7SK806.-.....-...0
Manufacturer: SIEMENS
Price: On Request
Motor protection Enclosure 1/6 19", 4 x I, 3 x U, 3 BI, 5 BQ (2 changeover contacts) 5 temperature sensors 1 live contact
Similar items in same category:
7SK8042-5EB96-3HE0 L0S | MOTOR PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IEE (SENSITIVE) = 0,001 TO 1,6 A/ 0,005 TO 8A RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/ 220V, AC 115V/ 230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) IEC 61850, 100MBIT ETHERNET, WITH INTEGRATED SWITCH OPTICAL, DOUBLE, LC-CONNECTOR (FROM OCT. 09) INTERFACE, PORT A (ON BOTTOM OF DEVICE) WITH ETHERNET INTERFACE (DIGSI, RTD BOX, NOT IEC61850) RJ45 CONNECTOR METERING: FAULT RECORDING, AVERAGE VALUES, MIN/MAX VALUES FUNKTIONALITY: TOC PHASE OVERCURRENT (50/51) I>, I>>,I>>>,IP TIME OVERCURR.PROTECTION GROUND 50N/51N, IE>,IE>>,IE>>>,IEP GROUND FAULT PROTECTION IEE>, IEE>>, IEEP, OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION LOCK OUT (86) STARTING TIME SUPERVISION (48) UNDERCURRENT MONITORING (37) RESTART INHIBIT (66/86) LOCKED ROTOR PROTECTION (14) LOAD JAM PROTECTION (51M) ADDITIONAL FUNCTIONS: DIRECT. SENSITIVE GROUND FAULT VOLTAGE A. FREQUENCY PROTECTION | |
7SK805.-.....-...0 | Motor protection Enclosure 1/6 19", 4 x I, 3 BI, 5 BQ (2 changeover contacts) 5 temperature sensors 1 live contact | |
7SK8052-5BC10-3HD0 | MOTOR PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 BI, 5 BO, (2 CHANGEOVER) 5 RTD INPUTS 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IEE (SENSITIVE) = 0,001 TO 1,6 A/ 0,005 TO 8A RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/ 220V, AC 115V/ 230V SURFACE-MOUNTING CASE SCREW-TYPE TERMINAL REGION US,ANSI,LANGUAGE US-ENGL (LANGUAGE CHANGEABLE) US-FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) IEC60870-5-103 O. DIGSI4/MODEM, ELECTRICAL RS232 NO SYSTEM PORT A METERING: FAULT RECORDING, AVERAGE VALUES, MIN/MAX VALUES FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>,I>>,I>>>,IP, TIME OVERCURR.PROTECTION GROUND 50N/51N, IE>, IE>>,IE>>>, IEP GROUND FAULT PROTECTION IEE>.IEE>>,IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION LOCK OUT (86) STARTING TIME SUPERVISION (48) UNDERCURRENT MONITORING (37) RESTART INHIBIT (66/86) LOCKED ROTOR PROTECTION (14) LOAD JAM PROTECTION (51M) MOTOR STATISTICS PARAMETER CHANGEOVER MONITORING FUNCTIONS | |
7SK8052-5EB00-1HD0 | MOTOR PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 BI, 5 BO, (2 CHANGEOVER) 5 RTD INPUTS 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IEE (SENSITIVE) = 0,001 TO 1,6 A/ 0,005 TO 8A RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/ 220V, AC 115V/ 230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT NO SYSTEM PORT NO SYSTEM PORT A METERING: FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>,I>>,I>>>,IP, TIME OVERCURR.PROTECTION GROUND 50N/51N, IE>, IE>>,IE>>>, IEP GROUND FAULT PROTECTION IEE>.IEE>>,IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION LOCK OUT (86) STARTING TIME SUPERVISION (48) UNDERCURRENT MONITORING (37) RESTART INHIBIT (66/86) LOCKED ROTOR PROTECTION (14) LOAD JAM PROTECTION (51M) MOTOR STATISTICS PARAMETER CHANGEOVER MONITORING FUNCTIONS | |
7SK8061-1EB90-1HE0 L0A | Motor protection Enclosure 1/6 19", 4 x I, 3 x U, 3 BI, 5 BQ (2 changeover contacts) 5 temperature sensors 1 live contact Measuring inputs: Iph = 1 A / 5 A, Ie = 1 A / 5 A Rated auxiliary power: DC 24, 48 V Installation enclosure Screw terminals Region world, IEC/ANSI English (language can be changed) Front membrane standard System interface port B (device underside, rear) PROFIBUS DP slave, electr. RS 485 Without system interface, Port A Measurement: fault recording Functionality: XMZ Overcurrent time sw. XMZ PH(50/51) I>, I>>, I>>>, Ip Ground fault protection XMZ GROUND (50N/51N) Ie>, Ie>>, Ie>>>,Iep Ground fault/Ground short circuit prot. Iee>, Iee>>, Ieep Overload protection (49) Trip circuit monitoring (74TC) Circuit breaker failure protection (50BF), Load unbalance protection (46) Lock out (86) Start up time monitoring (48) Undercurrent monitoring (37) Reclosing lockout (66/86) Rotor blocking protection (14) Load step protection (51M) Supplementary function: Ground fault direction detection(*) | |
7SK8061-1EB90-1HE0 L0D | Motor protection Enclosure 1/6 19", 4 x I, 3 x U, 3 BI, 5 BQ (2 changeover contacts) 5 temperature sensors 1 live contact Measuring inputs: Iph = 1 A / 5 A, Ie = 1 A / 5 A Rated auxiliary power: DC 24, 48 V Installation enclosure Screw terminals Region world, IEC/ANSI English (language can be changed) Front membrane standard System interface port B (device underside, rear) Modbus, electrical RS 485 Without system interface, Port A Measurement: fault recording Functionality: XMZ Overcurrent time sw. XMZ PH(50/51) I>, I>>, I>>>, Ip Ground fault protection XMZ GROUND (50N/51N) Ie>, Ie>>, Ie>>>,Iep Ground fault/Ground short circuit prot. Iee>, Iee>>, Ieep Overload protection (49) Trip circuit monitoring (74TC) Circuit breaker failure protection (50BF), Load unbalance protection (46) Lock out (86) Start up time monitoring (48) Undercurrent monitoring (37) Reclosing lockout (66/86) Rotor blocking protection (14) Load step protection (51M) Supplementary function: Ground fault direction detection(*) | |
7SK8061-1EB90-1HE0L0A | motor protection, enclosure 1/6 19", 4 x I, 3 x V, 3 BI, 5 BO (2 change-over contacts), 1 live contact, 5 temperature sensors, measuring inputs: Iph = 1 A/5 A, Ie = 1 A/5 A, rated auxiliary power: DC 24, 48 V, installation enclosure, screw terminals region world, IEC / ANSI, language English (can be changed), front membrane standard, system interface port B (device underside, rear) PROFIBUS DP slave, electrical RS485 without system interface Port A, measurement: fault recording, functionality: basic version + function package 'HE | |
7SK8061-1EB90-1HE0L0D | motor protection, enclosure 1/6 19", 4 x I, 3 x V, 3 BI, 5 BO (2 change-over contacts), 1 live contact, 5 temperature sensors, measuring inputs: Iph = 1 A/5 A, Ie = 1 A/5 A, rated auxiliary power: DC 24, 48 V, installation enclosure, screw terminals region world, IEC / ANSI, language English (can be changed), front membrane standard, system interface port B (device underside, rear) Modbus, electrical RS485 without system interface Port A, measurement: fault recording, functionality: basic version + function package 'HE |