[Add to Enquire List] [Remove from Inquiry List]connection cable between residual current device RCD820 and electronic trip unit (ETU) circuit breaker 3VA2 spare part
[Add to Enquire List] [Remove from Inquiry List]Operating Unit w/ Bowdencable Max-Flex Operator handle only Handle steel, plastic NEMA 1, 12, 3R black=OFF, red=ON
[Add to Enquire List] [Remove from Inquiry List]Operating Unit w/ Bowdencable Max-Flex Operator handle only Handle steel, epoxy coated NEMA 1, 12, 3R black=OFF, red=ON
[Add to Enquire List] [Remove from Inquiry List]Operating Unit w/ Bowdencable Max-Flex Operator handle only Handle steel, epoxy coated NEMA 1, 12, 3R black=OFF, black=ON
[Add to Enquire List] [Remove from Inquiry List]Operating Unit w/ Bowdencable Max-Flex Operator handle only Handle steel, chrome plated NEMA 4/4X black=OFF, red=ON
[Add to Enquire List] [Remove from Inquiry List]Operating Unit w/ Bowdencable Max-Flex Operator handle only Handle steel, chrome plated NEMA 4/4X black=OFF, black=ON
[Add to Enquire List] [Remove from Inquiry List]fixed-mounted molded case circuit breaker w. handle frame 1600; 4AUX and trip alarm switch S24; Icu "H" Icu=85kA @ 415V, 3-pole ETU350, LSI, In=1600A rotary coding switch Ir=640...1600A Isd=1...10xIn, Ii=1.5...15xIn N conductor protec. adjustable opt. w. ext. CT; up to 200% straight bus connector extended No communication connection, no measurement function With trip alarm switch TAS and trip alarm switch S25 With mechanical calling without 2nd auxiliary release With 1st auxiliary release, ST Shunt release 220-240 V AC/DC
[Add to Enquire List] [Remove from Inquiry List]fixed-mounted molded case circuit breaker w. handle frame 1600; 4AUX and trip alarm switch S24; Icu "M" Icu=55kA @ 415V, 3-pole ETU320, LI, In=1250A rotary coding switch Ir=500...1250A Ii=1.5...15 x In N conductor protec. adjustable opt. w. ext. CT; up to 200% nut keeper kit No communication connection, no measurement function Without additional alarm switch assembly With mechanical calling without 2nd auxiliary release without 1st auxiliary release
[Add to Enquire List] [Remove from Inquiry List]fixed-mounted sw. disconnector with handle frame 1600; 4AUX Icu=55kA @ 415V, 3-pole SD100; In=1250A without overload protection w/o short-circuit protection nut keeper kit No communication connection, no measurement function Without additional alarm switch assembly With mechanical calling with 2nd auxiliary release UVR, instant Undervoltage 24 V AC/DC without 1st auxiliary release
[Add to Enquire List] [Remove from Inquiry List]fixed-mounted molded case circuit breaker w. handle frame 1600; 4AUX and trip alarm switch S24; Icu "H" Icu=85kA @ 415V, 3-pole ETU320, LI, In=1250A rotary coding switch Ir=500...1250A Ii=1.5...15 x In N conductor protec. adjustable opt. w. ext. CT; up to 200% nut keeper kit No communication connection, no measurement function Without additional alarm switch assembly With mechanical calling without 2nd auxiliary release without 1st auxiliary release
[Add to Enquire List] [Remove from Inquiry List]circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=160A overload protection Ir=63A...160A short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In nut keeper kit circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU350, LSI, In=160A overload protection Ir=63A...160A short-circuit protection Isd=1.5...10 x Ir, UNDERVOLTAGE RELEASE 208-230 V AC 50/60 HZ ACCESSORY FOR 3VA1 3 AUXILIARY SWITCH CHANGEOVER H