7SD523.-.....-....

7SD523.-.....-....

Manufacturer: SIEMENS

Price: On Request

MULTITERMINAL DIFFERENT. RELAY WITH 4-LINE DISPLAY FOR MULTITERMINALS (3 TO 6)


Similar items in same category:
7SD5225-6PB99-0HU6 L0R+M2H 7SD5225-6PB99-0HU6 L0R+M2H TWO TERMINAL DIFFERENT. RELAY WITH 4-LINE DISPLAY MEASUREMENT INPUT: IPH = 5A; IE = 5A AUXIL. VOLTAGE: 220V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 176V WITH 5 FAST TRIP CONTACTS, APPROX. 1MS, FLUSH-MOUNTING HOUSING WITH SCREW TERMINALS 1/1 X 19", 24 BI, 31 BO, 1 LIVE-STATUS CONTACT REGION WORLD,LANGUAGE UK-ENGL. (LANGUAGE CHANGEABLE) PORT B: SYSTEM PORT, IEC 61850,100 MBIT ETHERNET ELECTRICAL,DOUBLE, RJ45-PLUG INTERFACE ON REAR OF DEVICE DIGSI 4, ELECTRICAL RS485 PROTECTION DATA INTERFACE 1: OPTICAL 1300NM,LC-DUPLEX CONNE. FIBER LENGTH UP TO 60 KM FOR DIRECT CONNECTION VIA MONO-MODE FIBER FUNCTION 1: TRIP MODE 3-POLE ONLY, WITHOUT AUTO RECLOSURE FUNCTION WITHOUT SYNCHRONISM CHECK WITH TIME OVERCURRENT PROTECT. BREAKER FAILUR PROTECTION/ DISTANCE PROTECTION(PICKUP Z<, POLYGON,MHO,PARALLEL LINE COMP. POWER SWING DETECTION, DIRECTIONAL GROUND (EARTH)- FAULT PROTECTION WITH 4 REMOTE COMMANDS, WITH 24 REMOTE MESSAGES, WITH TRANSFORMER EXPANSIONS FAULT LOCATOR 2-SIDE MEASURING WITH RESTRICTED EARTH FAULT WITH MEASURED VALUES EXTENDED (MIN/MAX VALUES) W/O EXTERNAL GPS SYNCHRONIZAT. WITH CAPACITIVE CURRENT LOAD COMPENSATION
7SD5225-6PB99-0HU6 L0R+M2J 7SD5225-6PB99-0HU6 L0R+M2J TWO TERMINAL DIFFERENT. RELAY WITH 4-LINE DISPLAY MEASUREMENT INPUT: IPH = 5A; IE = 5A AUXIL. VOLTAGE: 220V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 176V WITH 5 FAST TRIP CONTACTS, APPROX. 1MS, FLUSH-MOUNTING HOUSING WITH SCREW TERMINALS 1/1 X 19", 24 BI, 31 BO, 1 LIVE-STATUS CONTACT REGION WORLD,LANGUAGE UK-ENGL. (LANGUAGE CHANGEABLE) PORT B: SYSTEM PORT, IEC 61850,100 MBIT ETHERNET ELECTRICAL,DOUBLE, RJ45-PLUG INTERFACE ON REAR OF DEVICE DIGSI 4, ELECTRICAL RS485 PROTECTION DATA INTERFACE 1: OPTICAL 1550NM,LC-DUPLEX CONNE. FIBER LENGTH UP TO 100 KM FOR DIRECT CONNECTION VIA MONO-MODE FIBER FUNCTION 1: TRIP MODE 3-POLE ONLY, WITHOUT AUTO RECLOSURE FUNCTION WITHOUT SYNCHRONISM CHECK WITH TIME OVERCURRENT PROTECT. BREAKER FAILUR PROTECTION/ DISTANCE PROTECTION(PICKUP Z<, POLYGON,MHO,PARALLEL LINE COMP. POWER SWING DETECTION, DIRECTIONAL GROUND (EARTH)- FAULT PROTECTION WITH 4 REMOTE COMMANDS, WITH 24 REMOTE MESSAGES, WITH TRANSFORMER EXPANSIONS FAULT LOCATOR 2-SIDE MEASURING WITH RESTRICTED EARTH FAULT WITH MEASURED VALUES EXTENDED (MIN/MAX VALUES) W/O EXTERNAL GPS SYNCHRONIZAT. WITH CAPACITIVE CURRENT LOAD COMPENSATION
