4AV2496-0EB40-0A

4AV2496-0EB40-0A

Manufacturer: SIEMENS

Price: On Request

POWER SUPPLY; PHASES:1; PN(KW):0,144; UPRI(V):500-440-415-380-220; USEC(V DC):24 ; ISEC(A DC):6; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):3; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-6 >SAFETY ISOLATING TRANSFORMER<


Similar items in same category:
4AV2496-0CD00-0A 4AV2496-0CD00-0A POWER SUPPLY; PHASES:1; PN(KW):0,28; UPRI(V):400-230+/-15; USEC(V DC):35; ISEC(A DC):8; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; PROTECTION CL.:I; TA/ISOKL:50 /B; W(%):3; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-6 >SAFETY ISOLATING TRANSFORMER<
4AV2496-0CK00-0A 4AV2496-0CK00-0A POWER SUPPLY; PHASES:1; PN(KW):0,24; UPRI(V):480+/-5%; USEC(V DC):24 ; 24; ISEC(A DC):8 ; 2; F(HZ):50...60; VECTOR GR./SHIELD WNG.:III0 /0; PROTECTION CL.:I; TA/ISOKL:50 /B; W(%):3; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558 EN61131-2 >UL/CSA-RECOGNIZED< >SAFETY ISOLATING TRANSFORMER<
4AV2496-0CM00-0A 4AV2496-0CM00-0A POWER SUPPLY; PHASES:1; PN(KW):0,24; UPRI(V):400+/-5%; USEC(V DC):24 ; 24; ISEC(A DC):8 ; 2; F(HZ):50...60; VECTOR GR./SHIELD WNG.:III0 /0; PROTECTION CL.:I; TA/ISOKL:50 /B; W(%):3; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558 EN61131-2 >UL/CSA-RECOGNIZED< >SAFETY ISOLATING TRANSFORMER<
4AV2496-0EB20-0A 4AV2496-0EB20-0A POWER SUPPLY; PHASES:1; PN(KW):0,24; UPRI(V):460-400+/-20; USEC(V DC):24; ISEC(A DC):10; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):3; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN61558 ; EN61131-2 >SAFETY ISOLATING TRANSFORMER<
4AV2496-0EB50-0A 4AV2496-0EB50-0A POWER SUPPLY; PHASES:1; PN(KW):0,24; UPRI(V):400-230-115; USEC(V DC):48 ; ISEC(A DC):5; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):5; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-6 , EN61131-2 >SAFETY ISOLATING TRANSFORMER<
4AV2496-0EB60-0A 4AV2496-0EB60-0A POWER SUPPLY; PHASES:1; PN(KW):0,198; UPRI(V):220; USEC(V DC):18; ISEC(A DC):11; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; PROTECTION CL.:I; TA/ISOKL:40 /B; W(%):5; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-6 , EN61131-2
4AV2496-0EB70-0A 4AV2496-0EB70-0A POWER SUPPLY; PHASES:1; PN(KW):0,12; UPRI(V):400; USEC(V DC):12; ISEC(A DC):10; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):5; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558
4AV2496-0EB80-0A 4AV2496-0EB80-0A POWER SUPPLY; PHASES:1; PN(KW):0,12; UPRI(V):500+/-5%; USEC(V DC):12; ISEC(A DC):10; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):5; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558