• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.
7SD806.-.....-....

7SD806.-.....-....

Manufacturer: SIEMENS

Price: On Request

Line differential protection Enclosure 1/6 19", 4 x I, 3 x U 7 BI, 8 BQ (2 changeover contacts) 1 live contact Interface FOC for mono (24 km)/multimode fiber (4 km), LC duplex plug


Similar items in same category:
7SD8031-5EB00-1FA0 7SD8031-5EB00-1FA0 Line differential protection Enclosure 1/6 19", 4 x I, 5 BI, 8 BQ (2 changeover contacts) 1 live contact Interface copper (2-wire connection, twisted) Measuring inputs: Iph = 1 A / 5 A, Ie = 1 A / 5 A Rated auxiliary power: 60 V/ 110 V / 125 V/ 220 V/ 250 V DC 115 V / 230 V AC Installation enclosure, screw terminals Region world, IEC/ANSI English (language can be changed) Front membrane standard No system interface Without further communication interface for Port A Measurement: fault recording Functionality Line differential protection Inrush current detection Time-overcurrent protection phase I>, I>>,I>>>, Ip Time-overcurrent protection ground In>.In>>,In>>>, Inp Thermal overload protection Trip circuit monitoring Circuit breaker failure protection Closing lockout Circuit breaker intertrip External trip initiation Parameter set switchover Monitoring functions Circuit breaker test Control of circuit breaker Flexible protection functions Undervoltage/overvoltage V Underfrequency/overfrequency F Without additional functions
7SD8031-5EB07-1FA1 7SD8031-5EB07-1FA1 LINE-DIFFERENTIAL PROT. RELAY HOUSING 1/6 19", 4 X I, 5 BI, 8 BO, (2 CHANGEOVER/FORM C) 1 LIVE STATUS CONTACT PROTECTION DATA INTERFACE 2 WIRES COPPER, TWISTED MEASURING INPUTS: IPH = 1A / 5A, IE = 1A / 5A RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/ 220V/ 250V AC 115V/ 230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT NO SYSTEM PORT INTERFACE, PORT A (ON BOTTOM OF DEVICE, REAR) REDUNDANT PROTECTION DATA INTERFACE FO FOR MONO- (24 KM) AND MULTIMODE CABLE (4 KM), LC-DUPLEX CONNECTOR METERING: FAULT RECORDING FUNCTIONALITY: LINE DIFF. PROT. (87L/87NL) INRUSH-CURRENT DETECTION TIME-OVERCURRENT PROTECT. PHASE (50 TD/51), I>, I>>,I>>>, IP TIME-OVERCURRENT GROUND (50N TD/51N) IN>.IN>>,IN>>>,INP THERMAL OVERLOAD PROTECT. (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAK. FAIL.PROT.(50BF) LOCK OUT (86) INTER TRIP FUNCTION (85 DT) EXTERNAL TRIP INITIATION PARAMETER CHANGEOVER SUPERVISION FUNCTION CIRCUIT BREAKER TEST CONTROL OF CIRCUIT BREAKER FLEXIBLE PROTECTION FUNCTION: UNDER-/OVERVOLTAGE PROT.(27/59) UNDER-/OVERFREQ. PROT. (81U/O) ADDITIONAL FUNCTION: TRANSMISSION OF 16 BINARY SIGNALS VIA THE PROTECTION DATA INTERFACE
7SD8031-5EB27-1FA1 7SD8031-5EB27-1FA1 Line differential protection Enclosure 1/6 19", 4 x I, 5 BI, 8 BQ (2 changeover contacts) 1 live contact Interface copper (2-wire connection, twisted) Measuring inputs: Iph = 1 A / 5 A, Ie = 1 A / 5 A Rated auxiliary power: 60 V/ 110 V / 125 V/ 220 V/ 250 V DC 115 V / 230 V AC Installation enclosure, screw terminals Region world, IEC/ANSI English (language can be changed) Front membrane standard System interface port B (device underside, front) IEC60870-5-103 or DIGSI4/modem or time synchronization, electrical RS 485 Interface, Port A (device underside, rear) Redundant interface FOC for mono (24 km)/ multimode fiber (4 km), LC duplex plug Measurement: fault recording Functionality Line differential protection Inrush current detection Time-overcurrent protection phase I>, I>>,I>>>, Ip Time-overcurrent protection ground In>.In>>,In>>>, Inp Thermal overload protection Trip circuit monitoring Circuit breaker failure protection Closing lockout Circuit breaker intertrip External trip initiation Parameter set switchover Monitoring functions Circuit breaker test Control of circuit breaker Flexible protection functions Undervoltage/overvoltage V Underfrequency/overfrequency F Additional function: Transmission of 16 binary signals (via interface)
