7SA5221-4DB22-0QJ4
Manufacturer: SIEMENS
Price: On Request
FULL SCHEME DISTANCE PROTECTION
RELAY,
CURRENT TRANSFORMER:
PHASE=1A,GROUND=1A (MIN=0,05A)
FLUSH-MOUNTG. HOUSING 1/1 X 19"
24 BI, 32 BO
AUXIL. VOLTAGE: 60V TO 125V DC
BINARY INPUT THRESHOLD 19V
REGION WORLD,LANGUA. UK-ENGLISH
(LANGUAGE SELECTABLE)
SYSTEM INTERFACE:
IEC 60870-5-103,ELECTRIC. RS485
DIGSI/MODEM OPERATING INTERFACE
(ON REAR OF DEVICE)
DIGSI 4, ELECTRICAL RS485
FUNCTION 1: TRIP MODE 3POLE
FUNCTION 2:
DISTANCE CHARACTERISTIC Z<,
QUADRILATERAL AND/OR MHO
WITH POWER SWING
WITH PARALLEL LINE COMPENSATION
FUNCTION 3:
WITH AUTORECLOSURE
WITHOUT SYNCHROCHECK
W/O BREAKER FAILURE PROTECTION
WITHOUT OVERVOLTAGE PROTECTION
FUNCTION 4:
WITH GROUND FAULT OVERCURRENT
PROTECTION
Similar items in same category:
7SA5221-.W...-.... | FULL SCHEME DISTANCE PROTECTION RELAY, CURRENT TRANSFORMER: PHASE=1A,GROUND=1A (MIN=0,05A) FLUSH-MOUNTG. HOUSING 1/1 X 19" 24 BI, 4 BO, 18 FAST RELAYS, 10 HIGH-SPEED TRIP OUTPUTS | |
7SA5221-4AB20-0HA0 | FULL SCHEME DISTANCE PROTECTION RELAY, CURRENT TRANSFORMER: PHASE=1A,GROUND=1A (MIN=0,05A) FLUSH-MOUNTG. HOUSING 1/2 X 19" 8 BI, 16 BO AUXIL. VOLTAGE: 60V TO 125V DC BINARY INPUT THRESHOLD 19V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) SYSTEM INTERFACE: IEC 60870-5-103,ELECTRIC. RS485 NO 2ND OPERATING INTERFACE FUNCTION 1: TRIP MODE 3POLE FUNCTION 2: DISTANCE CHARACTERISTIC Z<, QUADRILATERAL AND/OR MHO WITH POWER SWING W/O PARALLEL LINE COMPENSATION FUNCTION 3: WITHOUT AUTORECLOSURE WITHOUT SYNCHROCHECK W/O BREAKER FAILURE PROTECTION WITHOUT OVERVOLTAGE PROTECTION FUNCTION 4: WITHOUT GROUND FAULT OVERCURR. PROTECTION | |
7SA5221-4CB00-0QA0 | FULL SCHEME DISTANCE PROTECTION RELAY, CURRENT TRANSFORMER: PHASE=1A,GROUND=1A (MIN=0,05A) FLUSH-MOUNTG. HOUSING 1/1 X 19" 16 BI, 24 BO AUXIL. VOLTAGE: 60V TO 125V DC BINARY INPUT THRESHOLD 19V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) WITHOUT SYSTEM INTERFACE NO 2ND OPERATING INTERFACE FUNCTION 1: TRIP MODE 3POLE FUNCTION 2: DISTANCE CHARACTERISTIC Z<, QUADRILATERAL AND/OR MHO WITH POWER SWING WITH PARALLEL LINE COMPENSATION FUNCTION 3: WITHOUT AUTORECLOSURE WITHOUT SYNCHROCHECK W/O BREAKER FAILURE PROTECTION WITHOUT OVERVOLTAGE PROTECTION FUNCTION 4: WITHOUT GROUND FAULT OVERCURR. PROTECTION | |
7SA5221-4DB00-4HP4 | "FULL SCHEME DISTANCE PROTECTION RELAY, CURRENT TRANSFORMER: PHASE=1A,GROUND=1A (MIN=0,05A) FLUSH-MOUNTG. HOUSING 1/1 X 19"" 24 BI, 32 BO AUXIL. VOLTAGE: 60V TO 125V DC BINARY INPUT THRESHOLD 19V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) WITHOUT SYSTEM INTERFACE NO 2ND OPERATING INTERFACE FUNCTION 1: TRIP MODE 1- AND 3-POLE FUNCTION 2: DISTANCE CHARACTERISTIC Z<, QUADRILATERAL AND/OR MHO WITH POWER SWING W/O PARALLEL LINE COMPENSATION FUNCTION 3: WITH AUTORECLOSURE WITH SYNCHROCHECK W/O BREAKER FAILURE PROTECTION WITH OVERVOLTAGE PROTECTION FUNCTION 4: WITH GROUND FAULT OVERCURRENT PROTECTION" | |
