7SA5225-6DA02-0QP4

7SA5225-6DA02-0QP4

Manufacturer: SIEMENS

Price: On Request

FULL SCHEME DISTANCE PROTECTION RELAY, CURRENT TRANSFORMER:PHASE = 5A, GROUND(EARTH)= 5A (MIN=0,25A) FLUSH-MOUNTG. HOUSING 1/1 X 19" 24 BI, 32 BO AUXIL. VOLTAGE:220V TO 250V DC, 115V AC, BINARY INPUT THRESHOLD 176V REGION DE, LANGUAGE GERMAN (LANGUAGE SELECTABLE) WITHOUT SYSTEM INTERFACE DIGSI/MODEM OPERATING INTERFACE (ON REAR OF DEVICE) DIGSI 4, ELECTRICAL RS485 FUNCTION 1: TRIP MODE 3POLE FUNCTION 2: DISTANCE CHARACTERISTIC Z<, QUADRILATERAL AND/OR MHO WITH POWER SWING WITH PARALLEL LINE COMPENSATION FUNCTION 3: WITH AUTORECLOSURE WITH SYNCHROCHECK W/O BREAKER FAILURE PROTECTION WITH OVERVOLTAGE PROTECTION FUNCTION 4: WITH GROUND FAULT OVERCURRENT PROTECTION


