7RW8010-5EB00-1DA0
Manufacturer: SIEMENS
Price: On Request
Voltage and frequency relay Enclosure 1/6 19", 3 x V, 3 BI, 5 BO, (2 change-over contacts), 1 live contact . Auxiliary voltage: 60/110/125/220/250 V DC, 115 V AC, 230 V AC Installation encl., Screw terminals Region world, IEC/ANSI Language English (language can be changed) Front foil standard no system interface without system interface, Port A Measurement: with fault recording and min./max. values of voltages Functionality: Voltage and frequency protection Undervoltage/overvoltage (27/59) Displacement voltage (64/59N), Under/overfrequency (81U/O) Rotary field direction (47) Trip circuit supervision (74TC), Lock out (86), Change setting groups, Monitoring functions, Control of circuit breaker, Flexible protection functions (parameters from voltage), Frequency change / voltage change protection .
Similar items in same category:
7RW8010-1EB90-1DC0L0A | voltage and frequency relay, enclosure 1/6 19", 3 x V, 3 BI, 5 BO (2 change-over contacts), 1 live contact, rated auxiliary power: 24 - 48 V DC, installation enclosure, screw terminals region world, IEC / ANSI, language English (can be changed), front membrane standard, system interface port B (device underside, rear) PROFIBUS DP slave, electrical RS485 without system interface, port A measurement: fault recording,, mean value formation, min./max. values, functionality: voltage and frequency protection and synchro check | |
7RW8010-1EB90-1DC0L0D | voltage and frequency relay, enclosure 1/6 19", 3 x V, 3 BI, 5 BO (2 change-over contacts), 1 live contact, rated auxiliary power: 24 - 48 V DC, installation enclosure, screw terminals region world, IEC / ANSI, language English (can be changed), front membrane standard, system interface port B (device underside, rear) Modbus, electrical RS485 without system interface, port A measurement: fault recording, mean value formation, min./max. values, functionality: voltage and frequency protection and synchro check | |
7RW8010-5BB00-1DA0 | Voltage and frequency relay Enclosure 1/6 19", 3 x V, 3 BI, 5 BO, (2 change-over contacts), 1 live contact . Auxiliary voltage: 60/110/125/220/250 V DC, 115 V AC, 230 V AC Mounted enclosure, Screw terminals Region world, IEC/ANSI Language English (language can be changed) Front foil standard no system interface without system interface, Port A Measurement: with fault recording and min./max. values of voltages Functionality: Voltage and frequency protection Undervoltage/overvoltage (27/59) Displacement voltage (64/59N), Under/overfrequency (81U/O) Rotary field direction (47) Trip circuit supervision (74TC), Lock out (86), Change setting groups, Monitoring functions, Control of circuit breaker, Flexible protection functions (parameters from voltage), Frequency change / voltage change protection . | |
7RW8010-5EA00-1DA0 | Voltage and frequency relay Enclosure 1/6 19", 3 x V, 3 BI, 5 BO, (2 change-over contacts), 1 live contact . Auxiliary voltage: 60/110/125/220/250 V DC, 115 V AC, 230 V AC Installation encl., Screw terminals Region DE, IEC, Language German (language can be changed) Front foil standard no system interface without system interface, Port A Measurement: with fault recording and min./max. values of voltages Functionality: Voltage and frequency protection Undervoltage/overvoltage (27/59) Displacement voltage (64/59N), Under/overfrequency (81U/O) Rotary field direction (47) Trip circuit supervision (74TC), Lock out (86), Change setting groups, Monitoring functions, Control of circuit breaker, Flexible protection functions (parameters from voltage), Frequency change / voltage change protection . | |
