• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.
4AV3296-0BQ00-0A

4AV3296-0BQ00-0A

Manufacturer: SIEMENS

Price: On Request

POWER SUPPLY; PHASES:3; PN(KW):0,48; UPRI(V):480-460-440-415-400; USEC(V DC):24; ISEC(A DC):20; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YD1 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):5; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-2, -2-6 >SAFETY ISOLATING TRANSFORMER<


Similar items in same category:
4AV3296-0BC00-0A 4AV3296-0BC00-0A POWER SUPPLY; PHASES:3; PN(KW):0,48; UPRI(V):400+/-20; USEC(V DC):48; ISEC(A DC):10; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YD1 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):4,2; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558 >SAFETY ISOLATING TRANSFORMER<
4AV3296-0BE00-0A 4AV3296-0BE00-0A POWER SUPPLY; PHASES:3; PN(KW):0,48; UPRI(V):460+/-5%; USEC(V DC):24; ISEC(A DC):20; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YY0 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):5; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558, EN 61131-2
4AV3296-0BL00-0A 4AV3296-0BL00-0A POWER SUPPLY; PHASES:3; PN(KW):0,48; UPRI(V):660; USEC(V DC):24; ISEC(A DC):20; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YY0 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):5; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558, EN 61131-2
4AV3296-0BP00-0A 4AV3296-0BP00-0A POWER SUPPLY; PHASES:3; PN(KW):0,48; UPRI(V):480-460-440-415-400; USEC(V DC):48; ISEC(A DC):10; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YD1 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):5; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-2, -2-6 ; EN 61131-2 >SAFETY ISOLATING TRANSFORMER<
4AV3296-0BS00-0A 4AV3296-0BS00-0A POWER SUPPLY; PHASES:1; PN(KW):0,48; UPRI(V):690+/-10%; USEC(V DC):24; ISEC(A DC):20; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YY6 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):5; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558, EN 61131-2
4AV3296-0BW00-0A 4AV3296-0BW00-0A POWER SUPPLY; PHASES:3; PN(KW):0,48; UPRI(V):500-480-460-440-420- 400-380; USEC(V DC):24; ISEC(A DC):20; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YD1 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):5; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558
4AV3296-0CH00-0A 4AV3296-0CH00-0A POWER SUPPLY; PHASES:1; PN(KW):0,48; UPRI(V):380+/-5%; USEC(V DC):24; ISEC(A DC):20; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YY0 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):5; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558, EN 61131-2 >SAFETY ISOLATING TRANSFORMER<
4AV3296-0CV00-0A 4AV3296-0CV00-0A POWER SUPPLY; PHASES:1; PN(KW):0,48; UPRI(V):460+/-5%; USEC(V DC):32; ISEC(A DC):15; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YY0 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):4; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558