7MF4033-1CC10-2AC6

7MF4033-1CC10-2AC6

Manufacturer: SIEMENS

Price: On Request

SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,04 ... 4 bar g (0.58 ... 58 psi g), overload limit 10 bar Seal diaphragm: Hastelloy, Process connection: Hastelloy Female thread 1/2-14 NPT Die-cast aluminium housing International design english inscription and documentation as cd None explosion protection Electric connection and cable inlet: cable gland 1/2-14 npt Housing cover with window


Similar items in same category:
7MF4033-1CA10-1BC7-ZA01+Y01+Y15+Y21+C11+C12 7MF4033-1CA10-1BC7-ZA01+Y01+Y15+Y21+C11+C12 SITRANS P DS III, HART,4-20 MA TRANSMITTER FOR PRESSURE MEASURING CELL FILLING SILICONE OIL, NORMAL CLEANING SPAN: 0,04 ... 4 BAR G (0.58 ... 58 PSI G), OVERLOAD LIMIT 10 BAR DIAPHRAGM STAINLESS STEEL, MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: FEMALE THREAD 1/2-14 NPT DIE-CAST ALUMINIUM HOUSING STANDARD DESIGN EXPLOSION PROTECTION EEX IA ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND 1/2-14 NPT HOUSING COVER WITH WINDOW (DIGITAL INDICATOR VISIBLE, CUSTOMIZED ADJUSTMENT SUPPLEMENT Y21 REQUIRED) WITH STEEL MOUNTING BRACKET RANGE (LINEAR CHARACTERISTIC) SPECIFY IN PLAIN TEXT:, Y01:... TO ...MBAR,KPA,MPA,... STAINLESS STEEL TAG PLATE (MEASURING POINT DESCRIPTION) MAX.16 CHARACTER, SPECIFY IN PLAIN TEXT: ADJUSTMENT DIGITAL INDICATOR SPECIFY PLAIN TEXT Y21: MBAR, BAR, KPA, MPA,... QUALITY INSPECTION CERTIFICATE (FACTORY CALIBRATION) TO IEC 60770-2 ACCEPTANCE TEST CERTIFICATE B TO DIN 50 049 / EN 10 204-3.1 B
7MF4033-1CA10-1NC6 7MF4033-1CA10-1NC6 SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,04 ... 4 bar g (0.58 ... 58 psi g), overload limit 10 bar Diaphragm stainless steel, measuring cell stainless steel Female thread 1/2-14 NPT Die-cast aluminium housing Standard design Explosion protection fm + csa Electric connection and cable inlet: cable gland 1/2-14 npt Housing cover with window
7MF4033-1CA23-1BB6 7MF4033-1CA23-1BB6 SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,04 ... 4 bar g (0.58 ... 58 psi g), overload limit 10 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: oval flange and connection shank: stainless steel max. span: 400 bar mounting thread: 7/16-20 unf Housing made of stainless steel precision casting Standard design Explosion protection EEx ia Electric connection and cable inlet: cable gland M20 x 1.5 Housing cover with window
7MF4033-1CA60-2AC6 7MF4033-1CA60-2AC6 SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,04 ... 4 bar g (0.58 ... 58 psi g), overload limit 10 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: Male thread 1/2-14NPT Die-cast aluminium housing International design english inscription and documentation as cd None explosion protection Electric connection and cable inlet: cable gland 1/2-14 npt Housing cover with window
7MF4033-1CY00-2AC7 7MF4033-1CY00-2AC7 SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,04 ... 4 bar g (0.58 ... 58 psi g), overload limit 10 bar Version for diaphragm pressure controller. Consider additional delivery time for Remote seal. Remote seals must be ordered with an additional article no. Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing International design english inscription and documentation as cd None explosion protection Electric connection and cable inlet: cable gland 1/2-14 npt Housing cover with window (digital indicator visible, customized adjustment supplement Y21 required)
7MF4033-1DA00-1AA6 7MF4033-1DA00-1AA6 SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,16 ... 16 bar g (2.32 ... 232 psi g), overload limit 32 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing Standard design None explosion protection Electric connection and cable inlet: screwed gland PG 13.5 Housing cover with window
7MF4033-1DA00-1AB6 7MF4033-1DA00-1AB6 SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,16 ... 16 bar g (2.32 ... 232 psi g), overload limit 32 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing Standard design None explosion protection Electric connection and cable inlet: cable gland M20 x 1.5 Housing cover with window
7MF4033-1DA00-1AC6 7MF4033-1DA00-1AC6 SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,16 ... 16 bar g (2.32 ... 232 psi g), overload limit 32 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing Standard design None explosion protection Electric connection and cable inlet: cable gland 1/2-14 npt Housing cover with window