7SD807.-.....-....

7SD807.-.....-....

Manufacturer: SIEMENS

Price: On Request

Line differential protection Enclosure 1/6 19", 4 x I, 3 x U 5 BI, 8 BQ (2 changeover contacts) 1 live contact Interface copper (2-wire connection, twisted)


Similar items in same category:
7SD8061-5EB90-1FB0 L0A 7SD8061-5EB90-1FB0 L0A Line differential protection Enclosure 1/6 19", 4 x I, 3 x U 7 BI, 8 BQ (2 changeover contacts) 1 live contact Interface FOC for mono (24 km)/multimode fiber (4 km), LC duplex plug Measuring inputs: Iph = 1 A / 5 A, Ie = 1 A / 5 A Rated auxiliary power: 60 V/ 110 V / 125 V/ 220 V/ 250 V DC 115 V / 230 V AC Installation enclosure, screw terminals Region world, IEC/ANSI English (language can be changed) Front membrane standard System interface port B (device underside, front) PROFIBUS DP slave, electr. RS 485 without further communication interface for Port A Measurement: fault recording Functionality Basic version + ??? time-overcurrent prot. Phase (I>, I>>,Ip>) and ??? ground short-circuit prot. (In>, In>>,Inp>) Without additional functions
7SD8061-5EB90-1FB0 L0D 7SD8061-5EB90-1FB0 L0D Line differential protection Enclosure 1/6 19", 4 x I, 3 x U 7 BI, 8 BQ (2 changeover contacts) 1 live contact Interface FOC for mono (24 km)/multimode fiber (4 km), LC duplex plug Measuring inputs: Iph = 1 A / 5 A, Ie = 1 A / 5 A Rated auxiliary power: 60 V/ 110 V / 125 V/ 220 V/ 250 V DC 115 V / 230 V AC Installation enclosure, screw terminals Region world, IEC/ANSI English (language can be changed) Front membrane standard System interface port B (device underside, front) Modbus, electrical RS 485 without further communication interface for Port A Measurement: fault recording Functionality Basic version + ??? time-overcurrent prot. Phase (I>, I>>,Ip>) and ??? ground short-circuit prot. (In>, In>>,Inp>) Without additional functions
7SD8061-5EB90-1FB0L0A 7SD8061-5EB90-1FB0L0A line differential protection enclosure 1/6 19", 4 x I, 3 x V, 7 BI, 8 BO (2 change-over contacts), 1 live contact, protection interface fiber-optic for mono-(24 km) / multi- mode fiber(4 km),LC duplex connector measuring inputs: Iph = 1 A/5 A, Ie = 1 A/5 A, rated auxiliary power: 60 to 250 V DC,115 V AC, 230 V AC installation enclosure, screw terminals region world, IEC / ANSI, language English (can be changed), front membrane standard, system interface port B (device underside, on front) PROFIBUS DP slave, electrical RS485 measurement: fault recording(*)
7SD8061-5EB90-1FB0L0D 7SD8061-5EB90-1FB0L0D line differential protection enclosure 1/6 19", 4 x I, 3 x V, 7 BI, 8 BO (2 change-over contacts), 1 live contact, protection interface fiber-optic for mono-(24 km) / multi- mode fiber(4 km),LC duplex connector measuring inputs: Iph = 1 A/5 A, Ie = 1 A/5 A, rated auxiliary power: 60 to 250 V DC,115 V AC, 230 V AC installation enclosure, screw terminals region world, IEC / ANSI, language English (can be changed), front membrane standard, system interface port B (device underside, on front) Modbus, electrical RS485 measurement: fault recording, functionali(*)
7SD8071-5BB20-1FA0 7SD8071-5BB20-1FA0 Line differential protection Enclosure 1/6 19", 4 x I, 3 x U 5 BI, 8 BQ (2 changeover contacts) 1 live contact Interface copper (2-wire connection, twisted) Measuring inputs: Iph = 1 A / 5 A, Ie = 1 A / 5 A Rated auxiliary power: 60 V/ 110 V / 125 V/ 220 V/ 250 V DC 115 V / 230 V AC Surface mounting enclosure screw terminals Region world, IEC/ANSI English (language can be changed) Front membrane standard System interface port B (device underside, front) IEC60870-5-103 or DIGSI4/modem or time synchronization, electrical RS 485 Without further communication interface for Port A Measurement: fault recording Functionality Line differential protection Inrush current detection Time-overcurrent protection phase I>, I>>,I>>>, Ip Time-overcurrent protection ground In>.In>>,In>>>, Inp Thermal overload protection Trip circuit monitoring Circuit breaker failure protection Closing lockout Circuit breaker intertrip External trip initiation Parameter set switchover Monitoring functions Circuit breaker test Control of circuit breaker Flexible protection functions Undervoltage/overvoltage V Underfrequency/overfrequency F Without additional functions
7SD8071-5EB20-1FA0 7SD8071-5EB20-1FA0 Line differential protection Enclosure 1/6 19", 4 x I, 3 x U 5 BI, 8 BQ (2 changeover contacts) 1 live contact Interface copper (2-wire connection, twisted) Measuring inputs: Iph = 1 A / 5 A, Ie = 1 A / 5 A Rated auxiliary power: 60 V/ 110 V / 125 V/ 220 V/ 250 V DC 115 V / 230 V AC Installation enclosure, screw terminals Region world, IEC/ANSI English (language can be changed) Front membrane standard System interface port B (device underside, front) IEC60870-5-103 or DIGSI4/modem or time synchronization, electrical RS 485 Without further communication interface for Port A Measurement: fault recording Functionality Line differential protection Inrush current detection Time-overcurrent protection phase I>, I>>,I>>>, Ip Time-overcurrent protection ground In>.In>>,In>>>, Inp Thermal overload protection Trip circuit monitoring Circuit breaker failure protection Closing lockout Circuit breaker intertrip External trip initiation Parameter set switchover Monitoring functions Circuit breaker test Control of circuit breaker Flexible protection functions Undervoltage/overvoltage V Underfrequency/overfrequency F Without additional functions
7SD8200-0XX00 7SD8200-0XX00 7SD82 Line differential protection
7SD8210-1CA20-0AA0 7SD8210-1CA20-0AA0 line differential protection, housing:surface-mounting enclosure. display:small, 24 V - 48 V DC, 11BI, 9BO, 4VT, 4xIs, 5 years guarantee, basic function points, significant feature: dual- end protection