Searching...
Nothing found.
[[ item.description.prodDescription ]]
This Product is on your Inquiry List.
7ML5034-1AC01
Manufacturer: SIEMENS
Price: On Request
Siemens HydroRanger 200 Ultrasonic level controller for up to six pumps that provides control, differential control and open channel flow monitoring. Mounting: Wall mount, standard enclosure Input voltage: 100 to 230 VAC Number of measurement points: Single point version, level only 1 relay Data Communications: Without module Approvals: General Purpose CE, FM, CSA US/C , UL listed, RCM, EAC, KCC
Similar items in same category:
7ML5034-..... | Siemens HydroRanger 200 Ultrasonic level controller for up to six pumps that provides control, differential control and open channel flow monitoring. | |
7ML5034-1AA01 | SIEMENS HYDRORANGER 200 ULTRASONIC LEVEL CONTROLLER FOR UP TO SIX PUMPS THAT PROVIDES CONTROL, DIFFERENTIAL CONTROL AND OPEN CHANNEL FLOW MONITORING. THE HYDRORANGER 200 IS ALSO AVAILABLE AS A LEVEL MEASUREMENT CONTROLLER ONLY. SELECT OPTION FROM MODEL CODE BELOW. MOUNTING: WALL MOUNT, STANDARD ENCLOSURE INPUT VOLTAGE: 100 TO 230 VAC NUMBER OF MEASUREMENT POINTS: SINGLE POINT VERSION, 6 RELAYS DATA COMMUNICATIONS: WITHOUT MODULE APPROVALS: GENERAL PURPOSE, CE, CSA US/C, FM, UL LISTED | |
7ML5034-1AA02 | Siemens HydroRanger 200 Ultrasonic level controller for up to six pumps that provides control, differential control and open channel flow monitoring. Mounting: Wall mount, standard enclosure Input voltage: 100 to 230 VAC Number of measurement points: Single point model, 6 relays Data Communications: Without module Approvals: CSA Class I, Div.2, Group A,B,C and D; Class II, DIV 2, Group F and G, Class III (for wall mount applications only) | |
7ML5034-1AB01 | Siemens HydroRanger 200 Ultrasonic level controller for up to six pumps that provides control, differential control and open channel flow monitoring. Mounting: Wall mount, standard enclosure Input voltage: 100 to 230 VAC Number of measurement points: Dual point model, 6 relays Data Communications: Without module Approvals: General Purpose CE, FM, CSA US/C , UL listed, RCM, EAC, KCC | |
7ML5034-1AD01 | Siemens HydroRanger 200 Ultrasonic level controller for up to six pumps that provides control, differential control and open channel flow monitoring. Mounting: Wall mount, standard enclosure Input voltage: 100 to 230 VAC Number of measurement points: Single point version, level only, 3 relays Data Communications: Without module Approvals: General Purpose CE, FM, CSA US/C , UL listed, RCM, EAC, KCC | |
7ML5034-1BA01 | Siemens HydroRanger 200 Ultrasonic level controller for up to six pumps that provides control, differential control and open channel flow monitoring. Mounting: Wall mount, standard enclosure Input voltage: 12 to 30 VDC Number of measurement points: Single point model, 6 relays Data Communications: Without module Approvals: General Purpose CE, FM, CSA US/C , UL listed, RCM, EAC, KCC | |
7ML5034-2AA01 | SIEMENS HYDRORANGER 200 ULTRASONIC LEVEL CONTROLLER FOR UP TO SIX PUMPS THAT PROVIDES CONTROL, DIFFERENTIAL CONTROL AND OPEN CHANNEL FLOW MONITORING. THE HYDRORANGER 200 IS ALSO AVAILABLE AS A LEVEL MEASUREMENT CONTROLLER ONLY. SELECT OPTION FROM MODEL CODE BELOW. MOUNTING: WALL MOUNT, 4 ENTRIES, 4 M20 CABLE GLANDS INCLUDED INPUT VOLTAGE: 100 TO 230 VAC NUMBER OF MEASUREMENT POINTS: SINGLE POINT VERSION, 6 RELAYS DATA COMMUNICATIONS: WITHOUT MODULE APPROVALS: GENERAL PURPOSE, CE, CSA US/C, FM, UL LISTED | |
7ML5034-2AA01-ZY15 | SIEMENS HYDRORANGER 200 ULTRASONIC LEVEL CONTROLLER FOR UP TO SIX PUMPS THAT PROVIDES CONTROL, DIFFERENTIAL CONTROL AND OPEN CHANNEL FLOW MONITORING. THE HYDRORANGER 200 IS ALSO AVAILABLE AS A LEVEL MEASUREMENT CONTROLLER ONLY. SELECT OPTION FROM MODEL CODE BELOW. MOUNTING: WALL MOUNT, 4 ENTRIES, 4 M20 CABLE GLANDS INCLUDED INPUT VOLTAGE: 100 TO 230 VAC NUMBER OF MEASUREMENT POINTS: SINGLE POINT VERSION, 6 RELAYS DATA COMMUNICATIONS: WITHOUT MODULE APPROVALS: GENERAL PURPOSE, CE, CSA US/C, FM, UL LISTED STAINLESS STEEL TAG: (69 X 50 MM (2.7 X 1.97")) MEASURING-POINT NUMBER/ IDENTIFICATION (MAX. 27 CHARACTERS), SPECIFY IN PLAIN TEXT |