Circuit Breaker VL630N

Showing 21-40 of 47 Products

3VL5763-1CN46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit LCD ETU42, LSIG In=630A, rated current IR=252...630A, overload protection, ISD=1.5 to 9xIR, II=10xIN short-circuit protection N protected with ground-fault protection

3VL5763-1EC46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit TM, LI In=630A, rated current IR=500...630A, overload protection, II=3250...6500A, short-circuit protection N protected

3VL5763-1EE46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 4-pole, non-auto. air circ. br. trip unit magnetic In=630A, rated current II=6500A, short-circuit protection

3VL5763-1EJ46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit TM, LI In=630A, rated current IR=500...630A, overload protection, II=3250...6500A, short-circuit protection N unprotected

3VL5763-1EM46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection TU, TM, LI In=630A, rated current IR=500...630A, overload prot. II=3150...6300A, short-circuit protection N protected (100%)

3VL5763-1LA46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU10, LI In=630A, rated current IR=252...630A, overload protection, II=1.25 to 10xIN, short-circuit protection N protected shipbuilding certificate for LRS, DNV and gL

3VL5763-1LF46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU20, LSI In=630A, rated current IR=252...630A, overload protection, ISD=1.5 to 9xIR, II=10xIN short-circuit protection N protected shipbuilding certificate for LRS, DNV and gL

3VL5763-1NA46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU10, LIN In=630A, rated current IR=252...630A, overload protection, II=1.25 to 10xIN, short-circuit protection N protected ETU communication-capable

3VL5763-1NA46-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU10, LIN In=630A, rated current IR=252...630A, overload protection, II=1.25 to 10xIN, short-circuit protection N protected without auxiliary release ETU communication-capable

3VL5763-1NB46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU10, LI In=630A, rated current IR=252...630A, overload protection, II=1.25 to 10xIN, short-circuit protection ETU communication-capable

3VL5763-1NB46-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU10, LI In=630A, rated current IR=252...630A, overload protection, II=1.25 to 10xIN, short-circuit protection without auxiliary release ETU communication-capable

3VL5763-1NE46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU20, LSI In=630A, rated current IR=252...630A, overload protection, ISD=1.5 to 9xIR, II=10xIN short-circuit protection ETU communication-capable

3VL5763-1NE46-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU20, LSI In=630A, rated current IR=252...630A, overload protection, ISD=1.5 to 9xIR, II=10xIN short-circuit protection without auxiliary release ETU communication-capable

3VL5763-1NF46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU20, LSI In=630A, rated current IR=252...630A, overload protection, ISD=1.5 to 9xIR, II=10xIN short-circuit protection N protected ETU communication-capable

3VL5763-1NF46-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU20, LSI In=630A, rated current IR=252...630A, overload protection, ISD=1.5 to 9xIR, II=10xIN short-circuit protection N protected without auxiliary release ETU communication-capable

3VL5763-1NH46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU22, LSIG In=630A, rated current IR=252...630A, overload protection, ISD=1.5 to 9xIR, II=10xIN short-circuit protection N protected ETU communication-capable

3VL5763-1NH46-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU22, LSIG In=630A, rated current IR=252...630A, overload protection, ISD=1.5 to 9xIR, II=10xIN short-circuit protection N protected without auxiliary release ETU communication-capable

3VL5763-1NN46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU12, LIG In=630A, rated current IR=252...630A, overload protection, II=1.25 to 10xIN, short-circuit protection N protected ETU communication-capable

3VL5763-1NN46-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU12, LIG In=630A, rated current IR=252...630A, overload protection, II=1.25 to 10xIN, short-circuit protection N protected without auxiliary release ETU communication-capable

3VL5763-1TA46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU10, LIN In=630A, rated current IR=252...630A, overload protection, II=1.25 to 10xIN, short-circuit protection N protected