• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.
7SR1003-1MA20-2DA1

7SR1003-1MA20-2DA1

Manufacturer: SIEMENS

Price: On Request

ARGUS overcurrent relay Non-directional, size 4 molded case, 4 CT, 10 LEDs, 9 binary inputs, 6 binary outputs, Measuring input: 1/5 A, 50/60 Hz, auxiliary voltage: DC 24 - 240 V, AC 48 - 240 V, binary input threshold 19 V DC, Standard version - no cover Communication: Front port: USB and rear: RS485 supporting IEC 60870-5-103 or Modbus RTU or DNP 3.0. . Front fascia: w. breaker control pushbuttons Protection function: Standard version plus autoreclose (79), 3 nos. additional BI


Similar items in same category:
7SR1003-1LB20-2DA0 7SR1003-1LB20-2DA0 ARGUS overcurrent relay Non-directional, size 4 molded case, 4 CT, 10 LEDs, 6 binary inputs/ 6 binary outp. Measuring input: 1/5 A, 50/60 Hz auxiliary voltage: 60 to 240 V AC/DC, binary input threshold 44 V AC/DC Plastic cover with 1 pushbutton for test/reset Communication: Front port: USB and rear: RS485 supporting IEC 60870-5-103 or Modbus RTU or DNP 3.0. Front fascia: w. breaker control pushbuttons Protection function: Standard version plus autoreclose (79)
7SR1003-1LB20-2DB0 7SR1003-1LB20-2DB0 ARGUS overcurrent relay Conformal coating on PCBA Non-directional, size 4 molded case, 4 CT, 10 LEDs, 6 binary inputs/ 6 binary outp. Measuring input: 1/5 A, 50/60 Hz auxiliary voltage: 60 to 240 V AC/DC, binary input threshold 44 V AC/DC Plastic cover with 1 pushbutton for test/reset Communication: Front port: USB and rear: RS485 supporting IEC 60870-5-103 or Modbus RTU or DNP 3.0. Front fascia: w. breaker control pushbuttons Protection function: Standard version plus autoreclose (79)
7SR1003-1MA20-2CA1 7SR1003-1MA20-2CA1 Argus Non-direct. overcurrent relay Size 4 molded casing, 4 CT, 10 LEDs, 9 binary inputs/ 6 binary outputs Measuring input: 1/5A, 50/60 Hz Auxil. voltage: DC 24 - 240 V / AC 48-240 V, binary input tresh. 19 VDC Standard version - no cover Communication: Front port: USB and rear: RS485 supporting IEC 60870-5-103 or Modbus RTU or DNP 3.0 Front fascia: w. breaker control pushbuttons Protection function: standard version, 3 nos.additional BI
7SR1003-1MA20-2CB1 7SR1003-1MA20-2CB1 ARGUS overcurrent relay Conformal coating on PCBA Non-directional, size 4 molded case, 4 CT, 10 LEDs, 9 binary inputs/ 6 binary outp. Measuring input: 1/5 A, 50/60 Hz, auxiliary voltage: DC 24-240V/ AC 48-240V, binary input threshold 19 V DC, Standard version - no cover Communication: Front port: USB and rear: RS485 supporting IEC 60870-5-103 or Modbus RTU or DNP 3.0. Front fascia: w. breaker control pushbuttons protection function: standard version, 3 nos. additional BI
7SR1003-1MA20-2DB1 7SR1003-1MA20-2DB1 ARGUS overcurrent relay Conformal coating on PCBA Non-directional, size 4 molded case, 4 CT, 10 LEDs, 9 binary inputs/ 6 binary outp. Measuring input: 1/5 A, 50/60 Hz, auxiliary voltage: DC 24 - 240 V, AC 48 - 240 V, binary input threshold 19 V DC, Standard version - no cover Communication: Front port: USB and rear: RS485 supporting IEC 60870-5-103 or Modbus RTU or DNP 3.0. Front fascia: w. breaker control pushbuttons Protection function: Standard version plus autoreclose (79), 3 nos. additional BI
7SR1003-1MB20-2CA1 7SR1003-1MB20-2CA1 ARGUS overcurrent relay Non-directional, size 4 molded case, 4 CT, 10 LEDs, 9 binary inputs/ 6 binary outp. Measuring input: 1/5 A, 50/60 Hz auxiliary voltage: 24- 240 V DC, AC 48-240V,binary input threshold 19 V DC Plastic cover with 1 pushbutton for test/reset Communication: Front port: USB and rear: RS485 supporting IEC 60870-5-103 or Modbus RTU or DNP 3.0. Front fascia: w. breaker control pushbuttons protection function: standard version, 3 nos. additional BI
7SR1003-1MB20-2CB1 7SR1003-1MB20-2CB1 ARGUS overcurrent relay Conformal coating on PCBA Non-directional, size 4 molded case, 4 CT, 10 LEDs, 9 binary inputs/ 6 binary outp. Measuring input: 1/5 A, 50/60 Hz, auxiliary voltage DC 24 - 240 V, AC 48 -240 V binary input threshold 19 V DC Plastic cover with 1 pushbutton for test/reset Communication: Front port: USB and rear: RS485 supporting IEC 60870-5-103 or Modbus RTU or DNP 3.0. Front fascia: w. breaker control pushbuttons protection function: standard version, 3 nos. additional BI
7SR1003-1MB20-2DA1 7SR1003-1MB20-2DA1 ARGUS overcurrent relay Non-directional, size 4 molded case, 4 CT, 10 LEDs, 9 binary inputs/ 6 binary outp. Measuring input: 1/5 A, 50/60 Hz, auxiliary voltage: DC 24 - 240 V, AC 24 - 240 V , binary input threshold 19 V DC, Plastic cover with 1 pushbutton for test/reset Communication: Front port: USB and rear: RS485 supporting IEC 60870-5-103 or Modbus RTU or DNP 3.0. , Front fascia: w. breaker control pushbuttons Protection function: Standard version plus autoreclose (79), 3 nos. additional BI