• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.
7SJ6312-.B...-....

7SJ6312-.B...-....

Manufacturer: SIEMENS

Price: On Request

MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 11BI, 8BO, WITHOUT POWER RELAYS, 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 1A, IE = SENSITIVE (MIN. = 0.001A) SURFACE MOUNTING CASE, TERMINALS ON TOP AND BOTTOM


Similar items in same category:
7SJ6311-5EB90-3FA0 L0A 7SJ6311-5EB90-3FA0 L0A MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 11BI, 8BO, WITHOUT POWER RELAYS, 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 1A, IE = 1A(MIN. = 0.05A) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) System interface Rear of the device port B PROFIBUS DP slave, RS 485 without DIGSI 4/modem interface METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>,IEP, OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) UNDERCURRENT MONITORING (37), DISPLACEMENT VOLTAGE (59N/64), BREAKER FAILURE PROTECT. (50BF) COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86) Without automatic reclosing
7SJ6311-5EB90-3FA0 L0D 7SJ6311-5EB90-3FA0 L0D MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 11BI, 8BO, WITHOUT POWER RELAYS, 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 1A, IE = 1A(MIN. = 0.05A) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) System interface Rear of the device port B MODBUS, RS 485 without DIGSI 4/modem interface METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>,IEP, OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) UNDERCURRENT MONITORING (37), DISPLACEMENT VOLTAGE (59N/64), BREAKER FAILURE PROTECT. (50BF) COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86) Without automatic reclosing
7SJ6311-5EB90-3FG1 L0S 7SJ6311-5EB90-3FG1 L0S MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 11BI, 8BO, WITHOUT POWER RELAYS, 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 1A, IE = 1A(MIN. = 0.05A) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 61850,100 MBIT ETHERNET WITH INTEGRATED SWITCH OPTICAL, DOUBLE, LC-CONNECTOR (FROM OCT. 09) WITHOUT DIGSI 4/MODEM PORT METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY: TOC+ DIRECTIONAL TOC+V/F PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PAHSE ROTATION, GROUND OVERCURRENT (50/51N): IE>, IEE>>, IEP, DIRECTIONAL TIME OVERCURRENT (67/67N WITH 50N/51N), PHASE ROTATION (47),OVERLOAD PROTECT. W.2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTECT. (50BF) COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46) LOCK OUT (86), OVER/UNDER FREQU. (81U/O), UNDER VOLTAGE (27-1,27-2),OVER VOLTAGE (59-1) WITH AUTOMATIC RECLOSING
7SJ6312-.....-.... 7SJ6312-.....-.... MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 11BI, 8BO, WITHOUT POWER RELAYS, 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 1A, IE = SENSITIVE (MIN. = 0.001A)
7SJ6312-4EB00-3FD0 7SJ6312-4EB00-3FD0 MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 11BI, 8BO, WITHOUT POWER RELAYS, 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 1A, IE = SENSITIVE (MIN. = 0.001A) SUPPLY VOLTAGE: DC 60V TO 125V, TRIGG.LEVEL BINARY INPUT DC 19V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) NO SYSTEM PORT WITHOUT DIGSI 4/MODEM PORT METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY:TOC+DIRECT. TOC+ IEE+SENSITIVE DIR. GROUND FAULT PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>, IEP, SENSITIVE DIRECTIONAL GROUND PROTECTION IEE (67N),IEE>,IEE>> GROUND VOLTAGE DISPLACEMENT(64) DIRECTIONAL TIME OVERCURRENT (67N/67N WITH 50N/51N), PHASE ROTATION (47), OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTECT. (50BF) COLD LOAD PICKUP, INRUSH BLOCKING, NEGAT.SEQUENCE(46),LOCK OUT(86) WITHOUT AUTO-RECLOSURE
7SJ6312-5EB90-3FD1 L0S 7SJ6312-5EB90-3FD1 L0S "MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19"", 11BI, 8BO, WITHOUT POWER RELAYS, 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 1A, IE = SENSITIVE (MIN. = 0.001A) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 61850,100 MBIT ETHERNET WITH INTEGRATED SWITCH OPTICAL, DOUBLE, LC-CONNECTOR (FROM OCT. 09) WITHOUT DIGSI 4/MODEM PORT METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY:TOC+DIRECT. TOC+ IEE+SENSITIVE DIR. GROUND FAULT PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>, IEP, SENSITIVE DIRECTIONAL GROUND PROTECTION IEE (67N),IEE>,IEE>> GROUND VOLTAGE DISPLACEMENT(64) DIRECTIONAL TIME OVERCURRENT (67N/67N WITH 50N/51N), PHASE ROTATION (47), OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTECT. (50BF) COLD LOAD PICKUP, INRUSH BLOCKING, NEGAT.SEQUENCE(46),LOCK OUT(86) WITH AUTOMATIC RECLOSING"
7SJ6315-.....-.... 7SJ6315-.....-.... MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 11BI, 8BO, WITHOUT POWER RELAYS, 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 5A, IE = 5A(MIN. = 0,25A)
7SJ6315-.B...-.... 7SJ6315-.B...-.... MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 11BI, 8BO, WITHOUT POWER RELAYS, 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 5A, IE = 5A(MIN. = 0,25A) SURFACE MOUNTING CASE, TERMINALS ON TOP AND BOTTOM