7SJ6021-4EB00-1HA0
Manufacturer: SIEMENS
Price: On Request
NUMERICAL OVERCURRENT-TIME PROTECT. RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS(4 X I): IN= 1A SUPPLY VOLTAGE: DC 48 TO 125V TRIGGER LEVEL BINARY INPUT 19V FLUSH MOUNTING, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISCH, GERMAN, FRENCH, SPANISH, 50/60HZ IEC/ANSI, REGION WORLD WITHOUT SYSTEM INTERFACE WITHOUT COMMAND WITH FAULT RECORDING FUNCTIONALITY: TOC+ MOTOR PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>,IEP, OVERLOAD PROTECTION WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER-FAILURE PROTECT. (50BF) COLD LOAD PICKUP, NEGATIVE SEQUENCE (46), MOTOR PROTECTION: START UP SUPERVERSION (48), UNDERCURRENT/LOSS OF LOAD MONITORING (37), RESTART INHIBIT (66/86) WITHOUT AUTOMATIC RECLOSING
Similar items in same category:
7SJ6015-6BA00-0UA0 | NUMERICAL OVERCURRENT-TIME PROTECTION RELAY SIPROTEC 7SJ601 BINARY INPUT VOLTAGE:24 TO 250V RATED CURRENT: 5A, 50/60HZ RATED AUXILIARY VOLTAGE FOR BUILT-IN CONVERTER: AC 230V IN 7XP20 CASE FOR PANEL SURFACE MOUNTING SIDE TERMINAL CONNECTION LANGUAGE: ENGLISH FREQUENCY 50HZ TRIPPING CHARACTERISTIC: DMT/IDMT I>>, I>, IE>>, IE> | |
7SJ6021-.....-.... | NUMERICAL OVERCURRENT-TIME PROTECT. RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS(4 X I): IN= 1A | |
7SJ6021-2EB20-1FA0 | NUMERICAL OVERCURRENT-TIME PROTECT. RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS(4 X I): IN= 1A SUPPLY VOLTAGE: DC 24 TO 48V TRIGGER LEVEL BINARY INPUT 19V FLUSH MOUNTING, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISCH, GERMAN, FRENCH, SPANISH, 50/60HZ IEC/ANSI, REGION WORLD SYSTEM PORT ON BOTTOM OF UNIT IEC PROTOCOL, ELECTRIC RS485 WITHOUT COMMAND WITH FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION GROUND OVERCURRENT (50N/51N) IE>, IE>>, IEP,OVERLOAD PROTEC. WITH 2 TIME CONSTANTS (49) TRIP CIRCUIT SUPERVISION (74TC) COLD LOAD PICKUP, NEGATIVE SEQUENCE (46) WITHOUT AUTOMATIC RECLOSING | |
7SJ6021-4EB00-1FA0 | NUMERICAL OVERCURRENT-TIME PROTECT. RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS(4 X I): IN= 1A SUPPLY VOLTAGE: DC 48 TO 125V TRIGGER LEVEL BINARY INPUT 19V FLUSH MOUNTING, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISCH, GERMAN, FRENCH, SPANISH, 50/60HZ IEC/ANSI, REGION WORLD WITHOUT SYSTEM INTERFACE WITHOUT COMMAND WITH FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION GROUND OVERCURRENT (50N/51N) IE>, IE>>, IEP,OVERLOAD PROTEC. WITH 2 TIME CONSTANTS (49) TRIP CIRCUIT SUPERVISION (74TC) COLD LOAD PICKUP, NEGATIVE SEQUENCE (46) WITHOUT AUTOMATIC RECLOSING | |
7SJ6021-4EB80-1HA0 | NUMERICAL OVERCURRENT-TIME PROTECT. RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS(4 X I): IN= 1A SUPPLY VOLTAGE: DC 48 TO 125V TRIGGER LEVEL BINARY INPUT 19V FLUSH MOUNTING, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISCH, GERMAN, FRENCH, SPANISH, 50/60HZ IEC/ANSI, REGION WORLD SYSTEM PORT ON BOTTOM OF UNIT THERMO-BOX, ELECTRICAL RS485 WITHOUT COMMAND WITH FAULT RECORDING FUNCTIONALITY: TOC+ MOTOR PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>,IEP, OVERLOAD PROTECTION WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER-FAILURE PROTECT. (50BF) COLD LOAD PICKUP, NEGATIVE SEQUENCE (46), MOTOR PROTECTION: START UP SUPERVERSION (48), UNDERCURRENT/LOSS OF LOAD MONITORING (37), RESTART INHIBIT (66/86) WITHOUT AUTOMATIC RECLOSING | |
7SJ6021-5EB00-1FA0 | NUMERICAL OVERCURRENT-TIME PROTECT. RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS(4 X I): IN= 1A SUPPLY VOLTAGE: DC 110 TO 250V, AC 115V, 230V TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISCH, GERMAN, FRENCH, SPANISH, 50/60HZ IEC/ANSI, REGION WORLD WITHOUT SYSTEM INTERFACE WITHOUT COMMAND WITH FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION GROUND OVERCURRENT (50N/51N) IE>, IE>>, IEP,OVERLOAD PROTEC. WITH 2 TIME CONSTANTS (49) TRIP CIRCUIT SUPERVISION (74TC) COLD LOAD PICKUP, NEGATIVE SEQUENCE (46) WITHOUT AUTOMATIC RECLOSING | |
7SJ6021-5EB00-1HA0 | NUMERICAL OVERCURRENT-TIME PROTECT. RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS(4 X I): IN= 1A SUPPLY VOLTAGE: DC 110 TO 250V, AC 115V, 230V TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISCH, GERMAN, FRENCH, SPANISH, 50/60HZ IEC/ANSI, REGION WORLD WITHOUT SYSTEM INTERFACE WITHOUT COMMAND WITH FAULT RECORDING FUNCTIONALITY: TOC+ MOTOR PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>,IEP, OVERLOAD PROTECTION WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER-FAILURE PROTECT. (50BF) COLD LOAD PICKUP, NEGATIVE SEQUENCE (46), MOTOR PROTECTION: START UP SUPERVERSION (48), UNDERCURRENT/LOSS OF LOAD MONITORING (37), RESTART INHIBIT (66/86) WITHOUT AUTOMATIC RECLOSING | |
7SJ6021-5EB10-1FA0 | NUMERICAL OVERCURRENT-TIME PROTECT. RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS(4 X I): IN= 1A SUPPLY VOLTAGE: DC 110 TO 250V, AC 115V, 230V TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISCH, GERMAN, FRENCH, SPANISH, 50/60HZ IEC/ANSI, REGION WORLD SYSTEM PORT ON BOTTOM OF UNIT IEC PROTOCOL, ELECTRIC RS232 WITHOUT COMMAND WITH FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION GROUND OVERCURRENT (50N/51N) IE>, IE>>, IEP,OVERLOAD PROTEC. WITH 2 TIME CONSTANTS (49) TRIP CIRCUIT SUPERVISION (74TC) COLD LOAD PICKUP, NEGATIVE SEQUENCE (46) WITHOUT AUTOMATIC RECLOSING |