7SJ6325-5EB62-3FG0
Manufacturer: SIEMENS
Price: On Request
MULTIFUNCTION PROTECTIVE RELAY
BAY CONTROLLER W.LOCATED CONTR.
BACKFIT GRAPHIC DISPLAY,
14 PROGRAMMABLE LED,
KEY SWITCHES,
CASE 1/2 19", 24BI, 11BO,
2 POWER RELAYS, (4 CONTACTS)
1 WATCHDOG CONTACT
MEASURING INPUTS (3 X U,4 X I):
IPH = 5A, IE = 5A(MIN. = 0.25A)
SUPPLY VOLTAGE:DC 110V TO 250V,
AC 115V TO 230V,
TRIGG.LEVEL BINARY INPUT DC 88V
FLUSH MOUNTING CASE,
SCREW TERMINALS
LANGUAGE ENGLISH, 50/60HZ,
IEC/ANSI, REGION WORLD,
(LANGUAGE CHANGEABLE)
SYSTEM PORT
(ON REAR OF DEVICE) PORT B
PROFIBUS FMS SLAVE, FIBER,
DOUBLE LOOP, ST-PLUG
DIGSI 4/MODEM PORT
(ON REAR OF DEVICE) PORT C
DIGSI 4, RS485
METERING: PEAK VALUES,
AVERAGE METER, MIN/MAX-VALUES,
FAULT RECORDING
FUNCTIONALITY: TOC+
DIRECTIONAL TOC+V/F
PHASE OVERCURRENT (50/51):
I>,I>>,IP,REVERSE INTERLOCKING,
INDEPENDENT OF PAHSE ROTATION,
GROUND OVERCURRENT (50/51N):
IE>, IEE>>, IEP,
DIRECTIONAL TIME OVERCURRENT
(67/67N WITH 50N/51N),
PHASE ROTATION (47),OVERLOAD
PROTECT. W.2 TIME CONSTANTS(49)
TRIP CIRCUIT SUPERVISION (74TC)
BREAKER FAILURE PROTECT. (50BF)
COLD LOAD PICKUP,
INRUSH BLOCKING,
NEGATIVE SEQUENCE (46)
LOCK OUT (86), OVER/UNDER
FREQU. (81U/O), UNDER VOLTAGE
(27-1,27-2),OVER VOLTAGE (59-1)
WITHOUT AUTO-RECLOSURE
Similar items in same category:
7SJ6325-4EB90-3FE0 L0A | MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 24BI, 11BO, 2 POWER RELAYS, (4 CONTACTS) 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 5A, IE = 5A(MIN. = 0.25A) SUPPLY VOLTAGE: DC 60V TO 125V, TRIGG.LEVEL BINARY INPUT DC 19V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B PROFIBUS DP SLAVE, RS485 WITHOUT DIGSI 4/MODEM PORT METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY: TOC+V/F PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>,IE>>,IEP, OVERLOAD PROTECT. WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTEC. (50BF), COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86), OVER7UNDER FREQUENCY (81U/O), UNDER VOLTAGE (27-1,27-2), OVER VOLTAGE (59-1) WITHOUT AUTO-RECLOSURE | |
7SJ6325-5EB02-3FE1 | MULTIFUNCTION PROTECTIVE RELAY BAY CONTROLLER W.LOCATED CONTR. BACKFIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 24BI, 11BO, 2 POWER RELAYS, (4 CONTACTS) 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 5A, IE = 5A(MIN. = 0.25A) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) NO SYSTEM PORT DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, RS485 METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY: TOC+V/F PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>,IE>>,IEP, OVERLOAD PROTECT. WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTEC. (50BF), COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86), OVER7UNDER FREQUENCY (81U/O), UNDER VOLTAGE (27-1,27-2), OVER VOLTAGE (59-1) WITH AUTOMATIC RECLOSING | |
7SJ6325-5EB22-3FA2 | MULTIFUNCTION PROTECTIVE RELAY BAY CONTROLLER W.LOCATED CONTR. BACKFIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 24BI, 11BO, 2 POWER RELAYS, (4 CONTACTS) 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 5A, IE = 5A(MIN. = 0.25A) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC PROTOCOL, RS 485 DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, RS485 METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>,IEP, OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) UNDERCURRENT MONITORING (37), DISPLACEMENT VOLTAGE (59N/64), BREAKER FAILURE PROTECT. (50BF) COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86) FAULT LOCATOR | |
7SJ6325-5EB22-3FE0 | MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 24BI, 11BO, 2 POWER RELAYS, (4 CONTACTS) 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 5A, IE = 5A(MIN. = 0.25A) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) System interface Rear of the device port B IEC protocol, electrical RS 485 DIGSI 4/modem interface Rear of the device port C DIGSI 4, electrical RS 485 METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY: TOC+V/F PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>,IE>>,IEP, OVERLOAD PROTECT. WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTEC. (50BF), COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86), OVER7UNDER FREQUENCY (81U/O), UNDER VOLTAGE (27-1,27-2), OVER VOLTAGE (59-1) Without automatic reclosing | |
7SJ6325-5EB92-3FE1 L0S | MULTIFUNCTION PROTECTIVE RELAY BAY CONTROLLER W.LOCATED CONTR. BACKFIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 24BI, 11BO, 2 POWER RELAYS, (4 CONTACTS) 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 5A, IE = 5A(MIN. = 0.25A) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 61850,100 MBIT ETHERNET WITH INTEGRATED SWITCH OPTICAL, DOUBLE, LC-CONNECTOR (FROM OCT. 09) DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, RS485 METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY: TOC+V/F PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>,IE>>,IEP, OVERLOAD PROTECT. WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTEC. (50BF), COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86), OVER7UNDER FREQUENCY (81U/O), UNDER VOLTAGE (27-1,27-2), OVER VOLTAGE (59-1) WITH AUTOMATIC RECLOSING | |
7SJ6325-5EB92-3HA0 L0D | MULTIFUNCTION PROTECTIVE RELAY BAY CONTROLLER W.LOCATED CONTR. BACKFIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 24BI, 11BO, 2 POWER RELAYS, (4 CONTACTS) 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 5A, IE = 5A(MIN. = 0.25A) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B MODBUS, RS485 DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, RS485 METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY: TOC+ MOTOR PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>,IEP, OVERLOAD PROTECTION WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTECT.(50BF), COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46) LOCK OUT (86) MOTOR PROTECTION: UNDERCURRENT (37), NEGATIVE SEQUENCE (46), START UP SUPERVERSION (48), START UP BLOCK./LOCKOUT (66/86) WITHOUT AUTO-RECLOSURE | |
7SJ6326-.....-.... | MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 24BI, 11BO, 2 POWER RELAYS, (4 CONTACTS) 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 5A, IE = SENSITIVE (MIN. = 0.001A) | |
7SJ6326-.B...-.... | MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 24BI, 11BO, 2 POWER RELAYS, (4 CONTACTS) 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 5A, IE = SENSITIVE (MIN. = 0.001A) SURFACE MOUNTING CASE, TERMINALS ON TOP AND BOTTOM |