7RW8010-5EB00-1DC0 | Voltage and frequency relay Enclosure 1/6 19", 3 x V, 3 BI, 5 BO, (2 change-over contacts), 1 live contact . Auxiliary voltage: 60/110/125/220/250 V DC, 115 V AC, 230 V AC Installation encl., Screw terminals Region world, IEC/ANSI Language English (language can be changed) Front foil standard no system interface without system interface, Port A Measurement: with fault recording and min./max. values of voltages Functionality: Voltage,frequency protection and synchro check Overvoltage/Undervoltage (27/59), Underfrequency/Overfrequency (81U/O), Synchro check (25), Rotating field direction (47), Trip circuit supervision (74TC), Lock out (86), Parameter set switchover, Monitoring functions, Control of circuit breaker, Flexible protection functions (Parameters from voltage) Frequency change protection, Voltage change protection . | |
7RW8010-5EB00-1DD0 | Voltage and frequency relay Enclosure 1/6 19", 3 x V, 3 BI, 5 BO, (2 change-over contacts), 1 live contact . Auxiliary voltage: 60/110/125/220/250 V DC, 115 V AC, 230 V AC Installation encl., Screw terminals Region world, IEC/ANSI Language English (language can be changed) Front foil standard no system interface without system interface, Port A Measurement: with fault recording and min./max. values of voltages Functionality: Voltage protection, Frequency protection, Over- excitation protection and vector shift Overvoltage/Undervoltage (27/59), Displacement voltage (64/59N), Underfrequency/Overfrequency (81U/O), Overexcitation protection (24), Vector shift Rotating field direction (47), Trip circuit supervision (74TC), Lock out (86), Parameter set switchover, Monitoring functions, Control of circuit breaker, Flexible protection functions (Parameters from voltage) Frequency change protection, Voltage change protection . | |
7RW8010-5EB10-1DA0 | VOLTAGE AND,FREQUENCY RELAY HOUSING 1/6 19", 3 X V, 3 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT . RATED AUXILIARY VOLTAGE 60 TO 250V DC, 115V AC, 230V AC FLUSH-MOUNTING HOUSING, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) IEC60870-5-103 O. DIGSI4/MODEM, ELECTRICAL RS232 NO SYSTEM PORT A MEASURING: WITH FAULT RECORDING, AVERAGE VALUES, MIN/MAX VALUES FUNCTIONALITY: VOLTAGE AND FREQUENCY PROTECT. UNDER/OVERVOLTAGE (27/59) DISPLACEMENT VOLTAGE (64/59N), UNDER/OVERFREQUENCY (81U/O) PHASE ROTATION (47) TRIP CIRCUIT SUPERVISION (74TC) LOCK OUT (86) PARAMETER CHANGEOVER, MONITORING FUNCTIONS, CONTROL OF CIRCUIT BREAKER FLEXIBLE PROTECTION FUNCTIONS (VOLTAGE PARAMETERS) RATE-OF-FREQUENCY CHANGE, RATE-OF-VOLTAGE CHANGE . | |
7RW8010-5EB26-1DE0 | Voltage and frequency relay Enclosure 1/6 19", 3 x V, 3 BI, 5 BO, (2 change-over contacts), 1 live contact . Auxiliary voltage: 60/110/125/220/250 V DC, 115 V AC, 230 V AC Installation encl., Screw terminals Region world, IEC/ANSI Language English (language can be changed) Front foil standard System interface port B (underside of device, rear) IEC60870-5-103 or DIGSI4/modem electrical RS 485 interface, Port A (underside of device, on front) with Ethernet interface (DIGSI interface, not IEC61850) RJ45 connector Measurement: with fault recording and min./max. values of voltages Functionality: Voltage protection,Frequency protection, Over- excitation protection, Vector shift, Load connection + synchro check Overvoltage/Undervoltage (27/59), Underfrequency/Overfrequency (81U/O), Overexcitation protection (24), Vector shift, Load connection, Synchro check (25), Rotating field direction (47), Trip circuit supervision(74TC), Lock out (86), Parameter set switchover, Monitoring functions, Control of circuit breaker, Flexible protection functions (Parameters from voltage) Frequency change protection,(*) . |