• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.
A1D00119463

A1D00119463

Manufacturer: SIEMENS

Price: On Request

Fixed conveyor rail left side to transport two PCBs. Synchronous or asyn chronous transport mode. Item has to be ordered with the placement stati on. With this new transport the PCB is clamped to top side, that means t he placement level is always on the same height, independent from PCB-Th ickness. The new transport offers short PCB change time and the possibil ity to change easily the fixed rail Right - Left. PCB-dimensions: L x W, Standard: 50mm x 50mm to 368mm x 216mm. Extended dimensions with the Lo ng Board Option: 50mm x 110mm to 610mm x 216mm (242mm width on request).


Similar items in same category:
A1D00119455-01 A1D00119455-01 WIDE BOARD OPTION OFFERS THE PO SSIBILITY TO PROCESS WIDE PCBS ON ANHS60/D4. THEREFORE IT IS N ECESSARY TO DO SOME MODIFICATIO NS AT THE LIMITSWITCHES OF Y-AX IS AND TO MOVE THE POSITION OF THE FIXED RAIL OF THECONVEYOR. BY USE OF THIS OPTION, BOARDS W ITH A WIDTH UP TO 508MM CAN BEH ANDLED BY AN HS60/D4 WITH SINGL E CONVEYOR. FOR DUAL CONVEYOR T HEMAXIMUM PCB WIDTH IS 242MM IN DUAL CONVEYOR MODE AND 380MM I N SINGLECONVEYOR MODE. ATTENTIO N: IT IS NOT POSSIBLE TO USE SY NCHRONOUS DUALCONVEYOR IN COMBI NATION WITH WIDE BOARD OPTION. PRECONDITIONS: LINE SOFTWARE SI PLACE PRO 2.1 OR HIGHER, STATIO N SOFTWARE505.03 OR HIGHER.
A1D00119460 A1D00119460 Fixed conveyor rail right side. To transport two PCBs. Synchronous or as ynchronous transport mode. Item has to be ordered with the placement sta tion. With this new transport the PCB is clamped to top side, that means the placement level is always on the same height, independent from PCB- Thickness. The new transport offers short PCB change time and the possib ility to change easily the fixed rail Right - Left. PCB-dimensions: L x W, Standard: 50mm x 50mm to 368mm x 460mm, Extended dimensions with the Long Board Option: 50mm x 110mm to 610mm x 460mm (508mm extra width on r equest).
A1D00119461 A1D00119461 Fixed conveyor rail left side.Item has to be ordered with the placement station. With this new transport the PCB is clamped to top side, that me ans the placement level is always on the same height, independent from P CB-Thickness. The new transport offers short PCB change time and the pos sibility to change easily the fixed rail Right <-> Left. PCB-dimensions: L x W, Standard: 50mm x 50mm to 368mm x 460mm. Extended dimensions with the Long Board Option: 50mm x 110mm to 610mm x 460mm (508mm extra width on request).
A1D00119462 A1D00119462 Fixed conveyor rail right side to transport two PCBs. Synchronous or asy nchronous transport mode. Item has to be ordered with the placement stat ion. With this new transport the PCB is clamped to top side, that means the placement level is always on the same height, independent from PCB-T hickness. The new transport offers short PCB change time and the possibi lity to change easily the fixed rail Right - Left. PCB-dimensions: L x W , Standard: 50mm x 50mm to 368mm x 216mm, Extended dimensions with the L ong Board Option: 50mm x 110mm to 610mm x 216mm (242mm extra width on re quest).
A1D00119475 A1D00119475 PCB vision module Multicolor for placement stations HS60 and HS50 with i ntegrated oblique IR-and blue illumination.Compact unit.For best recogni tion of bare PCB fiducials on bright PCB basis material (ceramic substra tes, CEM etc.), Flex Boards and fluctuations of PCB surfaces. Comfortabl e handling and adjustment. Item number only for new machines, for retrof it part number 358031.
A1D00119600 A1D00119600 SMD placement station for End-of-Line/High-End components with a maximum placement rate of 17,000 cph (in accordance with Scope of Service and D elivery). The placement station provides a feeder capacity of maximum 18 0 x 8mm tapes. The placement station is equipped with a 12-Segment Colle ct and Place Head respectively a 6-Segment Collect and Place Head or a T win Head. The following head configurations are included as standard sco pe of delivery: Gantry 1: Twin Head (item no. 119620) Gantry 3: Twin Hea d (item no. 119620). By ordering an HF placement station an additional d efinition of the placement head configuration in placement area 1 and 2 (ex SW 505)is required: 12-Segment Collect and Place Head (item no. 1196 16), 6-Segment Collect and Place Head (item no. 119615), Twin Head (ite m no. 119620). In placement area 2 only the Twin Head (pre SW 505)will b e available. Depending on the head configuration the placement station i s capable to handle a component range starting with 0.6mm x 0.3mm (0201) or alternatively 1.5mm x 0.8mm (0603) up to 50mm x 50mm (dual nozzle op eration) or 125mm x 10mm (single nozzle operation). Max. component heigh t is 25mm. Larger components are possible (on request). For 0201 placeme nt we recommend the 0201 Package Phase 2 (item no. 118020). Regarding PC B conveyor please have a look at: Item no. 119625 modular single conveyo r II 2380mm or Item no. 119627 modular dual conveyor II 2380mm. At all locations the changeover table is configured as a standard and enables a fast setup and changeovers. The Matrix Tray Changer 2 (item no.116438) is available as an option for locations 2 and 4. An easy tape disposal is provided with the integrated automatic tape cutters. Standard height placement station is 830mm. The Windows based station computer with touc h screen monitor is the operators interface to the placement system. Fou r days of basic instructions and pre acceptance at suppliers site per li ne are included in the placement station order.
A1D00119605 A1D00119605 Power Supply Conversion Instructions 110V for SIPLACE HF/X-Series/D1/D2/D3. Delivery and conversion are part from the station and free of charge. Attention: If retrofitted at a costumer a voltage savety check (DIN EN 60 204) is necessary. For assistance please ask SIPLACE SMT Service.
A1D00119605S02 A1D00119605S02 Power Supply Conversion Instructions 110V for SIPLACE HF/X-Series. Attention: If retrofitted at a costumer a voltage savety check (DIN EN 60 204) is necessary. For assistance please ask SIPLACE SMT Service.