7MB2111-0CW00-1AA1
Manufacturer: SIEMENS
Price: On Request
ULTRAMAT 6 gas analyzer, for installation in the field, single-channel, 1 component Ferrule screw connection for pipe, outer diameter 6mm CO2 Smallest measuring range: 0 to 30 %, largest measuring range: 0 to 100 % Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type Without 200 to 240 V AC, 48 to 63 Hz Without ., English
Similar items in same category:
7MB2041-3CA10-1AA1 | Gas Analyzer OXYMAT 64, 19" unit for installation in cabinets ZrO2: Catalytically inactive cell (CIC); with differential pressure sensor Low pressure, with pump (Atmosphere) Input: clamping ring connection 6 mm, output: Fittings 6 mm Gas monitoring: Flowmeter and limit switch (internal) Without AC 200 to 240 V, 48 to 63 Hz Without . English | |
7MB2047-.....-.... | GASANALYZER OXYMAT 64, SPECIAL APPLICATION | |
7MB2111-.....-.... | ULTRAMAT 6 gas analyzer, for installation in the field, single-channel, 1 component | |
7MB2111-0AD60-7AA1 | ULTRAMAT 6 Field device gas analyzer, for installation in the field, single-channel, 1 component Ferrule screw connection for pipe, outer diameter 6mm CO Smallest measuring range: 0 to 50 vpm, largest measuring range: 0 to 1000 vpm Internal gas path: stainless steel pipe (mat. no. 1.4571), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type Without 200 to 240 V AC, 48 to 63 Hz , according to ATEX II 2G (operating mode: continuous purging) Without ., English | |
7MB2111-1AB60-6AA1 | ULTRAMAT 6 Field device gas analyzer, for installation in the field, single-channel, 1 component Ferrule screw connection for pipe, outer diameter 1/4" CO Smallest measuring range: 0 to 10 vpm, largest measuring range: 0 to 200 vpm Internal gas path: stainless steel pipe (mat. no. 1.4571), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type Without 100 V to 120 V AC, 48 to 63 Hz (operating mode: continuous purging) according to ATEX II 2G Ex px ia[ia] op is IIC T6..T4 Gb Without ., English | |
7MB2111-1CA00-1AA1 | ULTRAMAT 6 Field device gas analyzer, for installation in the field, single-channel, 1 component Ferrule screw connection for pipe, outer diameter 1/4" CO2 Smallest measuring range: 0 to 5 vpm, largest measuring range: 0 to 100 vpm Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type Without 200 to 240 V AC, 48 to 63 Hz Without ., English | |
7MB2111-1CA30-7AA1 | ULTRAMAT 6 Field device gas analyzer, for installation in the field, single-channel, 1 component Ferrule screw connection for pipe, outer diameter 1/4" CO2 Smallest measuring range: 0 to 5 vpm, largest measuring range: 0 to 100 vpm Internal gas path: Pipe made of titanium, sample chamber (lining): Tantalum, reference chamber (flow-type): flow-type Without 200 to 240 V AC, 48 to 63 Hz , according to ATEX II 2G (operating mode: continuous purging) Without ., English | |
7MB2111-1CD60-6AA1 | ULTRAMAT 6 gas analyzer, for installation in the field, single-channel, 1 component Ferrule screw connection for pipe, outer diameter 1/4" CO2 Smallest measuring range: 0 to 50 vpm, largest measuring range: 0 to 1000 vpm Internal gas path: stainless steel pipe (mat. no. 1.4571), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type Without 100 to 120 V AC, 48 to 63 Hz , according to ATEX II 2G (operating mode: continuous purging) Without ., English |