7SR2422-2MA11-0BA0
Manufacturer: SIEMENS
Price: On Request
Transformer differential protection (Duobias- M) E8 enclosure, 6 curr. trans., 2 ES/EDS curr. trans., 1 volt. trans. 9 BI / 6 BO, 16 LEDs Measuring inputs: 1/5A, 40 to 160V, 50/60Hz Auxiliary voltage 24 - 250V DC / 100- 230V AC Threshold binary input: 19V DC USB interface at front, RS485 interface at rear, Protocol: IEC 60870-5-103 and Modbus RTU (adjustable) Protective function: Standard version + Option B
Similar items in same category:
7SR2422-2BA21-0BA0 | DUOBIAS-M (2 WINDING) TRANSFORMER DIFFERENTIAL RELAY E8 CASE, 6CT, 2EF/REF CT, 1VT, 9 BINARY INPUTS/ 6 BINARY OUTP. 16 LEDS MEASURING INPUT: 1/5 A 63.5/ 110V, 50/60HZ REGION WORLD, LANGUAGE: ENGLISH USB FRONT PORT, RS485 REAR PORT + REAR F/O ST CONNECTORS (X2) AND IRIG-B IEC 60870-5-103 AND MODBUS RTU (USER SELECTABLE SETTING) PROTECT. FUNCT.:STANDARD + UNDERCURRENT (37) NEGATIVE PHASE SEQUENCY O/C THERMAL OVERLOAD (49) INSTANTANEOUS PHASE FAULT O/C INSTANTANEOUS EARTH FAULT TIME DELAYED PHASE FAULT O/C 30 TO 220V DC AUXILLIARY, BINARY INPUT THRESHOLD 88V DC | |
7SR2422-2BA32-0CA0 | DUOBIAS-M TRANSFORMER DIFFERENTIAL RELAY E8 CASE ,6 CT,2EF/REF CT, 1VT 9 BINARY INP. / 6 BINARY OUTP. 16 LEDS MEASURING INPUT: 1/5A, 63,5/110V, 50/60HZ AUXILIARY VOLTAGE: 30 TO 220V DC, BINARY INPUT THRESHOLD 88V DC USB FRONT PORT, RS485 REAR PORT PLUS REAR RS485 AND IRIG-B PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) PROTECTION FUNCTION: STANDARD VERSION + OPTION C | |
7SR2422-2BA77-0AA0 | DUOBIAS-M TRANSFORMER DIFFERENTIAL RELAY E8 CASE ,6 CT,2EF/REF CT, 1VT 9 BINARY INP. / 6 BINARY OUTP. 16 LEDS MEASURING INPUT: 1/5A, 63,5/110V, 50/60HZ AUXILIARY VOLTAGE: 30 TO 220V DC, BINARY INPUT THRESHOLD 88V DC USB FRONT PORT, RS485 REAR PORT PLUS REAR ELECTR. ETHERNET RJ45 PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) AND IEC 61850 PROTECTION FUNCTION: STANDARD VERSION | |
7SR2422-2MA11-0AA0 | ||
7SR2422-2MA11-0CA0 | ||
7SR2422-2MA21-0BA0 | DUOBIAS-M (2 WINDING) TRANSFORMER DIFFERENTIAL RELAY E8 CASE, 6CT, 2EF/REF CT, 1VT, 9 BINARY INPUTS/ 6 BINARY OUTP. 16 LEDS MEASURING INPUT: 1/5 A 63.5/ 110V, 50/60HZ REGION WORLD, LANGUAGE: ENGLISH USB FRONT PORT, RS485 REAR PORT + REAR F/O ST CONNECTORS (X2) AND IRIG-B IEC 60870-5-103 AND MODBUS RTU (USER SELECTABLE SETTING) PROTECT. FUNCT.:STANDARD + UNDERCURRENT (37) NEGATIVE PHASE SEQUENCY O/C THERMAL OVERLOAD (49) INSTANTANEOUS PHASE FAULT O/C INSTANTANEOUS EARTH FAULT TIME DELAYED PHASE FAULT O/C AUXILIARY VOLTAGE: 24 - 250V DC / 100-230V AC BINARY INPUT THRESHOLD 19V DC (RATED: 24-250V DC) | |
7SR2422-2MA41-0BA0 | DUOBIAS-M (2 WINDING) TRANSFORMER DIFFERENTIAL RELAY E8 CASE, 6CT, 2EF/REF CT, 1VT, 9 BINARY INPUTS/ 6 BINARY OUTP. 16 LEDS MEASURING INPUT: 1/5 A 63.5/ 110V, 50/60HZ REGION WORLD, LANGUAGE: ENGLISH USB FRONT PORT, RS485 REAR PORT + REAR RS232 (X1) AND IRIG-B IEC 60870-5-103 AND MODBUS RTU (USER SELECTABLE SETTING) PROTECT. FUNCT.:STANDARD + UNDERCURRENT (37) NEGATIVE PHASE SEQUENCY O/C THERMAL OVERLOAD (49) INSTANTANEOUS PHASE FAULT O/C INSTANTANEOUS EARTH FAULT TIME DELAYED PHASE FAULT O/C AUXILIARY VOLTAGE: 24 - 250V DC / 100-230V AC BINARY INPUT THRESHOLD 19V DC (RATED: 24-250V DC) | |
7SR2422-2MA77-0CA0 | Transformer differential protection (Duobias- M) E8 enclosure, 6 curr. trans., 2 ES/EDS curr. trans., 1 volt. trans. 9 BI / 6 BO, 16 LEDs Measuring inputs: 1/5A, 40 to 160V, 50/60Hz Auxiliary voltage 24 - 250V DC / 100- 230V AC Threshold binary input: 19V DC USB interface at front, RS485 interface rear, + electr. Ethernet RJ45 Protocol: IEC 60870-5-103 and Modbus RTU and DNP3.0 (adjustable) and IEC 61850 Protective function: Standard version + Option C |