Similar items in same category:
7SA5225-5DB00-4EK0 7SA5225-5DB00-4EK0 FULL SCHEME DISTANCE PROTECTION RELAY, CURRENT TRANSFORMER:PHASE = 5A, GROUND(EARTH)= 5A (MIN=0,25A) FLUSH-MOUNTG. HOUSING 1/1 X 19" 24 BI, 32 BO AUXIL. VOLTAGE: 110V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 88V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) WITHOUT SYSTEM INTERFACE NO 2ND OPERATING INTERFACE FUNCTION 1: TRIP MODE 1- AND 3-POLE FUNCTION 2: DISTANCE CHARACTERISTIC Z<, QUADRILATERAL AND/OR MHO WITHOUT POWER SWING W/O PRALLEL LINE COMPENSATION FUNCTION 3: WITH AUTORECLOSURE WITHOUT SYNCHROCHECK W/O BREAKER FAILURE PROTECTION WITH OVERVOLTAGE PROTECTION FUNCTION 4: WITHOUT GROUND FAULT OVERCURR. PROTECTION
7SA5225-5DB20-4NM4 7SA5225-5DB20-4NM4 FULL SCHEME DISTANCE PROTECTION RELAY, CURRENT TRANSFORMER:PHASE = 5A, GROUND(EARTH)= 5A (MIN=0,25A) FLUSH-MOUNTG. HOUSING 1/1 X 19" 24 BI, 32 BO AUXIL. VOLTAGE: 110V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 88V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) SYSTEM INTERFACE: IEC 60870-5-103,ELECTRIC. RS485 NO 2ND OPERATING INTERFACE FUNCTION 1: TRIP MODE 1- AND 3-POLE FUNCTION 2: DISTANCE CHARACTERISTIC Z<, QUADRILATERAL, WITH POWER SWING WITH PARALLEL LINE COMPENSATION FUNCTION 3: WITH AUTORECLOSURE WITHOUT SYNCHROCHECK WITH BREAKER FAILURE PROTECTION WITH OVERVOLTAGE PROTECTION FUNCTION 4: WITH GROUND FAULT OVERCURRENT PROTECTION
7SA5225-6AB92-1HA4 L0R 7SA5225-6AB92-1HA4 L0R FULL SCHEME DISTANCE PROTECTION RELAY, CURRENT TRANSFORMER:PHASE = 5A, GROUND(EARTH)= 5A (MIN=0,25A) FLUSH-MOUNTG. HOUSING 1/2 X 19" 8 BI, 16 BO AUXIL. VOLTAGE:220V TO 250V DC, 115V AC, BINARY INPUT THRESHOLD 176V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) PORT P: SYSTEM PORT, IEC 61850,100 MBIT ETHERNET ELECTRICAL,DOUBLE,RJ45-PLUG DIGSI/MODEM OPERATING INTERFACE (ON REAR OF DEVICE) DIGSI 4, ELECTRICAL RS485 FUNCTION 1: TRIP MODE 3POLE, BCD-CODED OUTPUT FOR FAULT LOCATION FUNCTION 2: DISTANCE CHARACTERISTIC Z<, QUADRILATERAL AND/OR MHO WITH POWER SWING W/O PARALLEL LINE COMPENSATION FUNCTION 3: WITHOUT AUTORECLOSURE WITHOUT SYNCHROCHECK W/O BREAKER FAILURE PROTECTION WITHOUT OVERVOLTAGE PROTECTION FUNCTION 4: WITH GROUND FAULT OVERCURRENT PROTECTION
7SA5225-6CB92-0FA4 L0R 7SA5225-6CB92-0FA4 L0R FULL SCHEME DISTANCE PROTECTION RELAY, CURRENT TRANSFORMER:PHASE = 5A, GROUND(EARTH)= 5A (MIN=0,25A) FLUSH-MOUNTG. HOUSING 1/1 X 19" 16 BI, 24 BO AUXIL. VOLTAGE:220V TO 250V DC, 115V AC, BINARY INPUT THRESHOLD 176V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) PORT P: SYSTEM PORT, IEC 61850,100 MBIT ETHERNET ELECTRICAL,DOUBLE,RJ45-PLUG DIGSI/MODEM OPERATING INTERFACE (ON REAR OF DEVICE) DIGSI 4, ELECTRICAL RS485 FUNCTION 1: TRIP MODE 3POLE FUNCTION 2: DISTANCE CHARACTERISTIC Z<, QUADRILATERAL, WITH POWER SWING W/O PARALLEL LINE COMPENSATION FUNCTION 3: WITHOUT AUTORECLOSURE WITHOUT SYNCHROCHECK W/O BREAKER FAILURE PROTECTION WITHOUT OVERVOLTAGE PROTECTION FUNCTION 4: WITH GROUND FAULT OVERCURRENT PROTECTION
7SA5225-6DB02-0QP4 7SA5225-6DB02-0QP4 FULL SCHEME DISTANCE PROTECTION RELAY, CURRENT TRANSFORMER:PHASE = 5A, GROUND(EARTH)= 5A (MIN=0,25A) FLUSH-MOUNTG. HOUSING 1/1 X 19" 24 BI, 32 BO AUXIL. VOLTAGE:220V TO 250V DC, 115V AC, BINARY INPUT THRESHOLD 176V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) WITHOUT SYSTEM INTERFACE DIGSI/MODEM OPERATING INTERFACE (ON REAR OF DEVICE) DIGSI 4, ELECTRICAL RS485 FUNCTION 1: TRIP MODE 3POLE FUNCTION 2: DISTANCE CHARACTERISTIC Z<, QUADRILATERAL AND/OR MHO WITH POWER SWING WITH PARALLEL LINE COMPENSATION FUNCTION 3: WITH AUTORECLOSURE WITH SYNCHROCHECK W/O BREAKER FAILURE PROTECTION WITH OVERVOLTAGE PROTECTION FUNCTION 4: WITH GROUND FAULT OVERCURRENT PROTECTION
7SA5225-6DB92-0NB5 L0R 7SA5225-6DB92-0NB5 L0R FULL SCHEME DISTANCE PROTECTION RELAY, CURRENT TRANSFORMER:PHASE = 5A, GROUND(EARTH)= 5A (MIN=0,25A) FLUSH-MOUNTG. HOUSING 1/1 X 19" 24 BI, 32 BO AUXIL. VOLTAGE:220V TO 250V DC, 115V AC, BINARY INPUT THRESHOLD 176V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) PORT P: SYSTEM PORT, IEC 61850,100 MBIT ETHERNET ELECTRICAL,DOUBLE,RJ45-PLUG DIGSI/MODEM OPERATING INTERFACE (ON REAR OF DEVICE) DIGSI 4, ELECTRICAL RS485 FUNCTION 1: TRIP MODE 3POLE FUNCTION 2: DISTANCE CHARACTERISTIC Z<, QUADRILATERAL, WITH POWER SWING WITH PARALLEL LINE COMPENSATION FUNCTION 3: WITHOUT AUTORECLOSURE WITHOUT SYNCHROCHECK W/O BREAKER FAILURE PROTECTION WITH OVERVOLTAGE PROTECTION FUNCTION 4: EARTH-FAULT PROT. DIRECTIONAL, EARTHED NETWORKS MEASURED VALUES EXTENDE (MIN., MAX,. MEAN)
7SA5225-6DB92-1NB4 L0R 7SA5225-6DB92-1NB4 L0R FULL SCHEME DISTANCE PROTECTION RELAY, CURRENT TRANSFORMER:PHASE = 5A, GROUND(EARTH)= 5A (MIN=0,25A) FLUSH-MOUNTG. HOUSING 1/1 X 19" 24 BI, 32 BO AUXIL. VOLTAGE:220V TO 250V DC, 115V AC, BINARY INPUT THRESHOLD 176V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) PORT P: SYSTEM PORT, IEC 61850,100 MBIT ETHERNET ELECTRICAL,DOUBLE,RJ45-PLUG DIGSI/MODEM OPERATING INTERFACE (ON REAR OF DEVICE) DIGSI 4, ELECTRICAL RS485 FUNCTION 1: TRIP MODE 3POLE, BCD-CODED OUTPUT FOR FAULT LOCATION FUNCTION 2: DISTANCE CHARACTERISTIC Z<, QUADRILATERAL, WITH POWER SWING WITH PARALLEL LINE COMPENSATION FUNCTION 3: WITHOUT AUTORECLOSURE WITHOUT SYNCHROCHECK W/O BREAKER FAILURE PROTECTION WITH OVERVOLTAGE PROTECTION FUNCTION 4: WITH GROUND FAULT OVERCURRENT PROTECTION
7SA5225-6DB92-1NB5 L0R 7SA5225-6DB92-1NB5 L0R FULL SCHEME DISTANCE PROTECTION RELAY, CURRENT TRANSFORMER:PHASE = 5A, GROUND(EARTH)= 5A (MIN=0,25A) FLUSH-MOUNTG. HOUSING 1/1 X 19" 24 BI, 32 BO AUXIL. VOLTAGE:220V TO 250V DC, 115V AC, BINARY INPUT THRESHOLD 176V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) PORT P: SYSTEM PORT, IEC 61850,100 MBIT ETHERNET ELECTRICAL,DOUBLE,RJ45-PLUG DIGSI/MODEM OPERATING INTERFACE (ON REAR OF DEVICE) DIGSI 4, ELECTRICAL RS485 FUNCTION 1: TRIP MODE 3POLE, BCD-CODED OUTPUT FOR FAULT LOCATION FUNCTION 2: DISTANCE CHARACTERISTIC Z<, QUADRILATERAL, WITH POWER SWING WITH PARALLEL LINE COMPENSATION FUNCTION 3: WITHOUT AUTORECLOSURE WITHOUT SYNCHROCHECK W/O BREAKER FAILURE PROTECTION WITH OVERVOLTAGE PROTECTION FUNCTION 4: EARTH-FAULT PROT. DIRECTIONAL, EARTHED NETWORKS MEASURED VALUES EXTENDE (MIN., MAX,. MEAN)