• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.

Circuit Breaker VL160L

Showing 341-356 of 356 Products

3VL2716-3TH43-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection Electronic Trip Unit ETU22, LSIG In=160A, rated current IR=64...160A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected

3VL2716-3TH43-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection Electronic Trip Unit ETU22, LSIG In=160A, rated current IR=64...160A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected without auxiliary release

3VL2716-3TH46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection Electronic Trip Unit ETU22, LSIG In=160A, rated current IR=64...160A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected with screw terminals

3VL2716-3TH46-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection Electronic Trip Unit ETU22, LSIG In=160A, rated current IR=64...160A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected with screw terminals without auxiliary release

3VL2716-3TN43-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection Electronic Trip Unit ETU12, LIG In=160A, rated current IR=64...160A, overload protection, II=1.25 to 11xIN, short-circuit protection N protected

3VL2716-3TN43-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection Electronic Trip Unit ETU12, LIG In=160A, rated current IR=64...160A, overload protection, II=1.25 to 11xIN, short-circuit protection N protected without auxiliary release

3VL2716-3TN46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection Electronic Trip Unit ETU12, LIG In=160A, rated current IR=64...160A, overload protection, II=1.25 to 11xIN, short-circuit protection N protected with screw terminals

3VL2716-3TN46-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection Electronic Trip Unit ETU12, LIG In=160A, rated current IR=64...160A, overload protection, II=1.25 to 11xIN, short-circuit protection N protected with screw terminals without auxiliary release

3VL2716-3UJ43-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection Electronic Trip Unit LCD ETU40, LI/LS/LSI In=160A, rated current IR=64...160A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected

3VL2716-3UJ43-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection Electronic Trip Unit LCD ETU40, LI/LS/LSI In=160A, rated current IR=64...160A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected without auxiliary release

3VL2716-3UJ46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection Electronic Trip Unit LCD ETU40, LI/LS/LSI In=160A, rated current IR=64...160A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected with screw terminals

3VL2716-3UJ46-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection Electronic Trip Unit LCD ETU40, LI/LS/LSI In=160A, rated current IR=64...160A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected with screw terminals without auxiliary release

3VL2716-3UN43-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection Electronic Trip Unit LCD ETU42, LSIG In=160A, rated current IR=64...160A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected with ground-fault protection

3VL2716-3UN43-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection Electronic Trip Unit LCD ETU42, LSIG In=160A, rated current IR=64...160A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected with ground-fault protection without auxiliary release

3VL2716-3UN46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection Electronic Trip Unit LCD ETU42, LSIG In=160A, rated current IR=64...160A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected with screw terminals

3VL2716-3UN46-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection Electronic Trip Unit LCD ETU42, LSIG In=160A, rated current IR=64...160A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected with screw terminals without auxiliary release