7SD5226-6CB99-9HL0 L0R+M2G+N0G 7SD5226-6CB99-9HL0 L0R+M2G+N0G TWO TERMINAL DIFFERENT. RELAY WITH 4-LINE DISPLAY MEASUREMENT INPUT: IPH = 5A, IE = SENSITIVE (MIN. = 0.003A) AUXIL. VOLTAGE: 220V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 176V FLUSH-MOUNTING HOUSING WITH SCREW TERMINALS 1/1 X 19", 16 BI, 23 BO, 1 LIVE-STATUS CONTACT REGION WORLD,LANGUAGE UK-ENGL. (LANGUAGE CHANGEABLE) PORT B: SYSTEM PORT, IEC 61850,100 MBIT ETHERNET ELECTRICAL,DOUBLE, RJ45-PLUG INTERFACE ON REAR OF DEVICE DIGSI 4, ELECTRICAL RS485 PROTECTION DATA INTERFACE 1: OPTICAL 1300NM,LC-DUPLEX CONNE. FIBER LENGTH UP TO 24 KM FOR DIRECT CONNECTION VIA MONO-MODE FIBER FUNCTION 1: TRIP MODE 3-POLE ONLY, WITHOUT AUTO RECLOSURE FUNCTION WITHOUT SYNCHRONISM CHECK PROTECTION INTERFACE 2: OPTICAL 1300NM, 2 LC-DUPLEX CONNECTOR FIBER LENGTH UP TO 24 KM FOR DIRECT CONNECTION WITH MONO-MODE FIBER WITH TIME OVERCURRENT PROTECT. BREAKER FAILUR PROTECTION/ DISTANCE PROTECTION(PICKUP Z<, POLYGON,MHO,PARALLEL LINE COMP. POWER SWING DETECTION, DIRECTIONAL GROUND (EARTH)- FAULT PROTECTION WITH 4 REMOTE COMMANDS, WITH 24 REMOTE MESSAGES, WITHOUT TRANSFORMER EXTENSIONS FAULT LOCATOR 2-SIDE MEASURING W/O MEASURED VALUES EXTENDED, W/O EXTERNAL GPS-SYNCHRONIZAT. WITHOUT CAPACITIVE CURRENT LOAD COMPENSATION
7SD5226-6CB99-9HL1 L0R+M2G+N0G 7SD5226-6CB99-9HL1 L0R+M2G+N0G TWO TERMINAL DIFFERENT. RELAY WITH 4-LINE DISPLAY MEASUREMENT INPUT: IPH = 5A, IE = SENSITIVE (MIN. = 0.003A) AUXIL. VOLTAGE: 220V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 176V FLUSH-MOUNTING HOUSING WITH SCREW TERMINALS 1/1 X 19", 16 BI, 23 BO, 1 LIVE-STATUS CONTACT REGION WORLD,LANGUAGE UK-ENGL. (LANGUAGE CHANGEABLE) PORT B: SYSTEM PORT, IEC 61850,100 MBIT ETHERNET ELECTRICAL,DOUBLE, RJ45-PLUG INTERFACE ON REAR OF DEVICE DIGSI 4, ELECTRICAL RS485 PROTECTION DATA INTERFACE 1: OPTICAL 1300NM,LC-DUPLEX CONNE. FIBER LENGTH UP TO 24 KM FOR DIRECT CONNECTION VIA MONO-MODE FIBER FUNCTION 1: TRIP MODE 3-POLE ONLY, WITHOUT AUTO RECLOSURE FUNCTION WITHOUT SYNCHRONISM CHECK PROTECTION INTERFACE 2: OPTICAL 1300NM, 2 LC-DUPLEX CONNECTOR FIBER LENGTH UP TO 24 KM FOR DIRECT CONNECTION WITH MONO-MODE FIBER WITH TIME OVERCURRENT PROTECT. BREAKER FAILUR PROTECTION/ DISTANCE PROTECTION(PICKUP Z<, POLYGON,MHO,PARALLEL LINE COMP. POWER SWING DETECTION, DIRECTIONAL GROUND (EARTH)- FAULT PROTECTION WITH 4 REMOTE COMMANDS, WITH 24 REMOTE MESSAGES, WITHOUT TRANSFORMER EXTENSIONS FAULT LOCATOR 2-SIDE MEASURING W/O MEASURED VALUES, EXTENDED, WITH EXTERNAL GPS-SYNCHRONIZAT. WITHOUT CAPACITIVE CURRENT LOAD COMPENSATION
