Searching...
Nothing found.
[[ item.description.prodDescription ]]
This Product is on your Inquiry List.
4AV3597-0AE00-0AT1
Manufacturer: SIEMENS
Price: On Request
POWER SUPPLY; PHASES:3; PN(KW):1,2; UPRI(V):440; USEC(V DC):24; ISEC(A DC):50; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YY6 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):5; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61131-2; EN 61558 >SAFETY ISOLATING TRANSFORMER<
Similar items in same category:
4AV3596-0EG30-0C | POWER SUPPLY; PHASES:3; PN(KW):1,2; UPRI(V):480-400; USEC(V DC):48; ISEC(A DC):25; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YNY0 /0; PROTECTION CL.:I; TA/ISOKL:40 /B; W(%):5; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN61558 EN61131-2 >SAFETY ISOLATING TRANSFORMER< | |
4AV3596-0EG40-0C | POWER SUPPLY; PHASES:1; PN(KW):1; UPRI(V):400+/-20; 230+/-10; USEC(V DC):36; ISEC(A DC):30; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YY0 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):5; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-6 | |
4AV3596-0EG50-0C | POWER SUPPLY; PHASES:3; PN(KW):1,2; UPRI(V):115; USEC(V DC):48; ISEC(A DC):25; F(HZ):400...400; VECTOR GR./SHIELD WNG.:YNY0 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):5; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN61558 EN61131-2 | |
4AV3597-0AE00-0A | POWER SUPPLY; PHASES:3; PN(KW):1,2; UPRI(V):440; USEC(V DC):24; ISEC(A DC):50; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YY6 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):5; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61131-2; EN 61558 >SAFETY ISOLATING TRANSFORMER< | |
4AV3597-0AQ00-0A | POWER SUPPLY; PHASES:1; PN(KW):1,2; UPRI(V):440+/-20; USEC(V DC):24(DC)(50ADC); ISEC(A DC):50; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YY0 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):5; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-1 | |
4AV3597-0EB30-0A | POWER SUPPLY; PHASES:3; PN(KW):0,65; UPRI(V):400+/-5%; USEC(V DC):13; ISEC(A DC):50; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YY0 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):5; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-6 >SAFETY ISOLATING TRANSFORMER< | |
4AV3597-0EB60-0A | RECTIFIER UNIT; PHASES:1; PN(KW):1,2; UPRI(V):480; USEC(V DC):24; ISEC(A DC):50/60 (60 C/40 C); F(HZ):50...60; VECTOR GR./SHIELD WNG.:YY0 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):5; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-6, EN 61131-2 >UL/CSA-RECOGNIZED<>SAFETY ISOLATING TRANSFORMER< | |
4AV3597-0EB60-0C | RECTIFIER UNIT; PHASES:3; PN(KW):1,2; UPRI(V):480; USEC(V DC):24; ISEC(A DC):50; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YY0 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):5; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN61558 ; EN61131-2 >UL/CSA-RECOGNIZED< >SAFETY ISOLATING TRANSFORMER< |