7SJ8131-....
Manufacturer: SIEMENS
Price: On Request
UEBERSTROMZEITSCHUTZ, 3POLIG 1A 50HZ 0,5-5S
Similar items in same category:
7SJ8113-5EB90-3FA0 L0D | OVERCURRENT PROTECTION RELAY FOR LOW POWER CURRENT TRANSFORMERS HOUSING 1/6 19", 4 X I, 3 BI, 5 BO, (2 CHANGEOVER/FORM C), 1 LIVE STATUS CONTACT 4 X LOW POWER CURRENT TRANSFORMER INPUT RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/ 220V/250V AC 115V/ 230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH STANDARD FRONT SYSTEM PORT, PORT B (AT BOTTOM OF DEVICE, REAR) MODBUS, ELECTRICAL RS485 NO SYSTEM PORT A METERING: FAULT RECORDING, AVERAGE VALUES, MIN/MAX VALUES FUNCTIONALITY: PHASE OVERCURRENT (50/51) I>,I>>,I>>>,IP, TIME OVERCURR.PROTECTION GROUND 50N/51N, IE>, IE>>,IE>>>, IEP SENSITIVE GROUND FAULT PROTECT. IEE>.IEE>>,IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) PARAMETER CHANGEOVER MONITORING FUNCTIONS CONTROL OF CIRCUIT BREAKER FLEXIBLE PROTECTION FUNCTIONS (CURRENT PARAMETERS) INRUSH RESTRAINT . | |
7SJ8113-5EB90-3FA0L0A | overcurrent protection for low-power current transformer, enclosure 1/6 19", 4 x I, 3 BI, 5 BO (2 change-over contacts), 1 live contact, 4 x low-power current transformer inputs rated auxiliary power: 60 to 250 V DC,115 V AC, 230 V AC installation enclosure, screw terminals region world, IEC / ANSI, language English (can be changed), front membrane standard, system interface port B PROFIBUS DP slave, electrical RS485 measurement: fault recording, mean value formation, min./max. values, functionality: basic version, without automatic reclosing, without fault locator | |
7SJ8113-5EB90-3FA0L0D | overcurrent protection for low-power current transformer, enclosure 1/6 19", 4 x I, 3 BI, 5 BO (2 change-over contacts), 1 live contact, 4 x low-power current transformer inputs rated auxiliary power: 60 to 250 V DC,115 V AC, 230 V AC installation enclosure, screw terminals region world, IEC / ANSI, language English (can be changed), front membrane standard, system interface port B Modbus, electrical RS485 measurement: fault recording, mean value formation, min./max. values, functionality: basic version, without automatic reclosing, without fault locator | |
7SJ8130-.... | UEBERSTROMZEITSCHUTZ, 3POLIG 1A 50HZ 0,3-2,5S | |
7SJ8132-.... | UEBERSTROMZEITSCHUTZ, 3POLIG 1A 50HZ 1-10S | |
7SJ8143-1EB90-3FC0 L0A | OVERCURRENT PROTECTION RELAY FOR LOW POWER CURRENT TRANSFORMERS HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER/FORM C), 1 LIVE STATUS CONTACT 4 X LOW POWER CURRENT TRANSFORMER INPUT RATED AUXILIARY VOLTAGE DC 24V/ 48V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH STANDARD FRONT SYSTEM PORT, PORT B (AT BOTTOM OF DEVICE, REAR) PROFIBUS DP SLAVE, ELECTR.RS485 NO SYSTEM PORT A METERING: FAULT RECORDING, AVERAGE VALUES, MIN/MAX VALUES FUNCTIONALITY: BASIC FUNCTIONALITY + DIRECTIONAL PHASE + GROUND OVERCURRENT , DIRECT. SENSITIVE GROUND FAULT, VOLTAGE AND FREQUENCY PROTECT. . | |
7SJ8143-1EB90-3FC0 L0D | OVERCURRENT PROTECTION RELAY FOR LOW POWER CURRENT TRANSFORMERS HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER/FORM C), 1 LIVE STATUS CONTACT 4 X LOW POWER CURRENT TRANSFORMER INPUT RATED AUXILIARY VOLTAGE DC 24V/ 48V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH STANDARD FRONT SYSTEM PORT, PORT B (AT BOTTOM OF DEVICE, REAR) MODBUS, ELECTRICAL RS485 NO SYSTEM PORT A METERING: FAULT RECORDING, AVERAGE VALUES, MIN/MAX VALUES FUNCTIONALITY: BASIC FUNCTIONALITY + DIRECTIONAL PHASE + GROUND OVERCURRENT , DIRECT. SENSITIVE GROUND FAULT, VOLTAGE AND FREQUENCY PROTECT. . | |
7SJ8143-1EB90-3FC0L0A | overcurrent protection for low-power current transformer enclosure 1/6 19", 4 x I, 3 x V, 7 BI, 8 BO (2 change-over contacts), 1 live contact, 4 x low-power current transformer inputs rated auxiliary power: 24 - 48 V DC, installation enclosure, screw terminals region world, IEC / ANSI, language English (can be changed), front membrane standard, system interface port B PROFIBUS DP slave, electrical RS485 measurement: fault recording, mean value formation, min./max. values, functionality: basic version + function package 'FC', without automatic reclosing, without(*) |