7SD805.-.....-.... 7SD805.-.....-.... Line differential protection Enclosure 1/6 19", 4 x I, 3 x U 3 BI, 5 BQ (2 changeover contacts) 1 live contact Interface FOC for mono (24 km)/multimode fiber (4 km), LC duplex plug
7SD8061-1EB90-1FB0 L0A 7SD8061-1EB90-1FB0 L0A Line differential protection Enclosure 1/6 19", 4 x I, 3 x U 7 BI, 8 BQ (2 changeover contacts) 1 live contact Interface FOC for mono (24 km)/multimode fiber (4 km), LC duplex plug Measuring inputs: Iph = 1 A / 5 A, Ie = 1 A / 5 A Rated auxiliary power: DC 24, 48 V Installation enclosure, screw terminals Region world, IEC/ANSI English (language can be changed) Front membrane standard System interface port B (device underside, front) PROFIBUS DP slave, electr. RS 485 without further communication interface for Port A Measurement: fault recording Functionality Basic version + ??? time-overcurrent prot. Phase (I>, I>>,Ip>) and ??? ground short-circuit prot. (In>, In>>,Inp>) Without additional functions
7SD8061-1EB90-1FB0 L0D 7SD8061-1EB90-1FB0 L0D Line differential protection Enclosure 1/6 19", 4 x I, 3 x U 7 BI, 8 BQ (2 changeover contacts) 1 live contact Interface FOC for mono (24 km)/multimode fiber (4 km), LC duplex plug Measuring inputs: Iph = 1 A / 5 A, Ie = 1 A / 5 A Rated auxiliary power: DC 24, 48 V Installation enclosure, screw terminals Region world, IEC/ANSI English (language can be changed) Front membrane standard System interface port B (device underside, front) Modbus, electrical RS 485 without further communication interface for Port A Measurement: fault recording Functionality Basic version + ??? time-overcurrent prot. Phase (I>, I>>,Ip>) and ??? ground short-circuit prot. (In>, In>>,Inp>) Without additional functions
7SD8061-1EB90-1FB0L0A 7SD8061-1EB90-1FB0L0A line differential protection enclosure 1/6 19", 4 x I, 3 x V, 7 BI, 8 BO (2 change-over contacts), 1 live contact, protection interface fiber-optic for mono-(24 km) / multi- mode fiber(4 km),LC duplex connector measuring inputs: Iph = 1 A/5 A, Ie = 1 A/5 A, rated auxiliary power: 24 - 48 V DC, installation enclosure, screw terminals region world, IEC / ANSI, language English (can be changed), front membrane standard, system interface port B (device underside, on front) PROFIBUS DP slave, electrical RS485 measurement: fault recording, functionality: ba(*)
7SD8061-1EB90-1FB0L0D 7SD8061-1EB90-1FB0L0D line differential protection enclosure 1/6 19", 4 x I, 3 x V, 7 BI, 8 BO (2 change-over contacts), 1 live contact, protection interface fiber-optic for mono-(24 km) / multi- mode fiber(4 km),LC duplex connector measuring inputs: Iph = 1 A/5 A, Ie = 1 A/5 A, rated auxiliary power: 24 - 48 V DC, installation enclosure, screw terminals region world, IEC / ANSI, language English (can be changed), front membrane standard, system interface port B (device underside, on front) Modbus, electrical RS485 measurement: fault recording, functionality: basic version(*)