7SA5221-4DB90-4QQ4 L0S | FULL SCHEME DISTANCE PROTECTION RELAY, CURRENT TRANSFORMER: PHASE=1A,GROUND=1A (MIN=0,05A) FLUSH-MOUNTG. HOUSING 1/1 X 19" 24 BI, 32 BO AUXIL. VOLTAGE: 60V TO 125V DC BINARY INPUT THRESHOLD 19V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) PORT B: SYSTEM PORT, IEC 61850,100 MBIT ETHERNET WITH INTEGRATED SWITCH OPTICAL,DOUBLE, LC-CONNECTOR (FROM OCT. 09) NO 2ND OPERATING INTERFACE FUNCTION 1: TRIP MODE 1- AND 3-POLE FUNCTION 2: DISTANCE CHARACTERISTIC Z<, QUADRILATERAL AND/OR MHO WITH POWER SWING WITH PARALLEL LINE COMPENSATION FUNCTION 3: WITH AUTORECLOSURE WITH SYNCHROCHECK WITH BREAKER FAILURE PROTECTION WITHOUT OVERVOLTAGE PROTECTION FUNCTION 4: WITH GROUND FAULT OVERCURRENT PROTECTION | |
7SA5221-4DB90-5QB5 L0S | FULL SCHEME DISTANCE PROTECTION RELAY, CURRENT TRANSFORMER: PHASE=1A,GROUND=1A (MIN=0,05A) FLUSH-MOUNTG. HOUSING 1/1 X 19" 24 BI, 32 BO AUXIL. VOLTAGE: 60V TO 125V DC BINARY INPUT THRESHOLD 19V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) PORT B: SYSTEM PORT, IEC 61850,100 MBIT ETHERNET WITH INTEGRATED SWITCH OPTICAL,DOUBLE, LC-CONNECTOR (FROM OCT. 09) NO 2ND OPERATING INTERFACE FUNCTION 1: TRIP MODE 1- AND 3-POLE, BCD-CODED OUTPUT FOR FAULT LOCATION, FUNCTION 2: DISTANCE CHARACTERISTIC Z<, QUADRILATERAL AND/OR MHO WITH POWER SWING WITH PARALLEL LINE COMPENSATION FUNCTION 3: WITHOUT AUTORECLOSURE WITHOUT SYNCHROCHECK W/O BREAKER FAILURE PROTECTION WITH OVERVOLTAGE PROTECTION FUNCTION 4: EARTH-FAULT PROT. DIRECTIONAL, EARTHED NETWORKS MEASURED VALUES EXTENDE (MIN., MAX,. MEAN) | |
7SA5221-4DB90-5QP4 L0S | FULL SCHEME DISTANCE PROTECTION RELAY, CURRENT TRANSFORMER: PHASE=1A,GROUND=1A (MIN=0,05A) FLUSH-MOUNTG. HOUSING 1/1 X 19" 24 BI, 32 BO AUXIL. VOLTAGE: 60V TO 125V DC BINARY INPUT THRESHOLD 19V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) PORT B: SYSTEM PORT, IEC 61850,100 MBIT ETHERNET WITH INTEGRATED SWITCH OPTICAL,DOUBLE, LC-CONNECTOR (FROM OCT. 09) NO 2ND OPERATING INTERFACE FUNCTION 1: TRIP MODE 1- AND 3-POLE, BCD-CODED OUTPUT FOR FAULT LOCATION, FUNCTION 2: DISTANCE CHARACTERISTIC Z<, QUADRILATERAL AND/OR MHO WITH POWER SWING WITH PARALLEL LINE COMPENSATION FUNCTION 3: WITH AUTORECLOSURE WITH SYNCHROCHECK W/O BREAKER FAILURE PROTECTION WITH OVERVOLTAGE PROTECTION FUNCTION 4: WITH GROUND FAULT OVERCURRENT PROTECTION | |
7SA5221-4DB92-4QB4 L0S | FULL SCHEME DISTANCE PROTECTION RELAY, CURRENT TRANSFORMER: PHASE=1A,GROUND=1A (MIN=0,05A) FLUSH-MOUNTG. HOUSING 1/1 X 19" 24 BI, 32 BO AUXIL. VOLTAGE: 60V TO 125V DC BINARY INPUT THRESHOLD 19V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) PORT B: SYSTEM PORT, IEC 61850,100 MBIT ETHERNET WITH INTEGRATED SWITCH OPTICAL,DOUBLE, LC-CONNECTOR (FROM OCT. 09) DIGSI/MODEM OPERATING INTERFACE (ON REAR OF DEVICE) DIGSI 4, ELECTRICAL RS485 FUNCTION 1: TRIP MODE 1- AND 3-POLE FUNCTION 2: DISTANCE CHARACTERISTIC Z<, QUADRILATERAL AND/OR MHO WITH POWER SWING WITH PARALLEL LINE COMPENSATION FUNCTION 3: WITHOUT AUTORECLOSURE WITHOUT SYNCHROCHECK W/O BREAKER FAILURE PROTECTION WITH OVERVOLTAGE PROTECTION FUNCTION 4: WITH GROUND FAULT OVERCURRENT PROTECTION |