• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.
8BK2040-1AG04-1JC1

8BK2040-1AG04-1JC1

Manufacturer: SIEMENS

Price: On Request

FRAME FOR WITHDRAWABLE PANEL WITH DOOR, COMPARTMENTALIZATION PENETRATION-TYPE BUSHINGS, SHUTTER DRIVE AND RAILS TO SUPPORT WITHDRAWABLE SECTION 12KV 25KA MAX. 3SEC. W.CABLE CONNECTION AT THE FRONT PRESSURE RELIEF OF THE TERMINAT. COMPARTMENT UPWARDS FOR WALL MOUNTING OR FREE-STANDING ARRANGEMENT WITH REAR DUCT W. COMPARTMENTALIZATION OF THE BUSBAR COMPARTMENT AND CABLE TERMINATION COMPARTMENT FOR 3AH1 VACUUM CIRCUIT-BREAKER RESIST. TO INTERNAL ARC FAULTS: ARCING TIME 1S CRITERIA 1 TO 3 AND 6 ACCORDING TO VDE 0670


Similar items in same category:
8BK2040-1AF02-1BC1 8BK2040-1AF02-1BC1 FRAME FOR WITHDRAWABLE PANEL WITH DOOR, COMPARTMENTALIZATION PENETRATION-TYPE BUSHINGS, SHUTTER DRIVE AND RAILS TO SUPPORT WITHDRAWABLE SECTION 12KV 20KA MAX. 3SEC. W.CABLE CONNECTION AT THE FRONT PRESSURE RELIEF OF THE TERMINAT. COMPARTMENT TO REAR FOR WALL MOUNTING W. COMPARTMENTALIZATION OF THE BUSBAR COMPARTMENT AND CABLE TERMINATION COMPARTMENT F. 3AH5 VACUUMCIRCUIT-BREAKER RESIST. TO INTERNAL ARC FAULTS: ARCING TIME 1S CRITERIA 1 TO 3 AND 6 ACCORDING TO VDE 0670, PART 6/IEC 298 SHORT-CIRCUIT CURRENT 16-40KA
8BK2040-1AG0.-.... 8BK2040-1AG0.-.... FRAME FOR WITHDRAWABLE PANEL WITH DOOR, COMPARTMENTALIZATION PENETRATION-TYPE BUSHINGS, SHUTTER DRIVE AND RAILS TO SUPPORT WITHDRAWABLE SECTION 12KV 25KA MAX. 3SEC.
8BK2040-1AG02-1JC1 8BK2040-1AG02-1JC1 FRAME FOR WITHDRAWABLE PANEL WITH DOOR, COMPARTMENTALIZATION PENETRATION-TYPE BUSHINGS, SHUTTER DRIVE AND RAILS TO SUPPORT WITHDRAWABLE SECTION 12KV 25KA MAX. 3SEC. W.CABLE CONNECTION AT THE FRONT PRESSURE RELIEF OF THE TERMINAT. COMPARTMENT TO REAR FOR WALL MOUNTING W. COMPARTMENTALIZATION OF THE BUSBAR COMPARTMENT AND CABLE TERMINATION COMPARTMENT FOR 3AH1 VACUUM CIRCUIT-BREAKER RESIST. TO INTERNAL ARC FAULTS: ARCING TIME 1S CRITERIA 1 TO 3 AND 6 ACCORDING TO VDE 0670, PART 6/IEC 298 SHORT-CIRCUIT CURRENT 16-40KA
8BK2040-1AG04-1FC1 8BK2040-1AG04-1FC1 FRAME FOR WITHDRAWABLE PANEL WITH DOOR, COMPARTMENTALIZATION PENETRATION-TYPE BUSHINGS, SHUTTER DRIVE AND RAILS TO SUPPORT WITHDRAWABLE SECTION 12KV 25KA MAX. 3SEC. W.CABLE CONNECTION AT THE FRONT PRESSURE RELIEF OF THE TERMINAT. COMPARTMENT UPWARDS FOR WALL MOUNTING OR FREE-STANDING ARRANGEMENT WITH REAR DUCT W. COMPARTMENTALIZATION OF THE BUSBAR COMPARTMENT AND CABLE TERMINATION COMPARTMENT FOR DISCONNECTOR-LINK PANEL RESIST. TO INTERNAL ARC FAULTS: ARCING TIME 1S CRITERIA 1 TO 3 AND 6 ACCORDING TO VDE 0670
8BK2040-1AH0.-.... 8BK2040-1AH0.-.... FRAME FOR WITHDRAWABLE PANEL WITH DOOR, COMPARTMENTALIZATION PENETRATION-TYPE BUSHINGS, SHUTTER DRIVE AND RAILS TO SUPPORT WITHDRAWABLE SECTION 12KV 31.5KA MAX. 3SEC.
8BK2040-1AH04-1JC1 8BK2040-1AH04-1JC1 FRAME FOR WITHDRAWABLE PANEL WITH DOOR, COMPARTMENTALIZATION PENETRATION-TYPE BUSHINGS, SHUTTER DRIVE AND RAILS TO SUPPORT WITHDRAWABLE SECTION 12KV 31.5KA MAX. 3SEC. W.CABLE CONNECTION AT THE FRONT PRESSURE RELIEF OF THE TERMINAT. COMPARTMENT UPWARDS FOR WALL MOUNTING OR FREE-STANDING ARRANGEMENT WITH REAR DUCT W. COMPARTMENTALIZATION OF THE BUSBAR COMPARTMENT AND CABLE TERMINATION COMPARTMENT FOR 3AH1 VACUUM CIRCUIT-BREAKER RESIST. TO INTERNAL ARC FAULTS: ARCING TIME 1S CRITERIA 1 TO 3 AND 6 ACCORDING TO VDE 0670
8BK2040-1AJ0.-.... 8BK2040-1AJ0.-.... FRAME FOR WITHDRAWABLE PANEL WITH DOOR, COMPARTMENTALIZATION PENETRATION-TYPE BUSHINGS, SHUTTER DRIVE AND RAILS TO SUPPORT WITHDRAWABLE SECTION 12KV 40KA 1SEC.
8BK2040-1AJ01-1AC0 8BK2040-1AJ01-1AC0 FRAME FOR WITHDRAWABLE PANEL WITH DOOR, COMPARTMENTALIZATION PENETRATION-TYPE BUSHINGS, SHUTTER DRIVE AND RAILS TO SUPPORT WITHDRAWABLE SECTION 12KV 40KA 1SEC. W.CABLE CONNECTION AT THE FRONT PRESSURE RELIEF OF THE TERMINAT. COMPARTMENT DOWNWARDS FOR WALL MOUNTING W. COMPARTMENTALIZATION OF THE BUSBAR COMPARTMENT AND CABLE TERMINATION COMPARTMENT F.3AH3 VACUUMCIRCUIT-BREAKER UPTO 40KA/50KA RESIST. TO INTERNAL ARC FAULTS: ARCING TIME 1S CRITERIA 1 TO 3 AND 6 ACCORDING TO VDE 0670, PART 6/IEC 298