3VL7710-2NH46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU22, LSIG In=1000A, rated current IR=400...1000A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection N protected ETU communication-capable

3VL7710-2NH46-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU22, LSIG In=1000A, rated current IR=400...1000A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection N protected without auxiliary release ETU communication-capable

3VL7710-2NN46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU12, LIG In=1000A, rated current IR=400...1000A, overload protection, II=1.25 to 11xIN, short-circuit protection N protected ETU communication-capable

3VL7710-2NN46-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU12, LIG In=1000A, rated current IR=400...1000A, overload protection, II=1.25 to 11xIN, short-circuit protection N protected without auxiliary release ETU communication-capable

3VL7710-2TA46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU10, LIN In=1000A, rated current IR=400...1000A, overload protection, II=1.25 to 11xIN, short-circuit protection N protected

3VL7710-2TB46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU10, LI In=1000A, rated current IR=400...1000A, overload protection, II=1.25 to 11xIN, short-circuit protection

3VL7710-2TE46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU20, LSI In=1000A, rated current IR=400...1000A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection N unprotected

3VL7710-2TF46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU20, LSI In=1000A, rated current IR=400...1000A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection N protected

3VL7710-2TH46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU22, LSIG In=1000A, rated current IR=400...1000A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection N protected

3VL7710-2TN46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU12, LIG In=1000A, rated current IR=400...1000A, overload protection, II=1.25 to 11xIN, short-circuit protection N protected

3VL7710-2UJ46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit LCD ETU40, LI/LS/LSI In=1000A, rated current IR=400...1000A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection N protected

3VL7710-2UN46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit LCD ETU42, LSIG In=1000A, rated current IR=400...1000A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection N protected with ground-fault protection

3VL7712-2AA46-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H w/o Electronic Trip Unit high breaking capacity Icu=70kA/415V AC, 4-pole In=< 1250A, rated current without auxiliary release with screw terminal connections for switching unit and ETU

3VL7712-2BA46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 1250H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU10, LI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT N PROTECTED

3VL7712-2BB46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 1250H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU10, LI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT N NOT PROTECTED

3VL7712-2BC46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 1250H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU12, LIG IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT N NOT PROTECTED

3VL7712-2BD46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 1250H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU12, LIG IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT N PROTECTED

3VL7712-2BE46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 1250H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU20, LSI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT N NOT PROTECTED

3VL7712-2BF46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 1250H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU20, LSI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT N PROTECTED