• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.
7SD765.-.AA.

7SD765.-.AA.

Manufacturer: SIEMENS

Price: On Request

SOLID-STATE PILOT-WIRE DIFFERENTIAL RELAY 2 PILOT WIRES 5A, 50-60HZ


Similar items in same category:
7SD742.-.AA. 7SD742.-.AA. SOLID-STATE PILOT-WIRE DIFFERENTIAL RELAY 3 PILOT WIRES 1A, 60HZ
7SD745.-.AA. 7SD745.-.AA. SOLID-STATE PILOT-WIRE DIFFERENTIAL RELAY 3 PILOT WIRES 5A, 50HZ
7SD746.-.AA. 7SD746.-.AA. SOLID-STATE PILOT-WIRE DIFFERENTIAL RELAY 3 PILOT WIRES 5A, 60HZ
7SD761.-.AA. 7SD761.-.AA. SOLID-STATE PILOT-WIRE DIFFERENTIAL RELAY 2 PILOT WIRES 1A, 50-60HZ
7SD801.-.....-.... 7SD801.-.....-.... Line differential protection Enclosure 1/6 19", 4 x I, 3 BI, 5 BQ (2 changeover contacts) 1 live contact Interface FOC for mono (24 km)/multimode fiber (4 km), LC duplex plug
7SD8011-5EB90-3FA0 L0R 7SD8011-5EB90-3FA0 L0R LINE-DIFFERENTIAL PROT. RELAY HOUSING 1/6 19", 4 X I, 3 BI, 5 BO, (2 CHANGEOVER/FORM C) 1 LIVE STATUS CONTACT PROTECTION DATA INTERF. FO FOR MONO- (24 KM) AND MULTIMODE (4 KM), LC-DUPLEX CONNECTOR MEASURING INPUTS: IPH = 1A / 5A, IE = 1A / 5A RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/ 220V/ 250V AC 115V/ 230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, FRONT) IEC 61850, 100MBIT ETHERNET, ELECTR., DOUBLE, RJ45 CONNECTOR WITHOUT FURTHER COMMUNICATION INTERFACE AT PORT A METERING: FAULT RECORDING, AVERAGE VALUES, MIN/MAX VALUES FUNCTIONALITY: LINE DIFF. PROT. (87L/87NL) INRUSH-CURRENT DETECTION TIME-OVERCURRENT PROTECT. PHASE (50 TD/51), I>, I>>,I>>>, IP TIME-OVERCURRENT GROUND (50N TD/51N) IN>.IN>>,IN>>>,INP THERMAL OVERLOAD PROTECT. (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAK. FAIL.PROT.(50BF) LOCK OUT (86) INTER TRIP FUNCTION (85 DT) EXTERNAL TRIP INITIATION PARAMETER CHANGEOVER SUPERVISION FUNCTION CIRCUIT BREAKER TEST CONTROL OF CIRCUIT BREAKER FLEXIBLE PROTECTION FUNCTION: UNDER-/OVERVOLTAGE PROT.(27/59) UNDER-/OVERFREQ. PROT. (81U/O) WITHOUT ADDITIONAL FUNCTIONS
7SD802.-.....-.... 7SD802.-.....-.... Line differential protection Enclosure 1/6 19", 4 x I, 7 BI, 8 BQ (2 changeover contacts) 1 live contact Interface FOC for mono (24 km)/multimode fiber (4 km), LC duplex plug
7SD8021-1EB90-1FA0 L0A 7SD8021-1EB90-1FA0 L0A Line differential protection Enclosure 1/6 19", 4 x I, 7 BI, 8 BQ (2 changeover contacts) 1 live contact Interface FOC for mono (24 km)/multimode fiber (4 km), LC duplex plug Measuring inputs: Iph = 1 A / 5 A, Ie = 1 A / 5 A Rated auxiliary power: DC 24, 48 V Installation enclosure, screw terminals Region world, IEC/ANSI English (language can be changed) Front membrane standard System interface port B (device underside, front) PROFIBUS DP slave, electr. RS 485 without further communication interface for Port A Measurement: fault recording Functionality Line differential protection Inrush current detection Time-overcurrent protection phase I>, I>>,I>>>, Ip Time-overcurrent protection ground In>.In>>,In>>>, Inp Thermal overload protection Trip circuit monitoring Circuit breaker failure protection Closing lockout Circuit breaker intertrip External trip initiation Parameter set switchover Monitoring functions Circuit breaker test Control of circuit breaker Flexible protection functions Undervoltage/overvoltage V<, V> Underfrequency/overfrequency F<, F> Without additional functions