• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.
7SA5225-4AB10-4QR4

7SA5225-4AB10-4QR4

Manufacturer: SIEMENS

Price: On Request

FULL SCHEME DISTANCE PROTECTION RELAY, CURRENT TRANSFORMER:PHASE = 5A, GROUND(EARTH)= 5A (MIN=0,25A) FLUSH-MOUNTG. HOUSING 1/2 X 19" 8 BI, 16 BO AUXIL. VOLTAGE: 60V TO 125V DC BINARY INPUT THRESHOLD 19V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) SYSTEM INTERFACE: IEC 60870-5-103,ELECTRIC. RS232 NO 2ND OPERATING INTERFACE FUNCTION 1: TRIP MODE 1- AND 3-POLE FUNCTION 2: DISTANCE CHARACTERISTIC Z<, QUADRILATERAL AND/OR MHO WITH POWER SWING WITH PARALLEL LINE COMPENSATION FUNCTION 3: WITH AUTORECLOSURE WITH SYNCHROCHECK WITH BREAKER FAILURE PROTECTION WITH OVERVOLTAGE PROTECTION FUNCTION 4: WITH GROUND FAULT OVERCURRENT PROTECTION


Similar items in same category:
7SA5225-.S...-.... 7SA5225-.S...-.... FULL SCHEME DISTANCE PROTECTION RELAY, CURRENT TRANSFORMER:PHASE = 5A, GROUND(EARTH)= 5A (MIN=0,25A) FLUSH-MOUNTING HOUSING WITH PLUG-IN TERMINALS 1/1 X 19", 16 BI, 16 BO, 3 FAST RELAYS, 5 HIGH-SPEED TRIP OUTPUTS
7SA5225-.T...-.... 7SA5225-.T...-.... FULL SCHEME DISTANCE PROTECTION RELAY, CURRENT TRANSFORMER:PHASE = 5A, GROUND(EARTH)= 5A (MIN=0,25A) FLUSH-MOUNTING HOUSING WITH PLUG-IN TERMINALS 1/1 X 19", 24 BI, 24 BO, 3 FAST RELAYS 5 HIGH-SPEED TRIP OUTPUTS
7SA5225-.U...-.... 7SA5225-.U...-.... FULL SCHEME DISTANCE PROTECTION RELAY, CURRENT TRANSFORMER:PHASE = 5A, GROUND(EARTH)= 5A (MIN=0,25A) FLUSH-MOUNTG. HOUSING 1/1 X 19" 22 BI, 37 BO, 7 FAST RELAYS
7SA5225-.W...-.... 7SA5225-.W...-.... FULL SCHEME DISTANCE PROTECTION RELAY, CURRENT TRANSFORMER:PHASE = 5A, GROUND(EARTH)= 5A (MIN=0,25A) FLUSH-MOUNTG. HOUSING 1/1 X 19" 24 BI, 4 BO, 18 FAST RELAYS, 10 HIGH-SPEED TRIP OUTPUTS
7SA5225-4DB22-4QR5 7SA5225-4DB22-4QR5 FULL SCHEME DISTANCE PROTECTION RELAY, CURRENT TRANSFORMER:PHASE = 5A, GROUND(EARTH)= 5A (MIN=0,25A) FLUSH-MOUNTG. HOUSING 1/1 X 19" 24 BI, 32 BO AUXIL. VOLTAGE: 60V TO 125V DC BINARY INPUT THRESHOLD 19V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) SYSTEM INTERFACE: IEC 60870-5-103,ELECTRIC. RS485 DIGSI/MODEM OPERATING INTERFACE (ON REAR OF DEVICE) DIGSI 4, ELECTRICAL RS485 FUNCTION 1: TRIP MODE 1- AND 3-POLE FUNCTION 2: DISTANCE CHARACTERISTIC Z<, QUADRILATERAL AND/OR MHO WITH POWER SWING WITH PARALLEL LINE COMPENSATION FUNCTION 3: WITH AUTORECLOSURE WITH SYNCHROCHECK WITH BREAKER FAILURE PROTECTION WITH OVERVOLTAGE PROTECTION FUNCTION 4: EARTH-FAULT PROT. DIRECTIONAL, EARTHED NETWORKS MEASURED VALUES EXTENDE (MIN., MAX,. MEAN)
7SA5225-5AB11-0HP0 7SA5225-5AB11-0HP0 FULL SCHEME DISTANCE PROTECTION RELAY, CURRENT TRANSFORMER:PHASE = 5A, GROUND(EARTH)= 5A (MIN=0,25A) FLUSH-MOUNTG. HOUSING 1/2 X 19" 8 BI, 16 BO AUXIL. VOLTAGE: 110V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 88V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) SYSTEM INTERFACE: IEC 60870-5-103,ELECTRIC. RS232 DIGSI/MODEM OPERATING INTERFACE (ON REAR OF DEVICE) DIGSI 4, ELECTRICAL RS232 FUNCTION 1: TRIP MODE 3POLE FUNCTION 2: DISTANCE CHARACTERISTIC Z<, QUADRILATERAL AND/OR MHO WITH POWER SWING W/O PARALLEL LINE COMPENSATION FUNCTION 3: WITH AUTORECLOSURE WITH SYNCHROCHECK W/O BREAKER FAILURE PROTECTION WITH OVERVOLTAGE PROTECTION FUNCTION 4: WITHOUT GROUND FAULT OVERCURR. PROTECTION
7SA5225-5CB12-4QR4 7SA5225-5CB12-4QR4 FULL SCHEME DISTANCE PROTECTION RELAY, CURRENT TRANSFORMER:PHASE = 5A, GROUND(EARTH)= 5A (MIN=0,25A) FLUSH-MOUNTG. HOUSING 1/1 X 19" 16 BI, 24 BO AUXIL. VOLTAGE: 110V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 88V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) SYSTEM INTERFACE: IEC 60870-5-103,ELECTRIC. RS232 DIGSI/MODEM OPERATING INTERFACE (ON REAR OF DEVICE) DIGSI 4, ELECTRICAL RS485 FUNCTION 1: TRIP MODE 1- AND 3-POLE FUNCTION 2: DISTANCE CHARACTERISTIC Z<, QUADRILATERAL AND/OR MHO WITH POWER SWING WITH PARALLEL LINE COMPENSATION FUNCTION 3: WITH AUTORECLOSURE WITH SYNCHROCHECK WITH BREAKER FAILURE PROTECTION WITH OVERVOLTAGE PROTECTION FUNCTION 4: WITH GROUND FAULT OVERCURRENT PROTECTION
7SA5225-5DB00-4EK0 7SA5225-5DB00-4EK0 FULL SCHEME DISTANCE PROTECTION RELAY, CURRENT TRANSFORMER:PHASE = 5A, GROUND(EARTH)= 5A (MIN=0,25A) FLUSH-MOUNTG. HOUSING 1/1 X 19" 24 BI, 32 BO AUXIL. VOLTAGE: 110V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 88V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) WITHOUT SYSTEM INTERFACE NO 2ND OPERATING INTERFACE FUNCTION 1: TRIP MODE 1- AND 3-POLE FUNCTION 2: DISTANCE CHARACTERISTIC Z<, QUADRILATERAL AND/OR MHO WITHOUT POWER SWING W/O PRALLEL LINE COMPENSATION FUNCTION 3: WITH AUTORECLOSURE WITHOUT SYNCHROCHECK W/O BREAKER FAILURE PROTECTION WITH OVERVOLTAGE PROTECTION FUNCTION 4: WITHOUT GROUND FAULT OVERCURR. PROTECTION