7SD5235-6CB99-9AL1 L0R+M2G+N0G 7SD5235-6CB99-9AL1 L0R+M2G+N0G MULTITERMINAL DIFFERENT. RELAY WITH 4-LINE DISPLAY FOR MULTITERMINALS (3 TO 6) MEASUREMENT INPUT: IPH = 5A; IE = 5A AUXIL. VOLTAGE: 220V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 176V FLUSH-MOUNTING HOUSING WITH SCREW TERMINALS 1/1 X 19", 16 BI, 23 BO, 1 LIVE-STATUS CONTACT REGION WORLD,LANGUAGE UK-ENGL. (LANGUAGE CHANGEABLE) PORT B: SYSTEM PORT, IEC 61850,100 MBIT ETHERNET ELECTRICAL,DOUBLE, RJ45-PLUG INTERFACE ON REAR OF DEVICE DIGSI 4, ELECTRICAL RS485 PROTECTION DATA INTERFACE 1: OPTICAL 1300NM,LC-DUPLEX CONNE. FIBER LENGTH UP TO 24 KM FOR DIRECT CONNECTION VIA MONO-MODE FIBER FUNCTION 1: TRIP MODE 3-POLE ONLY, WITHOUT AUTO RECLOSURE FUNCTION WITHOUT SYNCHRONISM CHECK PROTECTION INTERFACE 2: OPTICAL 1300NM, 2 LC-DUPLEX CONNECTOR FIBER LENGTH UP TO 24 KM FOR DIRECT CONNECTION WITH MONO-MODE FIBER WITHOUT BACKUP FUNCTIONS WITH 4 REMOTE COMMANDS, WITH 24 REMOTE MESSAGES, WITHOUT TRANSFORMER EXTENSIONS FAULT LOCATOR 2-SIDE MEASURING W/O MEASURED VALUES, EXTENDED, WITH EXTERNAL GPS-SYNCHRONIZAT. WITHOUT CAPACITIVE CURRENT LOAD COMPENSATION
7SD532.-.....-.... 7SD532.-.....-.... TWO TERMINAL DIFFERENT. RELAY WITH GRAPHICAL DISPLAY
7SD5321-4PB99-9EL6 L0S+M0A+N0A 7SD5321-4PB99-9EL6 L0S+M0A+N0A TWO TERMINAL DIFFERENT. RELAY WITH GRAPHICAL DISPLAY MEASUREMENT INPUT: IPH = 1A; IE = 1A AUXIL. VOLTAGE: 60V TO 125V DC BINARY INPUT THRESHOLD 19V WITH 5 FAST TRIP CONTACTS, APPROX. 1MS, FLUSH-MOUNTING HOUSING WITH SCREW TERMINALS 1/1 X 19", 24 BI, 31 BO, 1 LIVE-STATUS CONTACT REGION WORLD,LANGUAGE UK-ENGL. (LANGUAGE CHANGEABLE) PORT B: SYSTEM PORT, IEC 61850,100 MBIT ETHERNET WITH INTEGRATED SWITCH OPTICAL, DOUBLE, LC-CONNECTOR (FROM OCT. 09) NO DIGSI INTERFACE ON REAR OF DEVICE, PROTECTION INTERFACE 1: OPTICAL 820NM,TWO ST-CONNECTORS FO LENGTH UP TO 1,5KM, FOR MULTIMODE FIBER FOR DIRECT CONNECTION OR COMMUNICATION NETWORKS FUNCTION 1: TRIP MODE 3-POLE ONLY, WITHOUT AUTO RECLOSURE FUNCTION WITHOUT SYNCHRONISM CHECK PROTECTION INTERFACE 2: OPTICAL 820NM,TWO ST-CONNECTORS FO LENGTH UP TO 1,5KM FOR MULTIMODE FIBER FOR DIRECT CONNECTION OR COMMUNICATION NETWORKS WITH OVERCURRENT PROTECTION/ BREAKER FAILURE PROTECTION/ DISTANCE PROTECTION (PICKUP Z<, POLYGON,MHO,PARALLEL LINE COMP. POWER SWING PROTECTION WITH 4 REMOTE COMMANDS, WITH 24 REMOTE MESSAGES, WITHOUT TRANSFORMER EXTENSIONS FAULT LOCATOR 2-SIDE MEASURING WITH MEASURED VALUES EXTENDED (MIN/MAX VALUES) W/O EXTERNAL GPS SYNCHRONIZAT. WITH CAPACITIVE CURRENT LOAD COMPENSATION
7SD533.-.....-.... 7SD533.-.....-.... MULTITERMINAL DIFFERENT. RELAY WITH GRAPHICAL DISPLAY FOR MULTITERMINALS (3 TO 6)