• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.
2GA3643-4S

2GA3643-4S

Manufacturer: SIEMENS

Price: On Request

EXPERIMENTAL PANEL, CAN BE USED ALSO AS A DESKTOP UNIT, FREQUENCY CONVERTER MICROMASTER INPUT VOLTAGE 3AC 400V,50/60 HZ OUTPUT VOLTAGE 3 AC 0 - 400 V OUTPUT FREQUENCY 0 - 650 HZ, MOTOR RATED POWER 1.5 KW, CONTROL VIA U/F CHARACTERISTIC AND FCC


Similar items in same category:
2GA3643-4M 2GA3643-4M FREQUENCY CONV. MICRO-MASTER EXPERIMENTAL PANEL AND BENCH UNIT INPUT VOLTAGE AC 230V , 50/60HZ OUTPUT FREQUENCY 0 TO 400HZ PULSE FREQUENCY MAX. 16 KHZ OUTPUT RATING MAX. 250W OVERLOAD 60S , 150% BRAKING RESISTOR: 800W FOR 12S REGULATION AND CONTROL FCC (PULSE CURRENT CONTROL) VOLTAGE FREQUENCY CURVE INTERFACE: RS 485
2GA3643-4N 2GA3643-4N FREQUENCY CONV. MICRO-MASTER EXPERIMENT.PANEL AND BENCH UNIT INPUT VOLTAGE AC 230V , 50/60HZ OUTPUTVOLT. 3AC 0-230V, 50/60HZ OUTPUT FREQUENCY 0 - 400HZ PULSEFREQUENCY MAX. 16 KHZ OUTPUT RATING MAX. 1100W OVERLOAD 60S , 150% BRAKING RESISTOR: 800W FOR 12S REGULATION AND CONTROL: FCC AND VOLTAGE FREQUENCY CURVE INTERFACE: RS485
2GA3643-4P 2GA3643-4P ELEKTRON. MOTORSTEUERGERAET SIKOSTART ALS EXPERIMENTIERPL. ODER TISCHGERAET VERWENDBAR, STEUERSPEISESPG. AC 380-415 V, AC 200-240 V ODER AC 100-120 V 50/60 HZ, EINGANGSSPANNUNG LEISTUNGSTEIL 3AC 400 V, BEMESSUNGSSTROM MAX. 5.5 A, MOTORLEISTUNG MAX. 2.2KW (400V) UEBERLASTBARK.IM DAUERBETR.115% ANLAUFSTROM/MAX. ANLAUFZEIT WARM: 600%/LS, SCHNITTSTELLE RS 232
2GA3643-4R 2GA3643-4R ELECTRON.MOTOR CONTROLLING UNIT EXPERIMENTAL PANEL OR BENCHUNIT POWER SUPPLY VOLTAGE: AC 380 - 415V, AC 200 - 240V OR AC 100 - 120V 50/60HZ.INPUT VOLTAGE: POWER CIRCUIT 3AC 400V RATED CURRENT MAX. 5,5A MOTOR POWER MAX. 2,2 KW (400V) OVERLOAD CONTINUOUS 115% STARTING CURRENT / MAX.STARTING TIME WARM: 600% / LS INTERFACE RS 232
2GA3643-5B 2GA3643-5B ELECTRONIC MOTOR PROTECTION AND CONTROL DEVICE CAN BE USED AS BENCH UNIT AND EXPERIMENTAL PANEL BASIC MODUL CONTROL VOLTAGE 230V WITH INTERFACE RS 485 TO BE USED IN CONNECTION WITH 200W AND 1000W EXPERIM. MACH.
2GA3643-5C 2GA3643-5C EXPERIM. UNIT EXPENSION RACK FOR SYSTEM SIMOCODE CAN BE USED AS BENCH UNIT AND EXPERIM. PANEL WITH INPUTS AND OUTPUTS TO CONTROL CONSUMPT UNITS F.DIRECT-ON-LINE STARTING REVERSING STARTING, DAHLANDER CIRCUIT, 2 SEP. WIND. STAR-DELTA STARTING
2GA3643-5D 2GA3643-5D OPERATOR COMMUNICATION BLOCK FOR SYSTEM SIMOCODE CAN BE PLUGGED IN THE BASICUNIT 2GA36 43-5B ,WITH CONNECT. LEAD WITH CONTROL BUTTONS, TEST- AND RESETBUTTON AND VARIOUS LED'S TO INDICATE OPERATION AND MISOPERATION
2GA3643-5E 2GA3643-5E CURRENT TRANSFORMER FROM SYSTEM SIMOCODE TO BE USED WITH 200W EXP.MACH. SETTING RANGE 0,25 - 2,5A