• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.
7MF1566-3AC00-1CA1

7MF1566-3AC00-1CA1

Manufacturer: SIEMENS

Price: On Request

SITRANS P210 Transmitters for pressure and absolute pressure for low-pressure applications Non-linearity: 0,25 percent (typically) wetted parts material: stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 250 mbar, Overload- pressure 1000 mbar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland M16 (with connector) Process connection: G1/4" male thread to EN837-1 (1/4"-BSP male) Sealing material between sensor and housing: Viton (FPM, Standard) Standard version


Similar items in same category:
7MF1566-3AB00-1AA1 7MF1566-3AB00-1AA1 SITRANS P210 Transmitters for pressure and absolute pressure for low-pressure applications Non-linearity: 0,25 percent (typically) wetted parts material: stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 160 mbar, Overload- pressure 400 mbar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland M16 (with connector) Process connection: G1/2" male to EN 837-1 (1/2" BSP male) (standard for metric pressure ranges mbar, bar) Sealing material between sensor and housing: Viton (FPM, Standard) Standard version
7MF1566-3AB00-1AA4 7MF1566-3AB00-1AA4 SITRANS P210 AESA Transmitter for gage pressure with internal FPM sealing non-linearity 0,25% (typic.) wetted parts material: ceramics, stainless steel non-wetted parts material: stainless steel Measuring range for gauge:0 to 160 mbar, Overload-press. 400 mbar Output signal: 4 to 20 mA two-wire connection power supply DC 7 to 33V without explosion protection Electrical connection: plug to DIN EN 175301-803-A, with connector M16; Process Connection: G1/2" to EN837-1 Special version for AESA/D
7MF1566-3AC00-1AA1 7MF1566-3AC00-1AA1 SITRANS P210 Transmitters for pressure and absolute pressure for low-pressure applications Non-linearity: 0,25 percent (typically) wetted parts material: stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 250 mbar, Overload- pressure 1000 mbar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland M16 (with connector) Process connection: G1/2" male to EN 837-1 (1/2" BSP male) (standard for metric pressure ranges mbar, bar) Sealing material between sensor and housing: Viton (FPM, Standard) Standard version
7MF1566-3AC00-1AA4 7MF1566-3AC00-1AA4 SITRANS P210 AESA Transmitter for gage pressure with internal FPM sealing non-linearity 0,25% (typic.) wetted parts material: ceramics, stainless steel non-wetted parts material: stainless steel Measuring range for gauge:0 to 250 mbar, Overload-press. 1bar Output signal: 4 to 20 mA two-wire connection power supply DC 7 to 33V without explosion protection Electrical connection: plug to DIN EN 175301-803-A, with connector M16; Process Connection: G1/4" to EN837-1 Special version for AESA/D
7MF1566-3AC01-2FA1 7MF1566-3AC01-2FA1 SITRANS P210 Transmitters for pressure and absolute pressure for low-pressure applications Non-linearity: 0,25 percent (typically) wetted parts material: stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 250 mbar, Overload- pressure 1000 mbar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V Explosion protection: EEx ia Electrical connection: round plug M12 to IEC 61076-2-101 Process connection: 1/4"-18 NPT female Sealing material between sensor and housing: Viton (FPM, Standard) Standard version
7MF1566-3AD00-1AA1 7MF1566-3AD00-1AA1 SITRANS P210 Transmitters for pressure and absolute pressure for low-pressure applications Non-linearity: 0,25 percent (typically) wetted parts material: stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 400 mbar, Overload- pressure 1000 mbar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland M16 (with connector) Process connection: G1/2" male to EN 837-1 (1/2" BSP male) (standard for metric pressure ranges mbar, bar) Sealing material between sensor and housing: Viton (FPM, Standard) Standard version
7MF1566-3AD00-1AA4 7MF1566-3AD00-1AA4 SITRANS P210 AESA Transmitter for gage pressure with internal FPM sealing non-linearity 0,25% (typic.) wetted parts material: ceramics, stainless steel non-wetted parts material: stainless steel Measuring range for gauge:0 to 40 mbar, Overload-press. 1 bar Output signal: 4 to 20 mA two-wire connection power supply DC 7 to 33V without explosion protection Electrical connection: plug to DIN EN 175301-803-A, with connector M16; Process Connection: G1/2" to EN837-1 Special version for AESA/D
7MF1566-3AD00-1AB1 7MF1566-3AD00-1AB1 SITRANS P210 Transmitters for pressure and absolute pressure for low-pressure applications Non-linearity: 0,25 percent (typically) wetted parts material: stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 400 mbar, Overload- pressure 1000 mbar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland M16 (with connector) Process connection: G1/2" male to EN 837-1 (1/2" BSP male) (standard for metric pressure ranges mbar, bar) Sealing material between sensor and housing: Neoprene (CR) Standard version