Circuit Breaker VL400X UL

Showing 61-80 of 91 Products

3VL4860-2GD30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400X UL; TYPE LG (CAT NO. HLX3X600) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V AND 18KA//600V (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 600A, RATED CURRENT II= 1.25 TO 10 X IN, SHORT-CIRCUIT PROTECTION IR= 200-600A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL4860-2GE30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400X UL; TYPE LG (CAT NO. HLX3P600) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V AND 18KA//600V (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LSI TU= 40 DEGR. CELSIUS IN= 600A, RATED CURRENT ISD=1.5 TO 9 X IR, II=10 X IN SHORT-CIRCUIT PROTECTION IR= 200-600A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL4860-2GH30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400X UL; TYPE LG (CAT NO. HLX3U600) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V AND 18KA//600V (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 600A, RATED CURRENT ISD=1.5 TO 9 X IR, II=10 X IN SHORT-CIRCUIT PROTECTION IR= 200-600A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL4860-2JH30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400X UL; TYPE LG (CAT NO. HLX3D600) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V AND 18KA//600V (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 600A, RATED CURRENT ISD=1.25 TO 10 X IR, II=10X IN SHORT-CIRCUIT PROTECTION IR= 200-600A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL4860-2JM30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400X UL; TYPE LG (CAT NO. HLX3E600) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V AND 18KA//600V (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 600A, RATED CURRENT ISD=1.25 TO 10 X IR, II=10X IN SHORT-CIRCUIT PROTECTION IR= 200-600A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL4860-2KE30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400X UL; type LG (cat no. HLR3S600) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V and 18kA/600V (molded case switch) trip unit magnetic TA=40?C In=< 600A, rated current II=5500A short-circuit protection non-auto. air circuit breaker without connection accessories

3VL4860-2KJ30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400X UL; type LG (cat no. HLM3J600) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V and 18kA/600V (motor starter protector) trip unit magnetic TA=40?C In=< 600A, rated current II=2000...4000A short-circuit protection starter combination without connection accessories

3VL4860-2KK30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400X UL; type LG (cat no. HLM3Y600) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V and 18kA/600V (motor starter protector) trip unit magnetic TA=40?C In=< 600A, rated current II=2750..5500A short-circuit protection starter combination without connection accessories

3VL4860-2KN30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400X UL; type LG (cat no. HLX3B600) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V and 18kA/600V (molded case circuit breaker) trip unit TM, LI TA=40?C In=< 600A, rated current II=2750...5500A short-circuit protection IR=600A ETU for line protection without connection accessories

3VL4860-2PB30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400X UL; type LG (cat no. HLK3R600) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V and 18kA/600V (molded case circuit breaker) trip unit ETU, LI TA=40?C In=600A, rated current II=1.25 to 10xIN, short-circuit protection IR=200-600A ETU for line protection without connection accessories

3VL4860-2PD30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400X UL; type LG (cat no. HLK3W600) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V and 18kA/600V (molded case circuit breaker) trip unit ETU, LIG TA=40?C 3 phases/4 lines In=600A, rated current II=1.25 to 10xIN, short-circuit protection IR=200-600A ETU for line protection without connection accessories

3VL4860-2PE30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400X UL; type LG (cat no. HLK3T600) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V and 18kA/600V (molded case circuit breaker) trip unit ETU, LSI TA=40?C In=600A, rated current ISD=1.5 to 9xIR, II=10xIN short-circuit protection IR=200-600A ETU for line protection without connection accessories

3VL4860-2PH30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400X UL; type LG (cat no. HLK3V600) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V and 18kA/600V (molded case circuit breaker) trip unit ETU, LSIG TA=40?C 3 phases/4 lines In=600A, rated current ISD=1.5 to 9xIR, II=10xIN short-circuit protection IR=200-600A ETU for line protection without connection accessories

3VL4860-2VH30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400X UL type LG (cat no. HLK3A600) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole; NEMA rating 65kA/480V and 18kA/600V (molded case circuit breaker) trip unit LCD ETU, LI/LS/LSI TA=40?C In=600A, rated current ISD=1.25-10xIR, II=10xIN short-circuit protection IR=200-600A ETU for line protection without connection accessories

3VL4860-2VJ30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400X UL type LG (cat no. HLK3K600) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole; NEMA rating 65kA/480V and 18kA/600V (molded case circuit breaker) trip unit LCD ETU, LSIG-G with alarm TA=40?C 3 phases/4 lines In=600A, rated current ISD=1.25-10xIR, II=10xIN short-circuit protection IR=200-600A ETU for line protection without connection accessories

3VL4860-2VM30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400X UL type LG (cat no. HLK3G600) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole; NEMA rating 65kA/480V and 18kA/600V (molded case circuit breaker) trip unit LCD ETU, LSIG TA=40?C 3 phases/4 lines In=600A, rated current ISD=1.25-10xIR, II=10xIN short-circuit protection IR=200-600A ETU for line protection without connection accessories

3VL4860-3GB30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400X UL; TYPE LG (CAT NO. LLX3N600) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 100KA/480V AND 18KA//600V (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LI TU= 40 DEGR. CELSIUS IN= 600A, RATED CURRENT II= 1.25 TO 10 X IN, SHORT-CIRCUIT PROTECTION IR= 200-600A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL4860-3GD30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400X UL; TYPE LG (CAT NO. LLX3X600) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 100KA/480V AND 18KA//600V (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 600A, RATED CURRENT II= 1.25 TO 10 X IN, SHORT-CIRCUIT PROTECTION IR= 200-600A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL4860-3GE30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400X UL; TYPE LG (CAT NO. LLX3P600) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 100KA/480V AND 18KA//600V (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LSI TU= 40 DEGR. CELSIUS IN= 600A, RATED CURRENT ISD=1.5 TO 9 X IR, II=10 X IN SHORT-CIRCUIT PROTECTION IR= 200-600A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL4860-3GH30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400X UL; TYPE LG (CAT NO. LLX3U600) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 100KA/480V AND 18KA//600V (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 600A, RATED CURRENT ISD=1.5 TO 9 X IR, II=10 X IN SHORT-CIRCUIT PROTECTION IR= 200-600A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES