Searching...
Nothing found.
[[ item.description.prodDescription ]]
This Product is on your Inquiry List.
7ML5033-2AA10-1A
Manufacturer: SIEMENS
Price: On Request
MultiRanger 100/200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) range. Monitors level, volume, and open channel flow in liquids, slurries, and solids. Versions: MultiRanger 200, level, volume, flow and differential measurements Mounting, enclosure design: Wall mount, standard enclosure Input voltage: 100 to 230 VAC Number of measurement points: Dual point version Data Communications (Smartlinx): Without module Output relays: 3 relays (2 Form A, 1 Form C), 250 V AC Approvals: General Purpose, CE, FM,CSA US/C,UL, listed, RCM,EAC,KCC
Similar items in same category:
7ML5033-2AA00-1A | MultiRanger 100/200 Versatile short to medium- range ultrasonic single and multi-vessel level monitor/controller for virtually any application in a wide range of industries Versions: MultiRanger 200, level, volume, flow and differential measurements Mounting, enclosure design: Wall nount, standard enclosure Input voltage: 100 to 230 VAC Number of measurement points: Single point version Data Communications (Smartlinx): Without module Output relays: 3 relays (2 Form A, 1 Form C), 250 V AC Approvals: General Purpose, CE, FM,CSA US/C,UL, listed, RCM,EAC,KCC | |
7ML5033-2AA00-1B | MultiRanger 200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) range. Monitors level, volume, and open channel flow in liquids, slurries, and solids. Versions: MultiRanger 200, level, volume, flow and differential measurements Mounting, enclosure design: Wall mount, standard enclosure Input voltage: 100 to 230 VAC Number of measurement points: Single point version Data Communications (Smartlinx): Without module Output relays: 3 relays (2 Form A, 1 Form C), 250 V AC Approvals: CSA Class I, Div.2, Group A,B,C and D; Class II, Div.2, Group F and G; Class III | |
7ML5033-2AA00-2A | MultiRanger 100/200 Versatile short to medium- range ultrasonic single and multi-vessel level monitor/controller for virtually any application in a wide range of industries Versions: MultiRanger 200, level, volume, flow and differential measurements Mounting, enclosure design: Wall nount, standard enclosure Input voltage: 100 to 230 VAC Number of measurement points: Single point version Data Communications (Smartlinx): Without module Output relays: 6 relays (4 Form A, 2 Form C), 250 V AC Approvals: General Purpose, CE, FM,CSA US/C,UL, listed, RCM,EAC,KCC | |
7ML5033-2AA00-2B | MultiRanger 100/200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) range. Monitors level, volume, and open channel flow in liquids, slurries, and solids. Versions: MultiRanger 200, level, volume, flow and differential measurements Mounting, enclosure design: Wall mount, standard enclosure Input voltage: 100 to 230 VAC Number of measurement points: Single point version Data Communications (Smartlinx): Without module Output relays: 6 relays (4 Form A, 2 Form C), 250 V AC Approvals: CSA Class I, Div.2, Group A,B,C and D; Class II, Div.2, Group F and G; Class III | |
7ML5033-2AA10-1C | MultiRanger 100/200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) range. Monitors level, volume, and open channel flow in liquids, slurries, and solids. Versions: MultiRanger 200, level, volume, flow and differential measurements Mounting, enclosure design: Wall mount, standard enclosure Input voltage: 100 to 230 VAC Number of measurement points: Dual point version Data Communications (Smartlinx): Without module Output relays: 3 relays (2 Form A, 1 Form C), 250 V AC Approvals: ATEX II 3D | |
7ML5033-2AA10-2A | MultiRanger 100/200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) range. Monitors level, volume, and open channel flow in liquids, slurries, and solids. Versions: MultiRanger 200, level, volume, flow and differential measurements Mounting, enclosure design: Wall mount, standard enclosure Input voltage: 100 to 230 VAC Number of measurement points: Dual point version Data Communications (Smartlinx): Without module Output relays: 6 relays (4 Form A, 2 Form C), 250 V AC Approvals: General Purpose, CE, FM,CSA US/C,UL, listed, RCM,EAC,KCC | |
7ML5033-2AA10-2B | MultiRanger 100/200 Versatile short to medium- range ultrasonic single and multi-vessel level monitor/controller for virtually any application in a wide range of industries Versions: MultiRanger 200, level, volume, flow and differential measurements Mounting, enclosure design: Wall nount, standard enclosure Input voltage: 100 to 230 VAC Number of measurement points: Dual point version Data Communications (Smartlinx): Without module Output relays: 6 relays (4 Form A, 2 Form C), 250 V AC Approvals: CSA Class I, Div.2, Group A,B,C and D; Class II, Div.2, Group F and G; Class III | |
7ML5033-2AA12-2B | MultiRanger 100/200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) range. Monitors level, volume, and open channel flow in liquids, slurries, and solids. Versions: MultiRanger 200, level, volume, flow and differential measurements Mounting, enclosure design: Wall mount, standard enclosure Product is in phase out but still available to order, Consider replacing with 7ML5033-xD Input voltage: 100 to 230 VAC Number of measurement points: Dual point version Data Communications (Smartlinx): Smartlinx PROFIBUS DPVO module Output relays: 6 relays (4 Form A, 2 Form C), 250 V AC Approvals: CSA Class I, Div.2, Group A,B,C and D; Class II, Div.2, Group F and G; Class III |