A1D00119707

A1D00119707

Manufacturer: SIEMENS

Price: On Request

With the Option Bypass function SIPLACE X-series the placement machine can be used as bypass, e.g. in case of machine downtime. This increases the line availability . Retrofitable in all X Series machines (incl X4i).


Similar items in same category:
A1D00119696 A1D00119696 With the Option Retrofit Vacuumpump SIPLACE HF a SIPLACE HF can be conne cted to an external Vacuumpump. This reduces the air consumption C&P Hea d + Twin Head to 250NL/min and C&P Head + C&P Head to 200NL/min. To guar antee the specification of SIPLACE HF the vacuumpump must fulfill the sp ecification of Siemens. More details from the respective Sales or Servic e representative.
A1D00119696-01 A1D00119696-01 WITH THE OPTION RETROFIT VACUUM PUMP SIPLACE HF A SIPLACE HF/X2 CAN BECONNECTED TO AN EXTERNAL VACUUMPUMP. THIS REDUCES THE A IR CONSUMPTION C&P HEAD + TWIN HEAD TO 250NL/MIN AND C&P HEAD + C&P HEAD TO 200NL/MIN.TO GUAR ANTEE THE SPECIFICATION OF SIPL ACE HF/X2 THE VACUUMPUMP MUSTFU LFILL THE SPECIFICATION OF SIEM ENS. MORE DETAILS FROM THE RESP ECTIVESALES OR SERVICE REPRESEN TATIVE.
A1D00119697 A1D00119697 With the Option Retrofit Vacuumpump SIPLACE HF/3 a SIPLACE HF/3 can be connected to an external Vacuumpump. This reduces the air consumption 2xC&P Head + Twin Head to 350NL/min and 3xC&P Head to 300NL/min. To guarantee the specification of SIPLACE HF/3 the vacuumpump must fulfill the specification of Siemens. More details from the respective Sales or Service representative.
A1D00119700 A1D00119700 2 Gantry SMD placement station SIPLACE X2 with maximum benchmark placement rate of 49.000 cph. One of the following configurations must be selected : - 77119700 SIPLACE X2 with software 60x - 77119701 SIPLACE X2-A with software 70x equipped with 2 C+P heads (20 or CPP) - 77119702 SIPLACE X2-B with software 70x equipped with 1 C+P heads (20 or CPP) and 1 Twin Head - 77119703 SIPLACE X2-C with software 70x equipped with 2 Twin Heads For detailed technical information please refer to the current Scope of Delivery and the corresponding specifications: - "SIPLACE X-Series Specification 07/2008 Edition" or later for software 60x - "SIPLACE X-Series powered by MultiStar Specification 03/2009 Edition" or later for software 702. The machine can be equipped with a single lane transport (item no: 119625) or alternatively with a flexible dual lane transport (item no: 119627). Information regarding the PCB size can be found under the respective item no. The transport must be configured during order. For software 702, please note that only 20, CPP and Twin Head, X-changeover table and X-feeders is supported. For software 60x, please note that CPP head is not supported. A moveable changeover table can be used at all 4 setup areas of one placement system. The table enables fast setup changes. Each setup area should be equipped with a changeover table and the respective interface when ordering a machine. The use of X-feeder changeover table (item no: 119722) allows the use of intelligent X-Feeders. In addition to that, interface X-changeover table (item no: 119723) for each setup area has to be ordered. Alternatively, for software 60x only, the changeover table of SIPLACE HF (item no: 119622) can be used. On these tables only SIPLACE S-feeders can be used. As the energy und data interface is different between the two feeder types the respective interface should be ordered with the machine. In addition to that, interface HF-changeover table (item no: 119724), for each setup area has to be ordered. The Matrix Tray Changer 2 (item no.116438) for tray components is available as an option for setup area 2 and 4. Tape disposal is made easy with the integrated automatic tape cutters. Placement station heights configuration: 830mm/900mm/930mm/950mm. The Windows XP based station computer with Touch-Screen monitor is the operators interface to the machine. Four days of basic instruction und pre acceptance at supplier site per line are included in the placement station order.
A1D00119710 A1D00119710 The optional Head Interface cover X-Series is only possible with a cable trailing which supports the vacuum machine (Machine serial number B-079 and higher).These option is independently from the head configuration and must be ordered for each gantry separately. A retrofit of this Option at machines with serial number B-079 at customer side is possible within 15 minutes per gantry.
A1D00119715 A1D00119715 Nozzle Changer for 20-Segment Collect and Place Head SIPLACE X-Series. For each Collect and Place Head one Nozzle Changer is required. The option contains 6 magazines each 12 nozzles. The nozzle reject device is part of the standard configuration with 20 Nozzle C+P head. This item number is for initial equipment. If an additional nozzle changers are required the item no. 119716 (nozzle changer add. X-Serie/C+P20) must be ordered.
A1D00119716 A1D00119716 Additional Nozzle Changer for 20-Segment Collect and Place Head SIPLACE X-Series. It is possible to place maximal two nozzle changers for each Collect and Place Head. The option contain 6 magazines for 12 nozzles per magazine include material. For initial equipment the nozzle changer SIPLACE X-Series/C+P20 (Item No.: 119715) must be ordered.
A1D00119717 A1D00119717 Second nozzle changer for TwinHead at SIPLACE HF-Series, X-Series and D3 from SW 602, Siplace Pro 3.1. Machine can be equipped with max. two nozzle changers per placement area (the first nozzle changer belongs to the standard configuration of HF,HF/3,X-Series,D3). The second nozzle changer can be mounted at setup location 2 and 4. These additional nozzle changer is not possible together with MTC2. The nozzle changer can only provided with up to 12 nozzle magazines. Two different magazine types are available: standard magazines (03005191-02) and magazines for special nozzles / grippers (03001807-01). The option already contains three standard magazines and one special magazine. Preconditions:Line software Siplace Pro 2.1 or higher, Station software 505.03 or higher.