[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit LCD ETU42, LSIG In=630A, rated current IR=252...630A, overload protection, ISD=1.5 to 9xIR, II=10xIN short-circuit protection N protected with ground-fault protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit TM, LI In=630A, rated current IR=500...630A, overload protection, II=3250...6500A, short-circuit protection N protected
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, non-auto. air circ. br. trip unit magnetic In=630A, rated current II=6500A, short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit TM, LI In=630A, rated current IR=500...630A, overload protection, II=3250...6500A, short-circuit protection N unprotected
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection TU, TM, LI In=630A, rated current IR=500...630A, overload prot. II=3150...6300A, short-circuit protection N protected (100%)
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU10, LI In=630A, rated current IR=252...630A, overload protection, II=1.25 to 10xIN, short-circuit protection N protected shipbuilding certificate for LRS, DNV and gL
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU20, LSI In=630A, rated current IR=252...630A, overload protection, ISD=1.5 to 9xIR, II=10xIN short-circuit protection N protected shipbuilding certificate for LRS, DNV and gL
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU10, LIN In=630A, rated current IR=252...630A, overload protection, II=1.25 to 10xIN, short-circuit protection N protected ETU communication-capable
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU10, LIN In=630A, rated current IR=252...630A, overload protection, II=1.25 to 10xIN, short-circuit protection N protected without auxiliary release ETU communication-capable
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU10, LI In=630A, rated current IR=252...630A, overload protection, II=1.25 to 10xIN, short-circuit protection ETU communication-capable
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU10, LI In=630A, rated current IR=252...630A, overload protection, II=1.25 to 10xIN, short-circuit protection without auxiliary release ETU communication-capable
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU20, LSI In=630A, rated current IR=252...630A, overload protection, ISD=1.5 to 9xIR, II=10xIN short-circuit protection ETU communication-capable
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU20, LSI In=630A, rated current IR=252...630A, overload protection, ISD=1.5 to 9xIR, II=10xIN short-circuit protection without auxiliary release ETU communication-capable
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU20, LSI In=630A, rated current IR=252...630A, overload protection, ISD=1.5 to 9xIR, II=10xIN short-circuit protection N protected ETU communication-capable
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU20, LSI In=630A, rated current IR=252...630A, overload protection, ISD=1.5 to 9xIR, II=10xIN short-circuit protection N protected without auxiliary release ETU communication-capable
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU22, LSIG In=630A, rated current IR=252...630A, overload protection, ISD=1.5 to 9xIR, II=10xIN short-circuit protection N protected ETU communication-capable
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU22, LSIG In=630A, rated current IR=252...630A, overload protection, ISD=1.5 to 9xIR, II=10xIN short-circuit protection N protected without auxiliary release ETU communication-capable
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU12, LIG In=630A, rated current IR=252...630A, overload protection, II=1.25 to 10xIN, short-circuit protection N protected ETU communication-capable
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU12, LIG In=630A, rated current IR=252...630A, overload protection, II=1.25 to 10xIN, short-circuit protection N protected without auxiliary release ETU communication-capable
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU10, LIN In=630A, rated current IR=252...630A, overload protection, II=1.25 to 10xIN, short-circuit protection N protected