDK3V150) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35KA@480V and 18KA@600/347V (molded case circuit breaker) Electronic Trip Unit ETU, LSIG TA=40?C 3 phases/4 lines In=150A, rated current ISD=1.5-10xIR, II=11xIN short-circuit protection Ir=60-150A Electronic Trip Unit for line protection without connection accessories

3VL2515-1VH30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL150 UL type DG (cat no. NDK3A150) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35KA@480V and 18KA@600/347V (molded case circuit breaker) Electronic Trip Unit LCD ETU, LI/LS/LSI TA=40?C In=150A, rated current ISD=1.25-10xIR, II=11X in short-circuit protection Ir=60-150A Electronic Trip Unit for line protection without connection accessories

3VL2515-1VH30-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL150 UL type DG (cat no. NDK3A150) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35KA@480V and 18KA@600/347V (molded case circuit breaker) Electronic Trip Unit LCD ETU, LI/LS/LSI TA=40?C In=150A, rated current ISD=1.25-10xIR, II=11X in short-circuit protection Ir=60-150A Electronic Trip Unit for line protection without connection accessories

3VL2515-1VJ30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL150 UL type DG (cat no. NDK3K150) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35KA@480V and 18KA@600/347V (molded case circuit breaker) Electronic Trip Unit LCD ETU, LSIG-G with alarm TA=40?C 3 phases/4 lines In=150A, rated current ISD=1.25-10xIR, II=11X in short-circuit protection Ir=60-150A Electronic Trip Unit for line protection without connection accessories

3VL2515-1VJ30-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL150 UL type DG (cat no. NDK3K150) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35KA@480V and 18KA@600/347V (molded case circuit breaker) Electronic Trip Unit LCD ETU, LSIG-G with alarm TA=40?C 3 phases/4 lines In=150A, rated current ISD=1.25-10xIR, II=11X in short-circuit protection Ir=60-150A Electronic Trip Unit for line protection without connection accessories

3VL2515-1VM30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL150 UL type DG (cat no. NDK3G150) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35KA@480V and 18KA@600/347V (molded case circuit breaker) Electronic Trip Unit LCD ETU, LSIG TA=40?C 3 phases/4 lines In=150A, rated current ISD=1.25-10xIR, II=11X in short-circuit protection Ir=60-150A Electronic Trip Unit for line protection without connection accessories

3VL2515-1VM30-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL150 UL type DG (cat no. NDK3G150) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35KA@480V and 18KA@600/347V (molded case circuit breaker) Electronic Trip Unit LCD ETU, LSIG TA=40?C 3 phases/4 lines In=150A, rated current ISD=1.25-10xIR, II=11X in short-circuit protection Ir=60-150A Electronic Trip Unit for line protection without connection accessories

3VL2515-2KE30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL150 UL type DG (cat no. HDR3S150) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole; NEMA rating 65KA@480V and 18KA@600/347V (molded case switch) Electronic Trip Unit magnetic TA=40?C In=150A, rated current II=2500A short-circuit protection non-auto. air circuit breaker without connection accessories

3VL2515-2KJ30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL150 UL type DG (cat no. HDP3L150) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole; NEMA rating 65KA@480V and 18KA@600/347V (motor starter protector) Electronic Trip Unit magnetic TA=40?C In=150A, rated current II=450..900A short-circuit protection starter combination without connection accessories

3VL2515-2KK30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL150 UL type DG (cat no. HDP3M150) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole; NEMA rating 65KA@480V and 18KA@600/347V (motor starter protector) Electronic Trip Unit magnetic TA=40?C In=150A, rated current II=750..1500A short-circuit protection starter combination without connection accessories

3VL2515-2KL30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL150 UL type DG (cat no. HDP3H150) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole; NEMA rating 65KA@480V and 18KA@600/347V (motor starter protector) Electronic Trip Unit magnetic TA=40?C In=150A, rated current II=1250..2500A short-circuit protection starter combination without connection accessories

3VL2515-2KN30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL150 UL type DG (cat no. HDK3B150) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole; NEMA rating 65KA@480V and 18KA@600/347V (molded case circuit breaker) Electronic Trip Unit TM, LI TA=40?C In=150A, rated current II=800...1600A short-circuit protection Ir=150A Electronic Trip Unit for line protection without connection accessories

3VL2515-2KN31-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL150 UL type DG (cat no. HDK3B150K) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole; NEMA rating 65KA@480V and 18KA@600/347V (molded case circuit breaker) Electronic Trip Unit TM, LI TA=40?C In=150A, rated current II=800...1600A short-circuit protection Ir=150A Electronic Trip Unit for line protection with terminals feeder-side (line)