Searching...
Nothing found.
[[ item.description.prodDescription ]]
This Product is on your Inquiry List.
7ME612.-.....-....
Manufacturer: SIEMENS
Price: On Request
SITRANS F M MAGFLO MAG 1100 High temperature
Similar items in same category:
7ME6110-3MA20-2AA1 | SITRANS FM MAG 1100 Electromagnetic flow sensor, wafer design, diameter DN 2 to DN 100 (1/12" to 4"). Suitable for volume flow measurement of liquids (conductive) , for applications in water & wastewater, pharmaceutical and chemical industry. . DN80, 3 Inch Without process connection Ceramic . Platinum (only with ceramic liner) Sensor for remote transmitter (order transmitter separately) No bus communication Metric Polyamid terminal box or 6000 I compact. | |
7ME6110-3MA20-2AA2 | SITRANS FM MAG 1100 Electromagnetic flow sensor, wafer design, diameter DN 2 to DN 100 (1/12" to 4"). Suitable for volume flow measurement of liquids (conductive) , for applications in water & wastewater, pharmaceutical and chemical industry. . DN80, 3 Inch Without process connection Ceramic . Platinum (only with ceramic liner) Sensor for remote transmitter (order transmitter separately) No bus communication 1/2 inch NPT Polyamid Terminal or 6000 I compact. | |
7ME6110-3TA10-1AA2 | SITRANS FM MAG 1100 Electromagnetic flow sensor, wafer design, diameter DN 2 to DN 100 (1/12" to 4"). Suitable for volume flow measurement of liquids (conductive) , for applications in water & wastewater, pharmaceutical and chemical industry. . DN100, 4 Inch Without process connection PFA (no ATEX) . Hastelloy C (only with PFA liner) Sensor for remote transmitter (order transmitter separately) No bus communication 1/2 inch NPT Polyamid Terminal or 6000 I compact. | |
7ME6110-3TA20-2JB1 | SITRANS F M MAGFLO MAG 1100 . DN100, 4 Inch Without process connection Ceramic . Platinum (only with ceramic liner) MAG 6000, IP67 / NEMA 4X/6, Polyamid enclosure, With display, 115-230V AC 50/60 Hz HART Metric Polyamid terminal box or 6000 I compact. | |
7ME613.-.....-.... | SITRANS F M MAGFLO MAG 1100 EX, ATEX | |
7ME614.-.....-.... | SITRANS F M MAGFLO MAG 1100 Food | |
7ME6140-1RA20-2AA1 | SITRANS FM MAG 1100 F Full-bore electromagnetic flow sensor, sanitary design, diameter DN 10 to DN 100 (3/8" to 4"). Suitable for volume flow measurement of liquids (conductive) , for applications in F&B, pharmaceutical industry. . DN10, 3/8 Inch None (not 3A approved) Ceramic EPDM (FDA) Electrode material: Platinum Sensor for remote transmitter (order transmitter separately)- 3A approved No bus Communication Metric Polyamid terminal box (3A) or 6000 I compact. | |
7ME6140-1RB20-2KA1 | SITRANS FM MAG 1100 F Full-bore electromagnetic flow sensor, sanitary design, diameter DN 10 to DN 100 (3/8" to 4"). Suitable for volume flow measurement of liquids (conductive) , for applications in F&B, pharmaceutical industry. . DN10, 3/8 Inch Weld in connection fittings: DIN11850 Ceramic EPDM (FDA) Electrode material: Platinum MAG 5000, IP67 / NEMA 4X/6, Polyamid enclosure, With display, 11-30V DC/11-24V AC 50/60 Hz No bus Communication Metric cable glands, Polyamid terminal box or MAG 6000i integral mount |