Searching...
Nothing found.
[[ item.description.prodDescription ]]
This Product is on your Inquiry List.
7SJ6321-5EA32-3FE1
Manufacturer: SIEMENS
Price: On Request
MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 24BI, 11BO, 2 POWER RELAYS, (4 CONTACTS) 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 1A, IE = 1A(MIN. = 0.05A) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE GERMAN, 50HZ, IEC, REGION DE,(LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC PROTOCOL, 820NM FIBER, ST-PLUG DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, RS485 METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY: TOC+V/F PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>,IE>>,IEP, OVERLOAD PROTECT. WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTEC. (50BF), COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86), OVER7UNDER FREQUENCY (81U/O), UNDER VOLTAGE (27-1,27-2), OVER VOLTAGE (59-1) WITH AUTOMATIC RECLOSING
Similar items in same category:
7SJ6321-4EB92-3FA0 L0A | MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 24BI, 11BO, 2 POWER RELAYS, (4 CONTACTS) 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 1A, IE = 1A(MIN. = 0.05A) SUPPLY VOLTAGE: DC 60V TO 125V, TRIGG.LEVEL BINARY INPUT DC 19V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B PROFIBUS DP SLAVE, RS485 DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, RS485 METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>,IEP, OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) UNDERCURRENT MONITORING (37), DISPLACEMENT VOLTAGE (59N/64), BREAKER FAILURE PROTECT. (50BF) COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86) WITHOUT AUTO-RECLOSURE | |
7SJ6321-4EB92-3FC0 L0A | MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 24BI, 11BO, 2 POWER RELAYS, (4 CONTACTS) 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 1A, IE = 1A(MIN. = 0.05A) SUPPLY VOLTAGE: DC 60V TO 125V, TRIGG.LEVEL BINARY INPUT DC 19V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B PROFIBUS DP SLAVE, RS485 DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, RS485 METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY:TOC+DIRECT. TOC+ PHASE OVERCURRENT (50/51): I>,I>>,IP, REVERSE INTERLOCKING INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>, IEP, DIRECTIONAL TIME OVERCURRENT (67/67N WITH 50N/51N), PHASE ROTATION (47), OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTECT. (50BF) COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46) LOCK OUT (86) WITHOUT AUTO-RECLOSURE | |
7SJ6321-5CB00-3FA0 | ||
7SJ6321-5CB00-3FG0 | ||
7SJ6321-5EB00-3FA0 | MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 24BI, 11BO, 2 POWER RELAYS, (4 CONTACTS) 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 1A, IE = 1A(MIN. = 0.05A) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) No system interface without DIGSI 4/modem interface METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>,IEP, OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) UNDERCURRENT MONITORING (37), DISPLACEMENT VOLTAGE (59N/64), BREAKER FAILURE PROTECT. (50BF) COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86) Without automatic reclosing | |
7SJ6321-5EB20-3FA0 | MULTIFUNCTION PROTECTIVE RELAY BAY CONTROLLER W.LOCATED CONTR. BACKFIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 24BI, 11BO, 2 POWER RELAYS, (4 CONTACTS) 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 1A, IE = 1A(MIN. = 0.05A) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC PROTOCOL, RS 485 WITHOUT DIGSI 4/MODEM PORT METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>,IEP, OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) UNDERCURRENT MONITORING (37), DISPLACEMENT VOLTAGE (59N/64), BREAKER FAILURE PROTECT. (50BF) COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86) WITHOUT AUTO-RECLOSURE | |
7SJ6321-5EB20-3FE0 | MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 24BI, 11BO, 2 POWER RELAYS, (4 CONTACTS) 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 1A, IE = 1A(MIN. = 0.05A) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC PROTOCOL, RS 485 WITHOUT DIGSI 4/MODEM PORT METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY: TOC+V/F PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>,IE>>,IEP, OVERLOAD PROTECT. WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTEC. (50BF), COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86), OVER7UNDER FREQUENCY (81U/O), UNDER VOLTAGE (27-1,27-2), OVER VOLTAGE (59-1) WITHOUT AUTO-RECLOSURE | |
7SJ6321-5EB22-3FC0 | MULTIFUNCTION PROTECTIVE RELAY BAY CONTROLLER W.LOCATED CONTR. BACKFIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 24BI, 11BO, 2 POWER RELAYS, (4 CONTACTS) 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 1A, IE = 1A(MIN. = 0.05A) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC PROTOCOL, RS 485 DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, RS485 METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY:TOC+DIRECT. TOC+ PHASE OVERCURRENT (50/51): I>,I>>,IP, REVERSE INTERLOCKING INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>, IEP, DIRECTIONAL TIME OVERCURRENT (67/67N WITH 50N/51N), PHASE ROTATION (47), OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTECT. (50BF) COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46) LOCK OUT (86) WITHOUT AUTO-RECLOSURE |