8BK3020-1QA10-0JB5

8BK3020-1QA10-0JB5

Manufacturer: SIEMENS

Price: On Request

WITHDRAWABLE VACUUM CONTACTOR SECT. WITH CONTACT ARMS AND MOUNTING OF 3TL6 CONTACTOR FOR WITHDRAWABLE PANEL 7.2KV , 400A . . WITH 1 H.V.HRC FUSE HOLDER TO DIN 43625 FOR EACH CONDUCTOR WITH MECHANICAL ON LATCHING OF THE VACUUM CONTACTOR MECHANICALLY INTERLOCKED AGAINST EARTHING SWITCH CONTACTOR PERMANENTLY FORCED WITH AUXILIARY SWITCH F.WITHDRAW. SECT.POS.INDICATION 2NO EACH FOR CONNECTED AND DISCONNECTED POSITION W. FITTING OF SURGE LIMITERS


Similar items in same category:
8BK3020-1HB00-5BC1 8BK3020-1HB00-5BC1 EARTHING SWITCH AT CONNECTION OF WITHDRAWABLE PANEL 7.2KV RATED SHORT-TIME CURRENT 8KA/1S WITH MAKING CAPACITY MAX. 20KA MANUAL OPERATING MECHANISM MECHANICALLY INTERLOCKED AGAINST DRAW-OUT SECTION W.PADLOCKING FACILITY WITH AUXILIARY SWITCH 1NO+1NC F.EARTH.SWITCH STATE INDICATION
8BK3020-1QA1.-.... 8BK3020-1QA1.-.... WITHDRAWABLE VACUUM CONTACTOR SECT. WITH CONTACT ARMS AND MOUNTING OF 3TL6 CONTACTOR FOR WITHDRAWABLE PANEL 7.2KV , 400A
8BK3020-1QA10-0DB5 8BK3020-1QA10-0DB5 WITHDRAWABLE VACUUM CONTACTOR SECT. WITH CONTACT ARMS AND MOUNTING OF 3TL6 CONTACTOR FOR WITHDRAWABLE PANEL 7.2KV , 400A . . WITH 2 H.V.HRC FUSE HOLDERS TO DIN 43625 FOR EACH CONDUCTOR MECHANICALLY INTERLOCKED AGAINST EARTHING SWITCH CONTACTOR PERMANENTLY FORCED WITH AUXILIARY SWITCH F.WITHDRAW. SECT.POS.INDICATION 2NO EACH FOR CONNECTED AND DISCONNECTED POSITION W. FITTING OF SURGE LIMITERS
8BK3020-1QA10-0JB2 8BK3020-1QA10-0JB2 WITHDRAWABLE VACUUM CONTACTOR SECT. WITH CONTACT ARMS AND MOUNTING OF 3TL6 CONTACTOR FOR WITHDRAWABLE PANEL 7.2KV , 400A . . WITH 1 H.V.HRC FUSE HOLDER TO DIN 43625 FOR EACH CONDUCTOR WITH MECHANICAL ON LATCHING OF THE VACUUM CONTACTOR MECHANICALLY INTERLOCKED AGAINST EARTHING SWITCH CONTACTOR PERMANENTLY FORCED WITH AUXILIARY SWITCH F.WITHDRAW. SECT.POS.INDICATION 2 NO EACH FOR CONNECTED AND DISCONNECTED POSITION
8BK3020-1QA10-0KB2 8BK3020-1QA10-0KB2 WITHDRAWABLE VACUUM CONTACTOR SECT. WITH CONTACT ARMS AND MOUNTING OF 3TL6 CONTACTOR FOR WITHDRAWABLE PANEL 7.2KV , 400A . . WITH 2 H.V.HRC FUSE HOLDERS TO DIN 43625 FOR EACH CONDUCTOR WITH MECHANICAL ON LATCHING OF THE VACUUM CONTACTOR MECHANICALLY INTERLOCKED AGAINST EARTHING SWITCH CONTACTOR PERMANENTLY FORCED WITH AUXILIARY SWITCH F.WITHDRAW. SECT.POS.INDICATION 2 NO EACH FOR CONNECTED AND DISCONNECTED POSITION
8BK3020-1QA11-0CB2 8BK3020-1QA11-0CB2 WITHDRAWABLE VACUUM CONTACTOR SECT. WITH CONTACT ARMS AND MOUNTING OF 3TL6 CONTACTOR FOR WITHDRAWABLE PANEL 7.2KV , 400A LV PLUG WITHOUT ALARM FACILITY: LV PLUG DISCONNECTED . WITH 1 H.V.HRC FUSE HOLDER TO DIN 43625 FOR EACH CONDUCTOR MECHANICALLY INTERLOCKED AGAINST EARTHING SWITCH CONTACTOR PERMANENTLY FORCED WITH AUXILIARY SWITCH F.WITHDRAW. SECT.POS.INDICATION 2 NO EACH FOR CONNECTED AND DISCONNECTED POSITION
8BK3020-1QA11-0CB5 8BK3020-1QA11-0CB5 WITHDRAWABLE VACUUM CONTACTOR SECT. WITH CONTACT ARMS AND MOUNTING OF 3TL6 CONTACTOR FOR WITHDRAWABLE PANEL 7.2KV , 400A LV PLUG WITHOUT ALARM FACILITY: LV PLUG DISCONNECTED . WITH 1 H.V.HRC FUSE HOLDER TO DIN 43625 FOR EACH CONDUCTOR MECHANICALLY INTERLOCKED AGAINST EARTHING SWITCH CONTACTOR PERMANENTLY FORCED WITH AUXILIARY SWITCH F.WITHDRAW. SECT.POS.INDICATION 2NO EACH FOR CONNECTED AND DISCONNECTED POSITION W. FITTING OF SURGE LIMITERS
8BK3020-1QA11-0JB5 8BK3020-1QA11-0JB5 WITHDRAWABLE VACUUM CONTACTOR SECT. WITH CONTACT ARMS AND MOUNTING OF 3TL6 CONTACTOR FOR WITHDRAWABLE PANEL 7.2KV , 400A LV PLUG WITHOUT ALARM FACILITY: LV PLUG DISCONNECTED . WITH 1 H.V.HRC FUSE HOLDER TO DIN 43625 FOR EACH CONDUCTOR WITH MECHANICAL ON LATCHING OF THE VACUUM CONTACTOR MECHANICALLY INTERLOCKED AGAINST EARTHING SWITCH CONTACTOR PERMANENTLY FORCED WITH AUXILIARY SWITCH F.WITHDRAW. SECT.POS.INDICATION 2NO EACH FOR CONNECTED AND DISCONNECTED POSITION W. FITTING OF SURGE LIMITERS