7SR2424-2.A12-0AA0
Manufacturer: SIEMENS
Price: On Request
DUOBIAS-M TRANSFORMER DIFFERENTIAL RELAY (2 WINDING) E12 CASE, 6CT, 2EF/REF CT, 1VT, 39 BINARY INP./ 14 BINARY OUTP. 32 LEDS MEASURING INPUT: 1/5 A 63.5/ 110V, 50/60HZ REGION WORLD, LANGUAGE: ENGLISH USB FRONT PORT, RS485 REAR PORT IEC 60870-5-103, MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) PROTECTION FUNCTION: STANDARD VERSION
Similar items in same category:
7SR2423-2NA87-0CA0 | Transformer differential protection (Duobias- M) E10 enclosure, 6 curr. trans., 2 ES/EDS curr. trans., 1 volt. trans. 19 BI / 14 BO, 24 LEDs Measuring inputs: 1/5A, 40 to 160V, 50/60Hz Auxiliary voltage 24 - 250V DC / 100- 230V AC Threshold binary input: 88V DC USB interface at front, RS485 interface at rear, + optical Ethernet Duplex Protocol: IEC 60870-5-103 and Modbus RTU and DNP 3.0 (adjustable) and IEC 61850 Protective function: Standard version + Option C | |
7SR2424-2.A11-0AA0 | DUOBIAS-M TRANSFORMER DIFFERENTIAL RELAY (2 WINDING) E12 CASE, 6CT, 2EF/REF CT, 1VT, 39 BINARY INP./ 14 BINARY OUTP. 32 LEDS MEASURING INPUT: 1/5 A 63.5/ 110V, 50/60HZ REGION WORLD, LANGUAGE: ENGLISH USB FRONT PORT, RS485 REAR PORT IEC 60870-5-103 AND MODBUS RTU (USER SELECTABLE SETTING) PROTECTION FUNCTION: STANDARD VERSION | |
7SR2424-2.A11-0BA0 | DUOBIAS-M TRANSFORMER DIFFERENTIAL RELAY (2 WINDING) E12 CASE, 6CT, 2EF/REF CT, 1VT, 39 BINARY INP./ 14 BINARY OUTP. 32 LEDS MEASURING INPUT: 1/5 A 63.5/ 110V, 50/60HZ REGION WORLD, LANGUAGE: ENGLISH USB FRONT PORT, RS485 REAR PORT IEC 60870-5-103 AND MODBUS RTU (USER SELECTABLE SETTING) PROTECTION FUNCTION: STANDARD VERSION + UNDERCURRENT (37) NEGATIVE PHASE SEQUENCY O/C THERMAL OVERLOAD (49) INSTANTANEOUS PHASE FAULT O/C INSTANTANEOUS EARTH FAULT TIME DELAYED PHASE FAULT O/C | |
7SR2424-2.A11-0CA0 | DUOBIAS-M TRANSFORMER DIFFERENTIAL RELAY (2 WINDING) E12 CASE, 6CT, 2EF/REF CT, 1VT, 39 BINARY INP./ 14 BINARY OUTP. 32 LEDS MEASURING INPUT: 1/5 A 63.5/ 110V, 50/60HZ REGION WORLD, LANGUAGE: ENGLISH USB FRONT PORT, RS485 REAR PORT IEC 60870-5-103 AND MODBUS RTU (USER SELECTABLE SETTING) PROTECT. FUNCT.: STANDARD + UNDERCURRENT (37) NEGATIVE PHASE SEQUENCY O/C THERMAL OVERLOAD (49) INSTANTANEOUS PHASE FAULT O/C INSTANTANEOUS EARTH FAULT TIME DELAYED PHASE FAULT O/C + VOLTAGE RELATED FUNCTIONS | |
7SR2424-2.A12-0BA0 | DUOBIAS-M TRANSFORMER DIFFERENTIAL RELAY (2 WINDING) E12 CASE, 6CT, 2EF/REF CT, 1VT, 39 BINARY INP./ 14 BINARY OUTP. 32 LEDS MEASURING INPUT: 1/5 A 63.5/ 110V, 50/60HZ REGION WORLD, LANGUAGE: ENGLISH USB FRONT PORT, RS485 REAR PORT IEC 60870-5-103, MODBUS RTU AND DNP 3.0(USER SELECTAB. SETTING) PROTECTION FUNCTION: STANDARD VERSION + UNDERCURRENT (37) NEGATIVE PHASE SEQUENCY O/C THERMAL OVERLOAD (49) INSTANTANEOUS PHASE FAULT O/C INSTANTANEOUS EARTH FAULT TIME DELAYED PHASE FAULT O/C | |
7SR2424-2.A12-0CA0 | DUOBIAS-M TRANSFORMER DIFFERENTIAL RELAY (2 WINDING) E12 CASE, 6CT, 2EF/REF CT, 1VT, 39 BINARY INP./ 14 BINARY OUTP. 32 LEDS MEASURING INPUT: 1/5 A 63.5/ 110V, 50/60HZ REGION WORLD, LANGUAGE: ENGLISH USB FRONT PORT, RS485 REAR PORT IEC 60870-5-103, MODBUS RTU AND DNP 3.0(USER SELECTAB. SETTING) PROTECT. FUNCT.: STANDARD + UNDERCURRENT (37) NEGATIVE PHASE SEQUENCY O/C THERMAL OVERLOAD (49) INSTANTANEOUS PHASE FAULT O/C INSTANTANEOUS EARTH FAULT TIME DELAYED PHASE FAULT O/C + VOLTAGE RELATED FUNCTIONS | |
7SR2424-2.A21-0AA0 | DUOBIAS-M TRANSFORMER DIFFERENTIAL RELAY (2 WINDING) E12 CASE, 6CT, 2EF/REF CT, 1VT, 39 BINARY INP./ 14 BINARY OUTP. 32 LEDS MEASURING INPUT: 1/5 A 63.5/ 110V, 50/60HZ REGION WORLD, LANGUAGE: ENGLISH USB FRONT PORT, RS485 REAR PORT + REAR F/O ST CONNECTORS (X2) AND IRIG-B IEC 60870-5-103 AND MODBUS RTU (USER SELECTABLE SETTING) PROTECTION FUNCTION: STANDARD VERSION | |
7SR2424-2.A21-0BA0 | DUOBIAS-M (2 WINDING) TRANSFORMER DIFFERENTIAL RELAY E12 CASE, 6CT, 2EF/REF CT, 1VT, 39 BINARY INP./ 14 BINARY OUTP. 32 LEDS MEASURING INPUT: 1/5 A 63.5/ 110V, 50/60HZ REGION WORLD, LANGUAGE: ENGLISH USB FRONT PORT, RS485 REAR PORT + REAR F/O ST CONNECTORS (X2) AND IRIG-B IEC 60870-5-103 AND MODBUS RTU (USER SELECTABLE SETTING) PROTECT. FUNCT.:STANDARD + UNDERCURRENT (37) NEGATIVE PHASE SEQUENCY O/C THERMAL OVERLOAD (49) INSTANTANEOUS PHASE FAULT O/C INSTANTANEOUS EARTH FAULT TIME DELAYED PHASE FAULT O/C |