[Add to Enquire List] [Remove from Inquiry List]CIRCUIT BREAKER 3VA2 IEC CIRCUIT BREAKER 3VA2 IEC FRAME 630 FRAME 630 BREAKING CAPACITY CLASS L BREAKING CAPACITY CLASS L ICU=150KA @ 415 V ICU=150KA @ 415 V 3-POLE, LINE PROTECTION 3-POLE, LINE PROTECTION ETU320, LI, IN=630A ETU320, LI, IN=630A OVERLOAD PROTECTION OVERLOAD PROTECTION IR=252A ...630A IR=252A ...630A SHORT CIRCUIT PROTECTION SHORT CIRCUIT PROTECTION II=10 X IN II=10 X IN - - - - - - - - BUSBAR CONNECTION BUSBAR CONNECTION
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT BREAKER 3VA2 IEC FRAME 630 BREAKING CAPACITY CLASS V ICU=150KA @ 415 V 3-POLE, LINE PROTECTION ETU330, LIG, IN=630A OVERLOAD PROTECTION IR=252A ...630A SHORT CIRCUIT PROTECTION II=1,5 X IN GROUND-FAULT-PROTECTION IG=0,2... 1 X IN, TG=100/300MS BUSBAR CONNECTION
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT BREAKER 3VA2 IEC FRAME 630 BREAKING CAPACITY CLASS V ICU=150KA @ 415 V 4-POLE, LINE PROTECTION ETU330, LIG, IN=630A OVERLOAD PROTECTION IR=252A ...630A SHORT CIRCUIT PROTECTION II=1,5 X IN NEUTRAL PROTECTION ADJUSTABLE(OFF,50%,100%) GROUND-FAULT-PROTECTION IG=0,2... 1 X IN, TG=100/300MS BUSBAR CONNECTION
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT BREAKER 3VA2 IEC FRAME 630 BREAKING CAPACITY CLASS V ICU=150KA @ 415 V 3-POLE, LINE PROTECTION ETU350, LSI, IN=630A OVERLOAD PROTECTION IR=252A ...630A SHORT CIRCUIT PROTECTION ISD=1,5... 10 X IR, II=10 X IN BUSBAR CONNECTION
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT BREAKER 3VA2 IEC FRAME 630 BREAKING CAPACITY CLASS V ICU=150KA @ 415 V 4-POLE, LINE PROTECTION ETU350, LSI, IN=630A OVERLOAD PROTECTION IR=252A ...630A SHORT CIRCUIT PROTECTION ISD=1,5... 10 X IR, II=10 X IN NEUTRAL PROTECTION ADJUSTABLE(OFF,50%,100%) BUSBAR CONNECTION
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT BREAKER 3VA2 IEC FRAME 630 BREAKING CAPACITY CLASS V ICU=150KA @ 415 V 3-POLE, LINE PROTECTION ETU550, LSI, IN=630A OVERLOAD PROTECTION IR=252A ...630A SHORT CIRCUIT PROTECTION ISD=0,6... 10 X IN, II=1,5 X IN NEUTRAL PROTECTION OPTIONAL WITH EXT. CT BUSBAR CONNECTION
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT BREAKER 3VA2 IEC FRAME 630 BREAKING CAPACITY CLASS V ICU=150KA @ 415 V 4-POLE, LINE PROTECTION ETU550, LSI, IN=630A OVERLOAD PROTECTION IR=252A ...630A SHORT CIRCUIT PROTECTION ISD=0,6... 10 X IN, II=1,5 X IN NEUTRAL PROTECTION ADJUSTABLE(OFF,50%,100%) BUSBAR CONNECTION
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT BREAKER 3VA2 IEC FRAME 630 BREAKING CAPACITY CLASS V ICU=150KA @ 415 V 3-POLE, LINE PROTECTION ETU560, LSIG, IN=630A OVERLOAD PROTECTION IR=252A ...630A SHORT CIRCUIT PROTECTION ISD=0,6... 10 X IN, II=1,5 X IN NEUTRAL PROTECTION OPTIONAL WITH EXT. CT GROUND-FAULT, SWITCHABLE IG=0,2... 1 X IN, TG=50-800MS BUSBAR CONNECTION
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT BREAKER 3VA2 IEC FRAME 630 BREAKING CAPACITY CLASS V ICU=150KA @ 415 V 4-POLE, LINE PROTECTION ETU560, LSIG, IN=630A OVERLOAD PROTECTION IR=252A ...630A SHORT CIRCUIT PROTECTION ISD=0,6... 10 X IN, II=1,5 X IN NEUTRAL PROTECTION ADJUSTABLE(OFF,50%,100%) GROUND-FAULT, SWITCHABLE IG=0,2... 1 X IN, TG=50-800MS BUSBAR CONNECTION
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT BREAKER 3VA2 IEC FRAME 630 BREAKING CAPACITY CLASS V ICU=150KA @ 415 V 3-POLE, LINE PROTECTION ETU850, LSI, IN=630A OVERLOAD PROTECTION IR=252A ...630A SHORT CIRCUIT PROTECTION ISD=0,6... 10 X IN, II=1,5 X IN NEUTRAL PROTECTION OPTIONAL WITH EXT. CT BUSBAR CONNECTION
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT BREAKER 3VA2 IEC FRAME 630 BREAKING CAPACITY CLASS V ICU=150KA @ 415 V 4-POLE, LINE PROTECTION ETU850, LSI, IN=630A OVERLOAD PROTECTION IR=252A ...630A SHORT CIRCUIT PROTECTION ISD=0,6... 10 X IN, II=1,5 X IN NEUTRAL PROTECTION ADJUSTABLE(OFF,50%,100%) BUSBAR CONNECTION
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT BREAKER 3VA2 IEC FRAME 630 BREAKING CAPACITY CLASS V ICU=150KA @ 415 V 3-POLE, LINE PROTECTION ETU860, LSIG, IN=630A OVERLOAD PROTECTION IR=252A ...630A SHORT CIRCUIT PROTECTION ISD=0,6... 10 X IN, II=1,5 X IN NEUTRAL PROTECTION OPTIONAL WITH EXT. CT GROUND-FAULT, SWITCHABLE IG=0,2... 1 X IN, TG=50-800MS BUSBAR CONNECTION
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT BREAKER 3VA2 IEC FRAME 630 BREAKING CAPACITY CLASS V ICU=150KA @ 415 V 4-POLE, LINE PROTECTION ETU860, LSIG, IN=630A OVERLOAD PROTECTION IR=252A ...630A SHORT CIRCUIT PROTECTION ISD=0,6... 10 X IN, II=1,5 X IN NEUTRAL PROTECTION ADJUSTABLE(OFF,50%,100%) GROUND-FAULT, SWITCHABLE IG=0,2... 1 X IN, TG=50-800MS BUSBAR CONNECTION