• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.
7ME348.-.....-....

7ME348.-.....-....

Manufacturer: SIEMENS

Price: On Request

SITRANS FUE950 calculator for energy metering. IP54 wall mount enclosure.


Similar items in same category:
7ME3410-5MC21-6BR2 7ME3410-5MC21-6BR2 Ultrasonic flowmeter for heat or cold measurement Measuring tube with built-in sound transducers in 2-path arrangement. Transmitter compact on the pipe or remote With MID004 approval for custody transfer flow measurements Siemens DN1000 (40") Carbon Steel, EN 1434, qp=12000m3/h, qs=16800m3/h, qi=120m3/h EN1092-1 PN16 Remote version, Sensor link cabel (SSL) 5 m, with gland, DN50 to DN80: max. 150°C (302°F), DN100 to DN800 max. 200°C (392°F) With CT approval Pulse value: 100 L/p Power supply 115 - 230V AC MID-Approval (MI004), Language on nameplate English Pulse width: 5 ms
7ME3440-0AA01-2DA4 7ME3440-0AA01-2DA4 Sparepart SITRANS F US: Spare part FUS880 kit, 1-path, USA version, FUS080 with 3.6V bat.-pack, Code 7ME3440-0AA01-2DA4: Label(7ME3440): Siemens. Diameter(0A): Standard setting. Wall thickness(A): Standard setting. Pipe material(0): Standard setting. Path config.(1): 1-path. Region version(2): For USA, units AcFt, CFS . Transmitter(D): FUS080 with unit label, IP67/NEMA 4X/6, 3.6V bat.pack wall-mount. kit. Version (A): Standard. Transducer cable (4): 2 sensor cable, 20 m (60 ft), incl. gland and 2 transducer.
7ME3440-0AA03-2DA4 7ME3440-0AA03-2DA4 Sparepart SITRANS F US: Spare part FUS880 kit, 2-path, USA version, FUS080 with 3.6V bat.-pack, Code 7ME3440-0AA03-2DA4: Label(7ME3440): Siemens. Diameter(0A): Standard setting. Wall thickness(A): Standard setting. Pipe material(0): Standard setting. Path config.(3): 2-path. Region version(2): For USA, units AcFt, CFS . Transmitter(D): FUS080 with unit label, IP67/NEMA 4X/6, 3.6V bat.pack wall-mount. kit. Version (A): Standard. Transducer cable (4): 4 sensor cable, 20 m (60 ft), incl. gland and 4 transducer.
7ME347.-.....-.... 7ME347.-.....-.... SITRANS FUE950 arithmetic logic unit FOR HEAT QUANTITY MEASUREMENT. IP54 WALL HOUSING.
7ME3480-2AA62-2BC0 7ME3480-2AA62-2BC0 SITRANS FUE950 calculator for energy metering. IP54 wall mount enclosure. Siemens FUE950 Flow input setting: Pulse value 1 L/Pulse, max. flow rate 360 m3/h, (with option L05: 1 gal/p., max. flow rate 6000 GPM). Application setting: For heating applications, Flowmeter placed at low temp. Temperature senor type: PT500 sensor pair (6/50 mm), with EN1434 approval, 2-wire with 5 m connection cable. Sensor with 6 mm diameter and 50 mm length. Temperature sensor pockets: Brass pockets for 6 mm 2-wire sensors, 82/92 mm - G1/2", max. PN16 & 1 m/s, (2 pcs.). VOLTAGE SUPPLY: WITH POWER SUPPLY UNIT FOR 230 V AC 50 HZ SUPPLY (INCL. BACKUP BATTERY). Option modules : One M-Bus module. Display units & resolution: MWh, kW, m3, m3/h - 2 digit resolution. Approval / Verification: Without type approval mark, neutral label (in English).
7ME3480-2AB66-3DC0 7ME3480-2AB66-3DC0 SITRANS FUE950 Custody transfer approved energy calculator, for use with flow meters of type FUS380, FUE380, MAG 8000, FS220 and MAG 5000/6000 transmitter. Suitable for thermal energy measurement of liquids for applications in district heating and chiller plants. - Pulse value 1 L/Pulse, max. flow rate 360 m3/h (with option L05: 1 gal/p., max. flow rate 6000 GPM). For heating applications, Flowmeter placed at hot temperture (MID conform). PT500 sensor pair (6/50 mm), with EN1434 approval, 2-wire with 5 m connection cable, Sensor with 6 mm diameter and 50 mm length. Stainless steel pockets for 2-wire sensors, 117/127 mm - G1/2", max. PN25 & 1 m/s, (2 pcs.). Power supply Mains powered with 24 VAC module (incl. back-up battery). Module 1 RS-485 (M-Bus). MWh, kW, m3, m3/h - 2 digit resolution. Calculator without EU type approval. For operational measurements in heat or cold applications.
7ME3480-2BB00-2BD1 7ME3480-2BB00-2BD1 SITRANS FUE950 calculator for energy metering. IP54 wall mount enclosure. Siemens FUE950 Flow input setting: Pulse value 2.5 L/Pulse, max. flow rate 900 m3/h, (with option L05: 2.5 gal/p., max. flow rate 15000 GPM). Application setting: For heating applications, Flowmeter placed at hot temp. Temperature sensor type: PT500 set-up, no sensor incl. Temperature sensor pockets: No senor pockets included. VOLTAGE SUPPLY: WITH POWER SUPPLY UNIT FOR 230 V AC 50 HZ SUPPLY (INCL. BACKUP BATTERY). Option modules : One M-Bus module. Display units and resolution: MWh, kW, m3, m3/h - 1 digit resolution. Approval / Verification: With MID type approval mark (only for heating application).
7ME3480-2BC00-2HD0 7ME3480-2BC00-2HD0 SITRANS FUE950 calculator for energy metering. IP54 wall mount enclosure. Siemens FUE950 Flow input setting: Pulse value 2.5 L/Pulse, max. flow rate 900 m3/h, (with option L05: 2.5 gal/p., max. flow rate 15000 GPM). Application setting: For cooling applications, Flowmeter placed at low temp. Temperature sensor type: PT500 set-up, no sensor incl. Temperature sensor pockets: No senor pockets included. VOLTAGE SUPPLY: WITH POWER SUPPLY UNIT FOR 230 V AC 50 HZ SUPPLY (INCL. BACKUP BATTERY). Option modules: M-Bus module and Pulse output. module (2 pulse outputs). Display units and resolution: MWh, kW, m3, m3/h - 1 digit resolution. Approval / Verification: Without type approval mark, neutral label (in English).